Page 1
IS185 Rev.05 06/04/2023 AUTOMAZIONE PER BARRIERE STRADALI Barriera automatica Brushless serie BIONIK Automatic barrier Brushless BIONIK series Automatisierung für Schranke Brushless Serie BIONIK Barrière automatique Brushless série BIONIK Barrera automática Brushless serie BIONIK Barreira automática Brushless série BIONIK Szlaban automatyczny Brushless seria BIONIK ISTRUZIONI E AVVERTENZE PER L’INSTALLATORE...
GENERAL SAFETY PRECAUTIONS Failure to respect the information given in this manual may cause personal injury or damage to the device. SYMBOLS Generic danger Useful information Refer to the Installation and use instructions DECLARATION OF CONFORMITY Roger Technology - Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV) •...
TECHNICAL CHARACTERISTICS BI/004HP BI/004HP/115 BI/006 BI/006/115 SERIE BIONIK BI/001PE BI/004HP/IS BI/004HP/IS/115 BI/006/IS BI/006/IS/115 POWER SUPPLY MOTOR POWER SUPPLY STARTING POWER 450 W 220 W 220 W 220 W 220 W POWER CONSUMPTION TORQUE OPEN / CLOSE TIME ABSOLUTE ENCODER ABSOLUTE ENCODER ABSOLUTE ENCODER ABSOLUTE ENCODER ABSOLUTE ENCODER...
Page 5
REFERENCES AND ACCESSORIES 17 19 Code Description Code Description SP/85/01 KT231 BAFS/01 BAFS/03 BAFS/02 BAFS/04 BAFS/05 BAMS/01 CTRL/P BI/001/PE CTRL BAMS/01/EXT BARK/02 SND/BA/91/DW SND/BA/91/UP KT242 JNT/BA/91 KT230 BI/BAT/KIT BA/91/3 BI/BCHP BA/91/4 KT239 R99/BASB20 BA/91/6 RS/GR1/100 ALED/4C ALED/6C CRA/BAR SP/72/01 CRA/BAR/M90 SP/83/01 ATTENTION! For the correct installation and use of the accessories refer to the respective instruction manuals.
Page 8
12.4 Selecting direction of aperture side (seen from the inspection hatch side). INSTALLATION Whenever corrective actions are carried out, pay the utmost attention when ON THE LEFT releasing, locking or moving the internal mechanical parts. These opera- tions could be hazardous for the installer. •...
Page 10
INSTALLING AND ADJUSTING THE SPRING NOTE SP/72/01 SP/83/01 SP/85/01 IMPORTANT: Using the holes furthest from the centre of the linkage lever (A-1) will result in a higher spring tension when the barrier is operating. Using the holes closest to the centre of the linkage lever (C-3) will result in a lower spring tension (see paragraph 12.2). RS/GR1/100.
Page 11
13.2 Spring tensioning BARRIER INSTALLED ON THE RIGHT - MAGGIORE TENSIONE MEDIA TENSIONE MINORE TENSIONE HIGHER TENSION MEDIUM TENSION LOWER TENSION BARRIER INSTALLED ON THE LEFT - MAGGIORE TENSIONE MEDIA TENSIONE MINORE TENSIONE HIGHER TENSION MEDIUM TENSION LOWER TENSION APPROXIMATE EXAMPLES Each installation is unique and the tension of the springs must be checked and tested.
Page 12
13.3 Spring selection rubber and LED strips. BI/001PE BI/004HP BI/006 integrated magnet BAFS/05 must be used. integrated magnet BAFS/05 must be used. integrated magnet BAFS/05 must be used. integrated magnet BAFS/05 must be used. WARNING! Images are purely indicative, for correct installation and use of the accessories refer to the respective instruction manuals.
Need help?
Do you have a question about the BIONIK Series and is the answer not in the manual?
Questions and answers