Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: MS90E – MS400E and MSSUPER1E – 3E ____________________ ____________________ IMPORTANT: Leave this material with the home owner. steam ® Feel Good Inc. ®...
R E A D M E F I R S T ! When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: As you follow these instruc- tions, you will notice warning and caution sym- IMPORTANT SAFETY INSTRUCTIONS bols.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SELECT YOUR MrSteam In considering the purchase or MrSteam @ Your Fingertips: use of this steambath system, please note that if you are pregnant, have a coronary condition, are Start working smarter with MrSteam’s mobile sizing app, in poor health, are being treated for any other now available for the iPad , iPod...
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ BEFORE INSTALLING volume and construction. If any questions, please refer to MrSteam sizing and selection guide on page 3. Carefully inspect the Steam Generator and packaging for shipping damage. In the event of shipping damage, 3.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ RECOMMENDED FEEDWATER WATER QUALITY INFORMATION QUALITY or optimum results, the water supply should be tested prior to installation. If the Hardness, ppm 8 – 85 (~0.5 – 5 gpg) mineral content exceeds the following recommended limits, various external treat- P-Alkalinity, ppm 85 –...
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ TYPICAL MrSteam INSTALLATION Drawings for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details. Provide unions as required The control features an to facilitate installation and integral temperature sensor.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ TYPICAL MULTI-INSTALLATION INSTRUCTIONS (shown with optional AutoFlush) 1. Install each steam generator as in a single installation. Install generators as close as practical to each other, not exceeding 10 feet. The intercon- necting cable length is 12 feet.
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ INSTALLATION STEAM PIPING ( ⁄ " NPT) PLUMBING 1. DO NOT install any valve in steam piping. Flow of steam must All plumbing shall be performed by a qualified licensed plumber be unobstructed.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ INSTALLING THE ROUND OR SQUARE 1/8" minimum clearance required ( 1 ⁄2" NPT) AROMASTEAM STEAMHEAD when Acrylic Shield is used. See installation instructions provided Use Teflon ® with the Acrylic Shield. equal sealant on ⁄...
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ GENERATOR DIAGRAM Water Inlet Control & Accessory Connections Steam Outlet Safety Valve Optional AutoFlush Manual Drain Valve IMPORTANT NOTES: Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ E L E C T R I C A L C H A R T ________________________________________________________________________________________________________ ELECTRICAL Max Room Wire Size Wire Size † Model No. (Cu. Ft.*) Volts Phase Amps (AWG)for 40˚...
Page 13
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ SINGLE PHASE 208/240 VOLT WIRING DIAGRAMS POWER INPUT L E G E N D TRANSFORMER (All Diagrams) FIELD MODELS MS90E, MS150E, WIRING FACTORY MS225E, MS400E WIRING WATER FEED SOLENOID GROUND VALVE HEATER CONTACTOR...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ MULTI-INSTALLATION INSTRUCTIONS 1. Install each unit as in a single installation. Install the two generators as close to each other as possible. Shock Hazard. Power must be disconnected at the main electrical supply before removing steam generator covers.
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ INITIAL START-UP AND CHECKOUT 1. Turn on control. Follow specific instructions provided with controls. 2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head. Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ SYSTEM STATUS CODES The control (either iSteam ® , AirTempo ® , iTempo or iTempo/Plus ) may display a status code if the steam generator is not functioning ® ® properly.
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ ® OPTIONAL AUTOFLUSH Steam Generator Box Contents 3 Pin Connector for AutoFlush AutoFlush Valve with Cord Installation Instructions. OPERATION The optional AutoFlush System feature automatically drains the MrSteam generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ OPTIONAL CONDENSATION PAN MrSteam strongly recommends the use of a conden- sation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensa- tion pan.
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ CONTROL INSTALLATION Refer to ontrol Manual for specific installation requirements BEFORE INSTALLING DO NOT route iSteam, AirTempo, iTempo/Plus, Turn power to the steam generator OFF before connecting the iTempo, HomeWizard or iGenie control wiring inside conduit control to the generator.
mr . steam ® Installation, Operation & Maintenance Manual mr . steam __________________________________________________________________________ ® Installation, Operation & Maintenance Manual __________________________________________________________________________ H O M E O W N E R S E C T I O N When using this steam bath equipment, basic safety precautions should always R E A D M E F I R S T ! be followed, including the following: As you follow these instruc-...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ CARE TIPS FOR ALL CONTROLS AND SETTING THE STEAM BATH TEMPERATURE AND DURATION STEAMHEADS 1. Use only mild soap and water on a soft cloth to clean Set the steam bathing temperature the control and steamhead.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ USING MrSteam ESSENTIAL OILS njoy AromaSteam essential oils by placing a drop or two AromaSteam into an unheated AromaSteam steamhead as shown in the 10ml bottle illustration. Only use MrSteam AromaSteam essential oils in with integrated the MrSteam AromaSteam steamhead.
Need help?
Do you have a question about the mr. steam MS90E and is the answer not in the manual?
Questions and answers