Installation Procedure - Yamaha ICP1 Owner's Manual

Intelligent control panel
Hide thumbs Also See for ICP1:
Table of Contents

Advertisement

J
J
J
J

Installation Procedure

Connection
2
To network hub or
DME64N/24N.
1
Connect the control panel unit and the ICP1 adaptor box.
Use an Ethernet "straight" cable.
• Do not use a "cross" cable to connect the control panel unit
and adaptor box. Also do not use joint connectors, cross cable
converters, or other extension adaptors.
WARNING
• Connect ct the control panel unit and adaptor box directly, not
via a hub
.
• For maximum safety be sure to securely connect the ICP1
CAUTION
earth screw to an earth connection .
2
Connect the adaptor box to a network hub or the DME64N/24N.
Use a "straight" cable for connection to a hub, or a "cross" cable for direct connection to the DME64N/24N.
n
• Use a 100Base-TX/10Base-T switching hub.
• When using category 5 UTP (Unshielded Twisted Pair) cable, the total length of the cables
connecting the control panel unit to the hub or DME64N/24N can be up to 100 meters. Due to
differences in cable and switching hub performance, however, proper operation at the maximum
length cannot be guaranteed in some cases. The maximum usable cable length will also be
reduced if joint connectors, cross cable converters, or other extension adaptors are used.
• Use STP (Shielded Twisted Pair) cable to prevent electromagnetic interference.
3
Connect the PA-300 AC adaptor to the adaptor box.
4
Plug the AC adaptor into an appropriate AC mains outlet.
6
ICP1 Owner's Manual
1
Control panel unit
ICP 1 ADA
PTO R BOX
ICP 1
DC IN
MAD E IN
JAP AN
3
ICP1 adaptor box
D C IN
Cord hook.
AC adaptor (PA-300)
To AC power outlet
4
Control panel unit
Earth screw.

Advertisement