(English version)
Main Features of the Meter
• Both forward (Positive) and reverse (Negative)
current flows can be measured.
• The "CHARGING" LED on the right lights when
the battery is charging.
• Other LEDs (V, TIME, W, A, AH, %) show what
the display to the left is measuring.
• The measured values are shown on two-line
seven-segment multi-function displays:
On the top line is a four-digit display, toggled by
the V/W button between
- Voltage (V), Power (W) and Working Hours (H)
On the bottom line is a three-digit display,
toggled by the A/AH button between
- Current (A), Ampere-hours (AH) and
Remaining Capacity Percentage (%).
• There is a flexible calibration process for voltage,
current and Amp-hours/ % capacity
• The meter does not require external power when
measuring between 10V and 90V.
• The meter consumes very little power for its own
operation.
Specification
• Power supply required: DC 10 to 90V (external
or internal)
• Measuring range:
(1) Using an external power supply - Voltage 0
to 120.0V / Amp 0 to 30.0A
(2) Using an internal power supply - Voltage 10
to 90.0V / Amp 0 to 30.0A (Figures 1)
• Accuracy: Volts ± 1% + 2byte, Amps ± 2% +
5byte
• Resolution 0.01V, 0.01A, 0.01W, 0.01Ah
• Dimensions: 79mm x 43mm x 30mm
• Panel cutout: 76.5mm x 39.2mm
• Sampling rate: 5 reading per second
• Displays: 4 and 3 digits Red LED
• Operating Temperature: 0 to 50°C
• Operating Humidity: 35 to 85% Relative
Humidity
• Weight: 70g
- 1 -

Advertisement

loading
Need help?

Need help?

Do you have a question about the DCM-12030C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elite DCM-12030C

  • Page 1 Instruction Manual for Multi-function Panel Meter Model – Elite DCM-12030C (English version) Main Features of the Meter Specification • Both forward (Positive) and reverse (Negative) • Power supply required: DC 10 to 90V (external current flows can be measured. or internal) •...
  • Page 2 2. Power the Elite panel meter by external source. • By default, when the meter is first powered up, 3. Using the SET button on the Elite panel meter, the display on the top line shows voltage (V) and select the first item of the debug menu.
  • Page 3 Such resets are necessary for the initial installation of either the meter or a battery, so that the Elite meter 1. This resets values for debug menu items V, A correctly display the actual remaining capacity of the and AH to factory default values.
  • Page 4 4. Press the V/W button to select “-y-” (Yes), or Figures 1 press the A/AH button to select “-n-” (No). 5. Save the settings by pressing the SET button to confirm the -y- or –n- selection. Setting the Value for Remaining Amp-hour and Remaining Capacity % Such resets are necessary for the initial installation of either the meter or a battery, so that the display...