  • Page 1 Z-Wave™ Multi Sensor FGT-0002 User’s Guide Rev. 1.01 MITSUMI ELECTRIC CO., LTD.
  • Page 2 Introduction This product is "FGT-0002" that detects and notifies motion, temperature, humidity, and illuminance that support Z-Wave Plus™ as standard. Detects changes in the state of the place where the product is installed and notifies the controller. This devices is a security enables Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.
  • Page 3 ■Installation by Operation SW ◇Preparation of this product Remove the Battery cover and insert the battery. Operation SW ◇Connection with controller 1 Set the controller in "Add (Inclusion)" mode. (For the operation procedure, see the instruction manual of the controller.) 2 Push the Operation switch once and release it immediately.
  • Page 4 Other operations ■Battery replacement 1 Remove the Battery cover. 2 Remove the Battery and insert a new one. ※Insert the battery in the correct direction. 3 Attach the Battery cover 4 Put in the original place ■Remove (Excursion) 1 Remove the Battery cover. 2 Set the controller in "Remove (Exclusion)"...
  • Page 5 Z-Wave Overview Z-Wave+ Product Info ・Manufacturer: MITSUMI ・Z-Wave Device Type: Multi Sensor Reachable Sleeping Slave ・Z-Wave Role Type: (RSS) ・Product ID: 0x0001 ・Product Type ID: 0x0016 Supported Command Classes Command Class List (Security: None) ・COMMAND_CLASS_ZWAVEPLUS_INFO ・COMMAND_CLASS_TRANSPORT_SERVICE ・COMMAND_CLASS_SECURITY_2 ・COMMAND_CLASS_SUPERVISION Command Class List (Security: S2) ・COMMAND_CLASS_ASSOCIATION...
  • Page 6 On time within an On/Off period MANUFACTURER SPECIFIC Upon receiving a Manufacturer Specific Get request, it returns a Manufacturer Specific Report. Value Comment Manufacturer ID 0x0112 MITSUMI Product Type ID 0x0016 Multi Sensor Product ID 0x0001 Multi Sensor Vol.1 NOTIFICATION Sends the reaction of the motion sensor to the controller.
  • Page 7 CONFIGURATION Set and check the configuration parameters to control this product. Parameter Number 1 Configuration Set request sets the measurement interval for the sensor. (The default value is 3 minutes.) Size = 2 Configuration Value1 = 0x0001 … 1 minute …...
  • Page 8 Parameter Number 5 Configuration Set request sets the amount of change that the illuminance sensor notifies the controller. (The default value is 10%.) Size = 1 Configuration Value1 = 0x01 … 1% … 0x32 … 50% Configuration Get request reports the amount of change that the illuminance sensor notifies the controller. Configuration Value1 = 0x01 …...