Download Print this page

Prepare To Install - Graco DataTrak 24A575 Installation And Parts

Advertisement

Prepare to Install

1. Relieve the pressure. Follow instructions in your
spray package manual.
2. Disconnect the air line to the motor.
Install the Kit
1. Remove the insert
from the air control
panel.
2. Install the DataTrak
module (1) on the
air control panel.
Use the hose clips
(4) provided to
attach the Data-
Trak cable to the
pump air line.
3. Models 24A575 and 24A576 only: Attach the sole-
noid (2a) and bracket (2d) to the air valve. Use the
same screws (2c) that attach the air valve to the
manifold, as shown.
2c
2d
313541C
1
4
ti13533a
2a
ti13534a
4. Use the screw provided to attach the reed switch
just behind the air inlet. Remove the muffler, if
needed, for easier access. Rotate the air inlet fitting
as needed so the wrench flat clears the reed switch.
5. Connect the DataTrak cable to the 5-pin connector
on the reed switch. Reconnect the air line to the
motor.
Prepare to Install
NOTE: Model
24A592 has no
solenoid
attached to the
reed switch.
ti13535a
air line
ti13555a
5-pin
connector
3

Advertisement

loading

This manual is also suitable for:

Datatrak 24a576Datatrak 24a592Datatrak 24b564Datatrak 24b565Datatrak 24b566