Precision E/One Extreme Series Installation Instructions Manual

Precision E/One Extreme Series Installation Instructions Manual

Simplex, duplex, triplex & quadplex stations
Hide thumbs Also See for E/One Extreme Series:

Advertisement

Quick Links

W-SERIES
FIBERGLASS
TYPICAL
INSTALLATION
INSTRUCTIONS
& WARRANTY
INFORMATION
SIMPLEX, DUPLEX, TRIPLEX &
QUADPLEX STATIONS
1

Advertisement

loading

Summary of Contents for Precision E/One Extreme Series

  • Page 1 W-SERIES FIBERGLASS TYPICAL INSTALLATION INSTRUCTIONS & WARRANTY INFORMATION SIMPLEX, DUPLEX, TRIPLEX & QUADPLEX STATIONS...
  • Page 2 Environment One Grinder Pump Feature Identification 1. Electrical Quick Disconnect (EQD) – Electrical lead from pump core terminates here (NEMA 6P). 2. Power and Alarm Lead – Circuits to be installed in accordance with local codes. 3. Alarm Panel – Rainproof (NEMA 4X) enclosure. Equipped with circuit breakers. Locate according to local codes.
  • Page 3 1 - 4 in SEAL CONDUIT PER NEC SECTION 6-12 INCH 300.5 & 300.7 SETTLING LOOP 5 x2 Figure 1 FAILURE TO COMPLY WITH INSTALLATION INSTRUCTIONS WILL VOID WARRANTY...
  • Page 4 TYPICAL MULTI- PUMP STATIONS: DUPLEX, TRIPLEX & QUADPLEX Simplex 1 Simplex Panel Duplex 1 Duplex Panel Triplex 1 Simplex Panel, 1 Duplex Panel Quadplex 1 Quadplex Panel...
  • Page 5 pipe must be a minimum This is a sewage handling the excavated hole using the pump and must be vented in of 30 inches from bottom lifting hooks. Do not lift the accordance with local plumbing of the tank. The slope of the tank by any of the fiberglass surfaces if precast ballast is codes.
  • Page 6 require the use of additional properly. organic material may be used if sealant or adhesives. Other 5. Vent Installation A compacted in lifts not to exceed grommet sizes are available fiberglass station is supplied one foot. It must be compacted upon request.
  • Page 7 Figure 4 Figure 3 Power at the station must not drop more than 10% below the nameplate voltage. Maximum Recommended Length: 120 Volt 60’ (min. voltage at pump — 108V) 240 Volt 150’ (min. voltage at pump — 216V) Figure 5 Consult factory for longer lengths dedicated 30-amp breaker with contained within suitable...
  • Page 8 Figure 7 Figure 8 Figure 9 The supply cable terminates the top of the tank; the cord grip until the metal cable in a convenient, electrical portion of the cable with stop rests against the cord grip quick-disconnect (EQD) plug less then 24”...
  • Page 9 be utilized where 24” of soil assembly to open. (Fig. 9) Power source to the panel cover cannot be maintained. Hang power cable, breather must be 240 VAC (or 120 VAC 10. Stand Assembly (Fig. 4) tubing with Equalizer, and for a 120V model).
  • Page 10 Check voltage from Clear/Reset the alarm the main power supply. The panel: voltage must be within 10% • Sentry panels: Reset is of the nameplate voltage (i.e. not required. 240=216 to 264 and 120=108 • Protect Panel: Turn to 132). Note the voltage. pump and alarm Verify the panel wiring breakers off and back on...
  • Page 11 Grinder Pump Station Ballast Calculations Any buried vessel that is submerged, or partially submerged, in water will be acted on by an upward buoyant force that attempts to return the vessel to a non-submerged state. The magnitude of this buoyant force is equal to the volume of the vessel that is submerged multiplied by the density of water.
  • Page 12 Chart 2 *Ballast is calculated with ground water at grade STATION CONCRETE WEIGHT STATION STATION DIAMETER CONCRETE CONCRETE STATION DIAMETER (pounds) VOLUME BUOYANT BALLAST MODEL MATERIAL HEIGHT (inches) VOLUME WEIGHT TYPE (inches) station, (cubic FORCE FORCE (inches) (ballast 10" (cubic feet) (pounds) cover, feet)
  • Page 14 A Precision Castparts Company Environment One Corporation 2773 Balltown Road Niskayuna, New York 12309–1090 Voice: (01) 518.346.6161 Fax: 518.346.6188 www.eone.com NA0067P02 Rev A 2/24...
  • Page 15: General Information

    User Instructions for the Environment One Grinder Pump General Information Your home is served by a low pressure sewer system; the key element is an Environment One grinder pump. The tank collects all solid materials and wastewater from the house. The solid materials are then ground to a small size suitable for pumping as a slurry with the wastewater.
  • Page 16: Limited Warranty

    E/One Sewers Limited Warranty For E/One Extreme D-Series, W-Series & Upgrade Environment One Corporation offers a limited warranty that guarantees its product to be free from defects in material and factory workmanship for a period of two years from the date of installation, or 27 months from the date of shipment, whichever occurs first, provided the product is properly installed,...