UNPACKING THE UNIT
Each unit is shipped with the 5" lamp installed and the germicidal lamps
placed in boxes with protective packaging. Carefully remove lamp from
the tube taking care to not touch the glass portion of the lamp with bare
hands. Oils from the hands can cause "hot spots" which reduce lamp life.
Handle by the end caps or use a soft cloth. If you accidentally touch
a lamp, clean it using the included alcohol cleaning pad or a soft cloth
dampened with rubbing alcohol. The lamp is fragile and proper care
must be taken when removing from packaging.
The following parts are included:
• MUV-403H-R Unit
• (2) Two germicidal twin lamps
(packed in lamp box)
• (8) Eight sheet metal screws
IMPORTANT: SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. SAVE THESE INSTRUCTIONS.
3. Always be sure power is disconnected during installation or service procedures.
4.
The ultraviolet light produced by the UV lamp is harmful to your eyes. Do not look directly at
the lamp. Should it become necessary to view the lamp, use UV-protected goggles.
Lors de l'installation et de l'utilisation de cet équipement, des précautions devront être suivies.
1- Lire et suivre les étapes attentivement.
2- Conserver ces instructions.
3- Assurez-vous toujours que l'alimentation est débranchée pendant les procédures d'installation
ou de maintenance.
4-
Ne pas regarder la lampe directement avec les yeux. Si nécessaire de le faire, veuillez porter
veuillez porter les lunettes de soleil contre les rayons U.V.
Important: Instructions de securité
should always be followed including the following:
3099107
• Alcohol pad for cleaning lamps
• Strain relief connector
• Two caution labels
• Installation & maintenance instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUV-403H-R and is the answer not in the manual?

Questions and answers

Summary of Contents for Premier MUV-403H-R

  • Page 1 The lamp is fragile and proper care must be taken when removing from packaging. 3099107 The following parts are included: • MUV-403H-R Unit • Alcohol pad for cleaning lamps • (2) Two germicidal twin lamps • Strain relief connector (packed in lamp box) •...
  • Page 2: Installation

    INSTALLATION: If there is a device that creates ozone in the space such as an ionizing air cleaner, it is recommended the oxidizing unit not be used in this application. Use one of our germicidal only models instead. Homes with multiple air handlers: install this unit on the main level air handler and a germicidal only model on the other air handler(s).
  • Page 3: Wiring Option

    WIRING OPTION 1 This unit must cycle with the furnace blower. The multivoltage ballasts are self-adjusting and operate with voltages from 120 - 240 VAC. IWire the unit to an EAC terminal or current-sensing relay to cycle the unit with the system fan. Connect in accordance with local wiring codes.
  • Page 4: Maintenance

    Secure cover using the two retaining nuts. 12. Restore power to unit. AIR STREAM MUV-403H-R Shown installed on a furnace. Mount the MUV-403H-R on the air return and the second UVC lamp on the supply side.
  • Page 5 Photo A Oxidation lamp connector Remote germicidal lamp connector Photo B Photo C LSK100TR-16/5 LAMP KITS FOR MUV-403H-R #LSK100TR-16/5 60-Watt UVC/UVV lamp service kit with 16” UV lamp. #LSK100TR-12/5 80-Watt UVC/UVV lamp service kit with 12” UV lamp.
  • Page 6: Troubleshooting

    MAINTENANCE AT TWO YEARS This maintenance schedule is only a guideline, determined by average conditions. Actual conditions will dictate the frequency of cleaning and/or replacement of lamps. Do not touch the glass portion of the lamps with bare hands because oils from the hands can cause “hot spots” which reduce lamp life. Handle either by the end caps or use a soft cloth.
  • Page 7 INSTALLA Lamp 4” Use a 2” hole Mounting the main unit on return air duct. 1. Cut out area of template indicated by the two circles if using a hole saw. 2. Place template on the return path of the HVAC system and trace the hole pattern for the unit and mark cen Unit must be oriented so long dimension is parallel to the direction of the air flow parallel to the direction 3.
  • Page 8 10 3/4” ATION TEMPLATE MUV-403H-R Oxidation Chamber saw to cut 2 openings indicated by the gray circles. nters for mounting screws. of the air flow. ng sheet metal screws provided. REMOTE LAMP TEMPLATE n snips.
  • Page 9 Products, Inc. (“PremierOne”) warrants MUV-403H-R-16/5 consequential damages or limitation of the duration of an implied MUV-403H-R-12/5 (the “Product”) to be free from de- warranty, so the above limitations or exclusions may not apply to fects in manufacturing, materials, and workmanship for the life the customer.

Table of Contents