Stove Installation And Connection; Chimney Connection - Teba therm TS-13 Installation Manual

Table of Contents

Advertisement

Minimum distances for flammable materials and furniture are indicated on the
product label and must not be exceeded. If the floor where the stove needs to be
installed is flammable or heat-sensitive, you should place the product on the
ground protection plate (eg marble or glass base).
In this case the minimum dimensions of stove bottom plate (look at drawing)
should be:
D
50cm (front length)
E
30cm (lateral length from the inner edge of the fire chamber cover)
You can order the floor protection plate from seller when you require.

4.2 STOVE INSTALLATION AND CONNECTION

Product installation and assembly should be done according to the user manual
and by an authorized person. Since our wood stove for a flat is designed for
interior and provide heat to the ambient, it should not be installed in bathroom,
balcony, cellar, woodshed, etc... The distance between stove and chimney must be
close.

4.2.2 Chimney Connection

For stove connection steel sheet flue pipes of 2mm thickness must be used. Stove
pipe must be connected to stove chimney output and chimney firmly. This strong
and close connection is also compulsory for flue pipes. After connecting flue pipe to
the chimney, remaining gaps around chimney must be closed with sealing and
fireproof materials. When the distance between stove and chimney is long,
horizontal connection must be avoided. Chimney pipe must be installed according
to the direction of the chimney. When the distance is short at least 1meter length
flue pipe must be used and must be installed vertically.
The chimney to be used at the exhaust gas outlet can be multiple chimney
connection (See Chimney Assembly Diagram)
CAUTION: Do not burn the stove when the flue pipe is connected. First of all,
the radiator installation must be done ( Otherwise stove burned without
water can lead to stove deformations). Our company is not responsible for
damages caused by burning without water.
The chimney connection should be done according to DIN4705.