Product Overview; Operation - D'Orly CUPRO 3D User Manual

Self leveling laser
Table of Contents

Advertisement

Available languages

Available languages

PRODUCT OVERVIEW

Vertical Laser
Vertical Laser
Horizontal Laser
Vertical Laser
Vertical Laser
4

OPERATION

Only move the CUPRO laser in the "OFF" state. (3) This locks the laser emitters
in their place and prevents damage or decalibration as a result of excessive
movement.
1) (Optional) Fix the Cupro laser to the desired accessory, such as a tripod or
magnetic bracket. Make sure the connection is secure and the placement is
reliable.
2) Move the instrument as close to the desired position as possible, as close to
level as possible.
3) Turn on the instrument using the ON/OFF switch. (3) The instrument will
auto-level within 2,5°. If the placement deviates more than 2,5° from level
the laserbeams will keep fl ashing.
4) Turn on the desired laser emitters by pressing the "V" or "H" buttons. (2)
Pressing the "V" button multiple times switches between the on/o states of
each vertical laser beam. Pressing the "H" button multiple times switches
the horizontal laser beam on or o .
5) Micro-adjustments can be made in the ON-state by carefully moving the
instrument a few millimeters in place.
DETECTOR
1) When using an optional laser detector the working range can be doubled.
Switching on the detector function on the control panel (3) will activate
the high frequency pulse needed for detection. This cannot be detected
with the naked eye, the laserbeams will look less bright.
TILT FUNCTION
The tilt function enables the instrument to emit laser beams in an angled
position. To use the tilt function:
1) Keep the "ON/OFF" switch in the "OFF" position. (3)
2) Press the "Lock" button on the control panel. (2)
3) Enable the desired laser emitters by pressing the corresponding buttons on
the control panel.
4) To switch o the device press the "Lock" button again.