ALTIS G5 Installation instructions Asennusohje Instalacijas instrukcija Montageanleitung Notice de montage Monteringsanvisning Montážní návod Szerelési útmutató Instrukcja montazu Monteringsvejledning Istruzioni di montaggio Installationsanvisning Paigaldusjuhend Montavimo Instrukcijos TYPE : ALG5 - 288L - 336L IP66 / IK08 =23.7 kg The luminaire with clear optic should be...
Page 2
DIMENSIONS ALG5 288L 336 L 100 60 S c X0° S c X15° S c X45° S c X65° S c X90° ALG5 2 BRICKS 0.152 0.181 0.294 0.347 0.366 These data refer to the worst case at indicated angle ALG5 GB LE ALG5 GB 2CH 96681046-05...
Page 3
For installation higher >3m Secure product with retaining cable attached to the frame (not included in the delivery). Please refer to local installation norms/regulations. 2 2xM20 with extra large washer (not provided) 1xM20 with extra large washer (not provided) 25 Nm 3.5 Nm 96681046-05 11/2023...
CONNECTION BOX Choose the right position for the connection box Version G4/G5 Retaining washer 90° 70° 70° max Cable glands Cable glands 96681046-05 11/2023...
ELECTRICAL CONNECTION ALG5 GB LE 432L Output side ALG5 GB 2CH Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire 5 1234 Ø...
ALG5 GB 2CH / ELECTRICAL CONNECTION / DALI 2 Channels Mains (IN) Signal LED Floodlight Output (OUT) Ventilation valve DALI Re-launch (IN/OUT) DALI (IN/OUT) 5 1234 19/30/36 Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire PINOUT Number...
Page 9
ALG5 GB 2 CH / ELECTRICAL CONNECTION / RDM-DMX 2 Channels Mains (IN) Signal LED Floodlight Output (OUT) Ventilation valve Ø min = 1,0 mm² DALI Re-launch (IN/OUT) Ø typ = 1,5 mm² Ø max = 2,5 mm² DALI (IN/OUT) 5 1234 19/30/36 Extreme caution : Do not connect any LED CONNECTION wire...
Page 10
Mains (IN) Output (OUT) Floodlight (IN/OUT) (IN/OUT) Mains (IN) 200/400V recommended- 200 M Max : 30 GB per line – 20 « DMX-RDM wiring shall respect ANSI E1.11 and AINSI E1.20 installation rules». 1 to 3 DMX addresses per GB – changeable via RDM Last device on the line shall be properly terminated with a 120R 0.5W 5% resistance (96683550) DMX OUT...
Page 12
ALG5 GB 2CH / 200-250 Vac - ALG5 GB 2 CH /250-440 Vac CIRCUIT BREAKER recommendation It should mentioned in the notice that calculation has been done with a Circuit Breaker Load Factor of 100%. Inrush Current Data # Drivers for each Circuit Breaker V in I peak Half Value...
Page 13
ALG5 GB LE 432L / ELECTRICAL CONNECTION 8-9 mm INPUT OUTPUT Floodlight Ø min = 1,0 mm² Ø typ = 1,5 mm² Ø max = 2,5 mm² Ventilation Valve 12 34 PINOUT L N PE PE NC DA+ DA- V3+ V3- V2+ V2- V1+ V1- Number Label Description...