READ ME FIRST! When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: As you follow these instruc- IMPORTANT SAFETY INSTRUCTIONS tions, you will notice warning and caution symbols. This blocked information is impor- tant for the safe and efficient installation and READ AND FOLLOW ALL INSTRUCTIONS operation of this generator.
CX SERIES Installation, Operating & Maintenance Manual IMPORTANT SAFETY INFORMATION Read these instructions before Prolonged use of the steam system installation, operation or service. can raise excessively the internal human body temperature and impair the body’s ability to regulate Never use damaged equipment, its internal temperature (hyperthermia).
CX SERIES Installation, Operating & Maintenance Manual IMPORTANT SAFETY INFORMATION This document contains important safety, The wet surfaces of steam enclosures operation and maintenance information. Leave this may be slippery. Use care when entering or leaving. To document with the owner. Do not discard this prevent slip and fall hazards non-slip strips or non-slip document.
CX SERIES Installation, Operating & Maintenance Manual LOCATING THE STEAM GENERATOR Do not run any control wiring inside Do not hang the CX steam generator on conduit together with power lines or close to hot a wall. Hanging the CX generator on a wall may result water or steam piping.
CX SERIES Installation, Operating & Maintenance Manual 21” Min. Ceiling Height Clearance Area 0” Min. Provide a minimum of 12 inches of clearance as required for steam piping, drain, AutoFlush, water feed and pressure relief plumbing PLUMBING General Water supply and steam piping must All plumbing shall be performed by a qualified licensed plumber and in accordance with be flushed to remove flux and other debris prior to...
CX SERIES Installation, Operating & Maintenance Manual WATER SUPPLY (3⁄8" NPT) DRAIN (1" NPT) Install a shut off valve in the water supply Do not connect the generator drain line line. to an undersink trap. It is recommended to install a strainer in Do not drain into a steam enclosure or the water supply line.
CX SERIES Installation, Operating & Maintenance Manual STEAM PIPING (3/4" NPT) External Connections Terminal Block Union Safety Valve STEAM ROOM STEAM GENERATOR Steam Outlet Manual Drain ” Valve Steam Piping Fitting Note: Some CX systems have multiple generators. SteamHead Each steam generator must be plumbed separately AutoFlush to a dedicated steam line and dedicated steamhead.
CX SERIES Installation, Operating & Maintenance Manual Failure to pitch the steam piping as required for STEAMHEAD INSTALLATION condensate to drain, may cause condensate to block • For steam rooms constructed of tile, marble or the flow of steam. Blocking the steam flow may cause similar non-porous heat-resistant materials for the steam pressure to discharge boiling water through the enclosure, locate steamhead 12 inches above steam...
CX SERIES Installation, Operating & Maintenance Manual ACRYLIC SHIELD Apply a small bead of silicone in the grooves on the top and bottom of the steamhead. Place an Acrylic Shield (PN 103985) over the steamhead until the tabs engage the grooves in the steamhead. Do not use with fragrance containing aldehydes.
CX SERIES Installation, Operating & Maintenance Manual CONTROL MOUNTING GENERATOR ELECTRICAL • Select the mounting plate or box for either flush or • Connect power wiring to main terminal block. surface mounting respectfully. • Open the Terminal cover on the right side of the generator.
CX SERIES Installation, Operating & Maintenance Manual Electrical Chart Never use damaged equipment, doing so may result in an inoperative or hazardous installation. Wire size (AWG) Room Model Volts Phase Amps Volume (FT3) for 25°C All electrical wiring installation to be performed by a CX0360 Up to 360 qualified licensed electrician in...
CX SERIES Installation, Operating & Maintenance Manual CONTROL DIMENSIONS 5.315 1.583 1.874 7.087 Power Connection Ethernet Connection TEMPERATURE SENSOR INSTALLATION DIAGRAM A • Locate sensor on a wall inside the steam room five (5) feet above the Silicone Sealant 1" hole floor.
CX SERIES Installation, Operating & Maintenance Manual 30 MINUTE ROOM TIMER The 30 minute timer provides guests in the steam room an EXTERNAL TERMINAL CONNECTIONS accurate and easy way to safely time their steam sessions. It is available as a Digital (104560) or Mechanical (CU-99216B) timer. •...
CX SERIES Installation, Operating & Maintenance Manual REPLACEMENT PARTS LIST PART No. DESCRIPTION Generator 103036 Manual Drain Valve ALL MODELS 99297 Safety Valve 15PSI ALL MODELS CX81500 CX AutoFlush ALL MODELS 104423 Liquid Level Probe - Low Water ALL MODELS 90229-1 Liquid Level Probe - High Water ALL MODELS...
CX SERIES Installation, Operating & Maintenance Manual IP ADDRESS ASSIGNMENT Each generator needs to be assigned an IP address by the CONTROL. Single Generator System 1. Take the provided ethernet cable and connect it to the ethernet port on the right side of the generator as well as the ethernet port on the bottom of the CONTROL.
CX SERIES Installation, Operating & Maintenance Manual PROGRAMMING 1. On the main page, tap the three horizontal line button in the upper left corner. 2. On the menu that comes up, select “Date\Time”. 3. Adjust the date and time as necessary. 4.
CX SERIES Installation, Operating & Maintenance Manual ADDITIONAL FEATURES Main Page The generator can be manually started or stopped on this page. This button will also override any presets. Status Page This screen shows the status of generator and the steam room itself.
Page 23
CX SERIES Installation, Operating & Maintenance Manual ADDITIONAL FEATURES Settings Page Some settings specific to the CONTROL can be set from this page. The aligns with the cleaning time. This feature disables the touch screen for that period of time so it can be cleaned. The recalibrates the touch screen.
CX SERIES Installation, Operating & Maintenance Manual TROUBLESHOOTING Applies to 1-2 1. Electric shock hazard. MrSteam steam generators are connected to high voltage and contain live electrical components. All installation and service to be performed by qualified and licensed electricians only.
CX SERIES Installation, Operating & Maintenance Manual TROUBLESHOOTING GUIDE FAULTY WATER FEED SOLENOID & HEATING ELEMENT ERROR PROBABLE CAUSE SUGGESTED REMEDY Emergency Stop Is Active The emergency stop button Disengage emergency stop switch has been pressed Steam Unit X: There is an issue with the ethernet Check to make sure the Communication to CONTROL cables or their connections...
Page 26
® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at 1.800.767.8326 (East Coast) or 1.800.727.8326 (West Coast) for more information. ® hello@mrsteam.com • www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 1.800.76.STEAM 9410 S.