ELECTRICAL CONNECTION MT-150 WITH
The extractor unit should be connected to a single phase supply network at the voltage and frequency
indicated on the extractor characteristics plate.
The electrical installation must be fitted with a single-pole switch with a distance between contacts of at
least 3 mm.
1) Loosen the screw (A) and remove the cover (B).
2) Perforate the plug (C) and thread the power cables through the hole.
3) Connect the power cables to the terminals fo the connection strip (D) and, once connected fix it firmly
between the pivots (E).
4) Insert the plug (C) in the hole between the housing (F) and the cover (B).
5) Replace the cover (B) and fix it in place using the screw (A).
The appliance must be permanently connected to a fixed electrical supply installation using twin conductor
cable of at least 1 mm
in section and a maximum of 1.5 mm
.
2
2
No earth installation is required as the appliance has double insulation. (Class II).
IPX2
Type MT-150 TIMER:
IPX2
To adjust the timer, turn the pivot (4) in a clockwise direction to increase the timer time.