  • Page 1 Home Energy Storage System User manual...
  • Page 3 WY51100 1. Instructions for Use Please read all instructions in the manual carefully before installation and use. 1.1 Usage Guidelines This product should be used in accordance with local standards, laws and regulations, and any behavior that does not meet the requirements of use may cause personal injuryInjuries and property damage.
  • Page 4 WY51100 2. Safety Precautions 2.1 Security Symbols This device contains the following symbols, please pay attention to identify. symbol Description Comply with the attached documents Danger There's a risk of electrocution! High pressure is dangerous High pressure in energy storage systems can be life-threatening...
  • Page 5 WY51100 In the event of a fire, evacuate the building or equipment area and press the fire alarm bell or call the fire department.In any case, it is strictly prohibited to Enter the fire building. In any case, the structure and installation sequence of the equipment shall not be changed without the permission of the manufacturer.
  • Page 6 WY51100 Do not use water or detergent to clean the internal and external electrical components of the cabinet. Do not stand, lean or sit on the device. Do not damage any parts of this device. 2.3 Personnel Requirements The personnel responsible for installation and maintenance must be strictly trained to understand all safety precautions and master the correct method of operation.
  • Page 7 At the same time, it adopts modular structure design. Each energy storage module with the intelligent BMS system is internally integrated and easily expandable. WY51100 can match inverters of major brands, such as SMA, Victron, Growatt, GoodWe, Deye, Jinlang, SRNE etc.
  • Page 8 WY51100 3.2 Description of Energy Storage Capacity The energy storage system supports capacity expansion of up to 3 energy storage modules. Combining up to 15kWh battery packs. 5 KWH 10 KWH 3.3 Description of Appearance 3.3.1 Product Dimensions battery battery...
  • Page 9 WY51100 3.3.2 Storage Battery Module Switch Negative terminal Positive terminal Wall pulls LED (SOC) CAN / RS485(Intercom interface) RS485(External communication RESET interface) Communication interface definition Communication Feature Interface type Picture Instructions 1-RS485-B Connected 2-RS485-A RS485-1 RJ45 7-RS485-A inverter 8-RS485-B Connected...
  • Page 10 WY51100 4. Application Scenarios The energy storage module uses lithium iron phosphate battery with excellent performance and long life. At the same time, modular structure design is adopted. Each energy storage module and the smart BMS system is integrated internally and can be easily scaled up to a 15kWh battery pack.
  • Page 11 WY51100 At night, the battery supplies power to the load through the power module. 4.1.3 Complete Application Scenarios During the day, the power supply and PV simultaneously charge the battery and supply power to the load.
  • Page 12 WY51100 At night, the power supply supplies power to the load and continues to charge the battery if it is not fully charged. If the power supply is disconnected, the battery supplies power to the load. 5. Product Installation 5.1 Check Before Installation...
  • Page 13 WY51100 5.1.1 Installing Components Before the installation, check whether the components are complete according to the table. Quantity Picture Unit Specification Source 580×145×12 Top cover Carton (mm) 5.12kWh / Battery Battery pack 51.2V 580×145×60 Base Carton (mm) 200×68×20 Mounting rack...
  • Page 14 WY51100 5.2 Installation Position 5.2.1 Basic Requirements Before the installation, check whether the components are complete according to the table. Do not install in the storage area of flammable and explosive materials. If the accumulator is installed in a salt-affected area, corrosion and fire may occur.
  • Page 15 WY51100 5.3 Device Installation 5.3.1 Selecting an Installation Location To determine the installation location, select a flat floor and solid wall as the installation location. Determine the installation position of the base. Second, determine where the battery is installed. 5.3.2 Installation Process First place the base on a flat ground, place the battery on the base, and then tighten the fixing screws on both sides.
  • Page 16 WY51100 6. Electrical Connection Before electrical connection, ensure that the energy storage switch is in the "Off" state. Otherwise, the high voltage of the device may lead to electric shock. Operations related to electrical connections must be performed by professional electrical technicians. When making an electrical connection, Operators must wear personal protective equipment.
  • Page 17 WY51100 The power cord and signal cable delivered With the product are connected to the corresponding interface of the battery module as shown in the diagram. Power cord 6.2.2 Setting the Storage Battery Module Address If multiple energy storage battery modules are used in parallel, the modules automatically...
  • Page 18 WY51100 7 Mounting the Cover When all wiring is complete and the system is functioning properly, close the side cover.
  • Page 19 WY51100 8. System Maintenance 8.1 System Power off After the system is powered off, there is still residual power and heat in the enclosure, which may cause electric shock or burns. Therefore, in the system To operate the accumulator 5 minutes after the power is off, protective gloves should be worn.
  • Page 20 WY51100 8.3 Storage and Maintenance of Batteries 8.3.1 Battery Storage Requirements Do not put the battery in the fire. The battery may explode. Do not open or damage the battery. The electrolyte flowing from the battery is harmful to the skin and eyes. Electrolytes can also be toxic;...
  • Page 21 WY51100 8.3.2 Battery Charging Requirements Batteries stored for a long time (unused, more than 3 months) must be stored in a dry and cool place. The storage voltage is 51 V-53 V. The battery should be stored in a clean environment of 23±2 °C, and the humidity is 45%~75%.
  • Page 22 WY51100 9. Technical Data Battery type LiFePO4 Battery energy 5.12 kWh Battery capacity 100 Ah Battery voltage rating 51.2 V Battery operating voltage range 44.8~57.6 V Maximum charging current 100 A Maximum discharge current 100 A Depth of discharge Tied quantities...
  • Page 23 WY51100 10. Product Size and Packaging 10.1 Product Size The top cover dimensions are 580×145×12 mm, the energy storage battery module is 580×145×480 mm, and the base module is 580×145×60 mm. 10.2 Package Size The conventional packaging method for a single energy storage battery module is a...
  • Page 24 www.wanroytech.com info@wanroytech.com...