ECM AFM1040 Instruction Manual page 27

Air-fuel ratio combustion monitor
Table of Contents

Advertisement

AFM1540.EXE 1.2 Eeprom Programming Software (AFM1540 Only)
AFMs are delivered programmed to use one of the following sensors: Bosch LSU 4.9, LSU
4.2, or NTK UEGO. This is indicated on the AFM's label. The AFM1540 can be user-
reprogrammed to use any one of these sensors. PC software routine AFM1540.EXE is
supplied with the AFM1540 to facilitate this.
another sensor, indicate on the AFM's label which sensor it is programmed for.
* Using the wrong programming with the wrong sensor will result in sensor damage. *
Minimum system requirements:
• Windows 95 or higher
Serial communication port (COM1 with DB9 connector)
Installing the software:
• Copy all files on the floppy disk to a folder (all files must reside in the same folder)
Operation:
1. Close all active program windows on the PC.
2. Connect the SMB/PC cable (P/N 1500A-16) from the SMB/PC connector on the AFM to
the COM1 port on the PC. Only one AFM can be programmed at a time. Do not connect
other AFM units using the SMB/PWR cables to the AFM being programmed. A sensor
does not have to be attached and ignore any lights on the AFM.
3. Turn the AFM1540's power switch "off" and connect power (12 to 28 VDC) to the
AFM1540's wiring harness (P/N 1002A-3x).
4. Double click on the AFM1540 icon ("AFM1540").
5. Carefully follow the program instructions. There are several steps.
6. The program requires the user enter a .txt filename as follows:
lsu49.txt (to program the AFM1540 for a Bosch LSU 4.9 sensor)
lsu42.txt (to program the AFM1540 for a Bosch LSU 4.2 sensor)
tl6312.txt (to program the AFM1540 for an NTK TL6312 sensor)
7. When finished programming, close the window.
After reprogramming the AFM1540 to use
23