  • Page 1 User manual for FCL-600 underwater lamps for aquaculture...
  • Page 2 Notice We make every effort to provide the latest NORBIT Subsea AS technical documentation. There may be Stiklestadveien 1 updates. For this, please contact NORBIT 7041 Trondheim Support for the latest information. Norway Copyright Statement Phone: +47 739 82 569 Copyright 2024 by NORBIT.
  • Page 3: Table Of Contents

    Who to use the this user manual ..................7 About NORBIT Aqua ......................8 Technology for sustainable biology .................... 8 Our Mission ..........................8 About NORBIT Aqua FCL-600 ..................8 About the Power Distribution Cabinet (PDC) ..............10 Mounting ........................... 11 Delivery Content ......................11 Preparations before mounting on the cage/cage ............
  • Page 4: Safety

    All individuals tasked with operating NORBIT Aqua's underwater lights must be thoroughly trained on the proper use of the equipment and made aware of the risks associated with misuse. NORBIT is not responsible for either injury or damages misuse of the lights due to improper use.
  • Page 5: Safety Equipment

    The owner and operations manager are responsible for ensuring that all employees have read and understood the contents of this user manual before installation. Tasks not mentioned in this user manual must be carried out by NORBIT service personnel or after possible written approval from NORBIT.
  • Page 6 This entire user manual must be read and understood before any work with the equipment is started, and it must be used as a guide during installation, use and maintenance. TN-240027-1 NORBIT Aqua FCL600 User manual Page 6 of 19...
  • Page 7: Information

    Keep this user manual as long as your NORBIT Aqua underwater lights are in use and note all changes to/on the equipment at the back of the manual as they are made. An updated version of this manual can always be found at the following address: https://norbit.com/no/products-and-solutions/...
  • Page 8: About Norbit Aqua

    About NORBIT Aqua NORBIT Aqua has a long history as manufacturers of underwater lamps, with thousands of units in use by breeders in Norway and internationally. We have broad expertise in lighting for fish farming and work hard to be a preferred partner for our customers in terms of technical solutions, professional expertise, and service within cage-based and land-based farming.
  • Page 9 NORBIT Aqua FCL-600 Description TN-240027-1 NORBIT Aqua FCL600 User manual Page 9 of 19...
  • Page 10: About The Power Distribution Cabinet (Pdc)

    The control cabinet is the lamps' control unit and power supply. It is mounted under the handrail and weighs approx. 17kg. One person can assemble the control cabinet, but NORBIT Aqua recommends that two people participate in the assembly process.
  • Page 11: Mounting

    Before bringing lamps and PDC out onto the edge of the cage, it is recommended to make some preparations. A recommended lighting setup when using the NORBIT FCL600 is 4 lamps per cage (157-meters in circumference) powered by two PDCs. Since each PDC drives two lamps (Figure 1), power access to two PDCs is needed.
  • Page 12 Please note that any treatment of electrical equipment carries a risk of electric shock. When working in and around water, this is particularly risky. Therefore, always use insulating gloves and footwear when working with electrical equipment. Personal Protective Equipment! TN-240027-1 NORBIT Aqua FCL600 User manual Page 12 of 19...
  • Page 13: Placement And Suspension Of The Lamps

    Figure 9. Suggestions for placing lamps in pens. Figure 10. Correct suspension of the FCL-600 Suspension of the lamps The lamps are suspended using a rope loop attached to the two eyebolts at the top of the lamp (Figure 10).
  • Page 14 The lamps must be hung so far inside the cage that they do not come into contact with the mesh bag. Warning! To avoid overheating and potential damage to the lamp, connect the power after immersing the lamp in the water. Warning! Improper suspension may invalidate the warranty. TN-240027-1 NORBIT Aqua FCL600 User manual Page 14 of 19...
  • Page 15: Service Og Vedlikehold

    This maintenance must be carried out regularly, and the lamps are taken out of the water for checking and possibly cleaning. NORBIT recommends cleaning at least once per month and even more frequently during the summer months when algae and vegetation growth are at their peak.
  • Page 16: Generelt

    PDF format, as well as an installation video for the lamp and control cabinet. Regular maintenance Attention! Sign for work done AFTER it has been done. Date ID-nr. lamp Performed maintenance Signature TN-240027-1 NORBIT Aqua FCL600 User manual Page 16 of 19...
  • Page 17 The product is to be regarded as inert and can be placed at an approved waste site and recycled within the category EE waste. NORBIT Aqua will accept lamps and control cabinets at the end of their useful lives for safe disposal. TN-240027-1 NORBIT Aqua...
  • Page 18: Avhending

    Number: Unit: Producer: Prod. No.: Purchased (year): Deviation description: Suggestions for follow-up: Date and signature, reporting: Performed follow-up: Status: New action on notice of deviation no. Date and signature, follow-up: TN-240027-1 NORBIT Aqua FCL600 User manual Page 18 of 19...
  • Page 19: Vedlegg A - Avviksskjema

    Appendix B – Contact information NORBIT Aqua AS Stiklestadveien 1 7041 Trondheim Support: support.aqua@norbit.com TN-240027-1 NORBIT Aqua FCL600 User manual Page 19 of 19...