Advertisement

Quick Links

VF1100 EP
User Manual
Caution: Fog machines may set off smoke alarms!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VF1100 EP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eliminator Lighting VF1100 EP

  • Page 1 VF1100 EP User Manual Caution: Fog machines may set off smoke alarms!
  • Page 2 All non-Eliminator brands and product names are trademarks or registered trademarks of their respective companies. Eliminator Lighting and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic...
  • Page 3: Table Of Contents

    C O N T E N T S General Information Limited Warranty (USA Only) Warranty Registration | Features Safety Guidelines Overview Installation Guidelines Remote Operation Fuse Replacement | Storage and Maintenance | Trouble Shooting 15 Dimensional Drawings Specifications...
  • Page 4: General Information

    Congratulations on your purchase of one of the most reliable fog machines on the market today! The VF1100 EP commercial fog machine has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit.
  • Page 5: Limited Warranty (Usa Only)

    ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the Eliminator Lighting factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Eliminator Lighting will pay return shipping charges only to a designated point within the United States.
  • Page 6: Warranty Registration | Features

    WA R R A N T Y R E G I S T R AT I O N This device carries a one year (365 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
  • Page 7: Safety Guidelines

    S A F E T Y G U I D E L I N E S • In the event that the device needs to be return to Eliminator Lighting for service, use only the original packaging and materials for shipping.
  • Page 8: Overview

    O V E R V I E W Heating Ready Fluid Indicator Indicator Reservoir Mounting Bracket Controller Port Button Bracket Adjustment Bracket Knob Adjustment Knob Fluid Power Fuse Level 10A (120V) Window 5A (230V)
  • Page 9: Installation Guidelines

    I N S TA L L AT I O N G U I D E L I N E S ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO! Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
  • Page 10 I N S TA L L AT I O N G U I D E L I N E S CLAMP MOUNTING To install this device in a suspended environment, insert a bolt of the proper weight rating through the bottom of an appropriately rated mounting clamp as well as the mounting surface of the mounting bracket, then fasten in place with a bolt of the appropriate rating.
  • Page 11 I N S TA L L AT I O N G U I D E L I N E S RIGGING Overhead rigging requires extensive experience, including but not limited to: calculating working load limits, understanding the installation material being used, and periodic safety inspection of all installation material and the fixture itself.
  • Page 12: Remote Operation

    R E M O T E O P E R AT I O N Always be sure to maintain an adequate supply of fog juice in the fluid reservoir. Running the fog machine dry will result in pump failure and/or clogging, and is the most common cause of failure in fog and haze machines.
  • Page 13 R E M O T E O P E R AT I O N VFEP5R WIRED REMOTE Connect the VFEP5R remote to the controller port on the fog machine. Plug the fog machine in and turn it on, and allow the unit to warm up for approximately 2 minutes. After the unit has reached oper- ating temperature, the green LED on the remote will illuminate, indicating that the unit is ready to emit fog.
  • Page 14 R E M O T E O P E R AT I O N VFEPWR WIRELESS REMOTE The VF1100 comes with an internal wireless receiver and wireless remote (VFEPWR). To use the wireless remote, press button 1 on the remote when the fogger is ready to emit fog. WIRELESS INSTALLATION GUIDELINES For best results, position the fixture so that the display screen is oriented in the direction of the transmitter device or remote.
  • Page 15: Fuse Replacement | Storage And Maintenance | Trouble Shooting

    F U S E R E P L A C E M E N T Disconnect the unit from its power source. Remove the power cord from the unit, then find the fuse holder located inside the power socket. Insert a flat-head screw driver into the power socket and gently pry out the fuse holder.
  • Page 16: Dimensional Drawings

    D I M E N S I O N A L D R AW I N G S 7.7in (196.6mm) 10.3in (261mm) 13.3in (339mm) 13.4in (341mm)
  • Page 17: Specifications

    S P E C I F I C AT I O N S • High efficiency heater block burns through fog with less residue • Electronic Thermo Sensing (ETS) for optimum heating levels • Low fog fluid shut off sensor to protect pump •...