4. HEATER LOCATION
Your Sealey heater will generate radiated heat to a maximum area of approximately 25mtr
important to locate your heater correctly in order to achieve maximum benefit whilst avoiding any potential hazards.
The heater should only be used outdoors or in very large well ventilated areas.
The following location instructions must also be observed:
4.1.
Ensure the surface on which the heater is to stand is level, smooth and flat. Avoid any surface that may cause the heater to topple.
4.2.
Ensure the heater is located at a minimum of 1mtr from fixed objects such as wall, ceiling, doors, panelling etc. and not in the same
building as flammable liquids, solids or gases.
4.3.
Ensure that there is no possibility of the heater being blown over by strong winds.
4.4.
Other features that will assist to enhance the comfort of the heated environment and reduce gas consumption:
a) Placing heater under sun or rain awning when used outside.
b) Protecting the heated area from draughts and winds.
4.5.
Ensure the location of the gas heater does not contravene Health and Safety, fire, or any other local rules, legislation or regulations.
Fig. 10
5. OPERATING INSTRUCTIONS
Note: Ensure you have read and understood the safety instructions in Section 1.
When you first light the heater, the unit will give of a light smoke. This is caused by the burning of protective lubricant and will cease
after a short time. You may also experience a slightly irregular flame at first which will gradually settle once all the air has been
eliminated from the gas piping. It is also normal to experience a short term irregular flame, caused by air in the system, each time a gas bottle
is changed.
5.1.
To turn ON
5.1.1. Check heater for possible gas leaks by opening the gas bottle valve and then brushing a soap solution over each connection in
the system. If bubbles develop in the solution this indicates a leak which must be corrected before the unit is ignited. Immediately
turn the control tap off and re-make any suspect joint. Re-check for leaks.
WARNING! DO NOT use a flame to test for leaks.
Important! If it becomes necessary to replace the hose, the length of the new hose must not exceed 1.1mtr.
5.1.2. When you are sure there are no leaks and with the gas bottle valve open proceed as follows:
5.1.3. Turn the temperature control knob (fig. 10.A) to the ‘MIN’ position and depress (fig. 10.B), at the same time press the ignition button
(fig. 10.C). It may be necessary to press the ignition button several times to light the pilot flame.
5.1.4. Once the pilot light is lit hold the temperature control knob (fig. 10.A) fully in for a further 10 - 15 seconds and then release.
5.1.5. Check that the pilot flame remains alight.
5.1.6. If the flame goes out, turn the temperature control knob off and turn off the gas bottle, leave the heater to stand for one minute and
then repeat steps 5.1.3 to 5.1.5
5.1.7. Turn the temperature knob to the desired heat setting.
5.2.
To turn OFF
5.2.1. To turn the heater off, turn the control knob (fig. 10.A) to the ‘ ‘ (off position), check that the flame is extinguished and turn off the
gas cylinder at the gas valve.
5.3.
Storage
When not in use store the heater in a safe, dry, childproof area. If being stored for long periods, i.e. during the summer, ensure
the gas bottle is removed and stored according to appropriate regulations. Remove the aluminium reflector from the heater and store
separately to avoid the risk of damaging or dulling the surface. Cover the remainder of the heater unit.
Declaration of Conformity
INFRARED PROPANE SPACE HEATER
Model LP352.V2 & LP352S
Gas Appliances (Safety) Regulations 1992
(S.I. 1992/711)
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No responsibility is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be
required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
We, the sole importer into the UK, declare that the products listed here are in conformity with the following standards and directives.
The construction file for these products are held by the Manufacturer and may be inspected, by a national authority,
upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
(depending on conditions). It is therefore very
2
Date 20th February 2004
01284 757500
Web address: www.sealey.co.uk
E-mail: sales@sealey.co.uk
01284 703534
LP352.V2, LP352S - 2 - 07/12/05
For Jack Sealey Ltd.
Sole importer into the UK
of Sealey Power Products.

Advertisement

loading

This manual is also suitable for:

Lp352s