Defrosting; Connecting The Water Hose; Removing And Emptying The Water Tank; Cleaning And Storage - ProBreeze PB-06 Instruction Manual

12l compressor dehumidifier
Hide thumbs Also See for PB-06:
Table of Contents

Advertisement

Setting a Turn-Off timer:
1.
Press the Power button to turn the dehumidifier on.
2.
Set the dehumidifier to the desired settings.
3.
Press the Timer button to activate the timer function.
4.
Press Timer button to set the desired time (1-24 hours).
5.
The time digits will blink five times to confirm a timer has been set and then revert to the
current room humidity.
6.
To check the remaining time until Time-Off press the Timer button.
SLEEP Mode: Press the SLEEP mode / STORAGE Cycle Button to activate. In SLEEP mode the
dehumidifiers humidity is set to 50% and the fan operates in low speed. If the actual room
humidity is 5% greater than 50% humidity the dehumidifiers compressor will activate, and the
fan will operate at low speed. If the actual room humidity is 5% less than 50% humidity the
dehumidifiers compressor will stop collecting water but the fan will continue to operate at low
speed.
Note: Fan speed cannot be adjusted when SLEEP mode is set.
STORAGE Cycle: Press and hold the SLEEP mode / STORAGE Cycle button for three seconds to
activate. The dehumidifiers compressor stops collecting water, and the fan runs at high speed
for 30 minutes followed by a further 20 minutes at low speed. This process dries the dehumidifier
prior to storage.
Note: Prior to storage ALWAYS run a STORAGE cycle.
Fan Speed Button: Sets the fan speed to HIGH or LOW speed.
Humidity Button: Sets your desired humidity level between 80% - 30% humidity in 5%
decrements.
Mode / Child Lock Button: Select between AUTO mode / CONTINUOUS mode / Child Lock.
AUTO Mode: In AUTO mode if the actual room humidity is 5% greater than that of the set humidity
the dehumidifiers compressor will activate, and the fan will operate at the set fan speed. If the
actual room humidity is 5% less than that of the set humidity the dehumidifiers compressor will
stop collecting water, but the fan will continue to operate at the set fan speed.
CONTINUOUS Mode: In CONTINUOUS mode the dehumidifiers compressor and fan (at the set fan
speed) will continuously operate. In this mode the fan speed is adjustable.
Child Lock: Locks the controls for child safety. Press and hold the Child Lock button for three
seconds to lock and unlock. The display panel will show LC for five seconds after Child Lock is
activated prior to returning to the current room humidity.
Power Button: Turns the dehumidifier ON and OFF.
10 of 14 | English

DEFROSTING

― ―
The unit may need defrosting in temperatures less than 16°C. This will happen automatically and
last up to ten minutes. During this time, P1 will show on the display panel and the compressor will
stop collecting water but the fan will continue to run at its prior setting.
Do not switch off while the unit is defrosting.
CONNECTING THE WATER HOSE FOR CONTINUOUS DRAINING
― ―
For long-term use, it is recommended to connect a hose
for continuous drainage. To attach the hose:
1.
Remove the plug from the water hose connector
located on the back of the dehumidifier.
2.
Insert the hose into the water hose connector and
check it is connected properly.
3.
Ensure the hose end has a suitable drainage outlet
(e.g. a drain or bucket).

REMOVING AND EMPTYING THE WATER TANK

― ―
When the water tank is full 10 beeps will sound; the Water
Tank Full indicator light will illuminate, and the dehumidifier
will pause operation to prevent the water tank from
overflowing. To remove and empty the water tank:
1.
Turn off the dehumidifier and unplug it from the wall
socket.
2.
Gently pull the water tank out from the front of the
dehumidifier.
3.
Empty the water tank.
4.
Once empty, slot the tank back in carefully.

CLEANING AND STORAGE

― ―
WARNING: ALWAYS TURN THE APPLIANCE OFF AND UNPLUG
THE POWER CORD FROM THE ELECTRICAL OUTLET BEFORE
HANDLING OR CLEANING IT.
English | 11 of 14

Advertisement

Table of Contents
loading

Table of Contents