Table of Contents

Advertisement

Quick Links

Installer: Leave this manual with the appliance. - Owner: Retain this manual for future reference
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance
WHAT TO DO IF YOU SMELL GAS.
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any phone in
your building
• Leave the building immediately
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you can not reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
INSTALLATION MANUAL
Gas Fireplace
EKKO G U 60/14-19, EKKO G L 60/14-19, EKKO G R 60/14-19, LINA G 60-19
DANGER
Hot glass will cause burns
Do not touch glass until cooled
Never allow children to touch glass
• A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and must be
installed for the protection of children and other at-risk
individuals.

Advertisement

Table of Contents
loading

Summary of Contents for Camina & Schmid EKKO G U 60/14-19

  • Page 1 • If you can not reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. INSTALLATION MANUAL Gas Fireplace EKKO G U 60/14-19, EKKO G L 60/14-19, EKKO G R 60/14-19, LINA G 60-19...
  • Page 2: Table Of Contents

    Table of Contents Introduction About this manual Safety Marks General Safety Information Product Information Appliance Certification Product Specifications High Altitude Installations. Installation of Carbon Monoxide Detectors Signage Exemptions Fireplace Safety Appliance Safety Glass Venting Intended Use Installing and Servicing Installation Prior to Starting the Installation.
  • Page 3 Placing the Burner Logs and Media Arrangement Birch and Oak Log Kit Framing Framing Requirements Chase Floor/Platform. General clearances. 8.3.1 Viewing area clearing zone. Heat release. Calculating Convection Air Outlet Opening. Sprinkler Clearance to Heat Release Air Intake Opening Heat Transfer to Rooms other than the Room where the Fireplace is Installed. Recessed TV/Artwork.
  • Page 4 13.5.9 Countdown Timer 13.5.10 2nd Burner Function Appendix 6 - Dimensions 14.1 LINA G 60-19 14.2 EKKO G U 60/14-19 14.3 EKKO G L 60/14-19 14.4 EKKO G R 60/14-19 Appendix 7 - Access panel Appendix 8 - Maintenance 16.1 Firebox 16.1.1...
  • Page 5 Fig. 32: LINA G 60-19 - Dimensions - Top View Fig. 33: EKKO G U 60/14-19 - Dimensions - Front View Fig. 34: EKKO G U 60/14-19 - Dimensions - Left Side View Fig. 35: EKKO G U 60/14-19 - Dimensions - Right Side View Fig.
  • Page 6: Introduction

    Introduction Introduction About this manual These are the original assembly instructions in English. A French version is also available. Please check the website ( www.camina- ) for the latest version of the manual. schmid.com The gas fireplace inserts are built according to state-of-the-art technology and recognized safety regulations. These assembly instructions will help you to handle the heating technology "gas fireplace insert"...
  • Page 7: General Safety Information

    Introduction General Safety Information Local codes and regulations that are more stringent than the requirements in this manual take precedence over Camina & Schmid Inc. requirements. DANGER Fireplace Operation • Do not operate the fireplace: • If the glass is NOT properly secured in place. •...
  • Page 8 Introduction WARNING Material Usage • All materials and objects used to carry out the installation must be certified/approved or specified by Camina & Schmid Inc. and be suitable for use. Do NOT install the system with different materials or objects than those approved for installation as specified in this manual.
  • Page 9: Product Information

    CSA 2.17 2017, Gas-Fired Appliances for Use at High Altitudes • CSA P.4.1 – 2021 - Testing Method for Measuring Fireplace Efficiency. Table 1: Product Specifications Unit Natural gas EKKO G U 60/14-19 Model EKKO G R 60/14-19, EKKO G L 60/14-19 LINA G 60-19 Natural Propane...
  • Page 10: Product Specifications

    Product Information Product Specifications High Altitude Installations. Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet [ 1,370 m ] above sea level. REGULATIONS Elevations • For elevations above 2,000 feet [ 610 m ] in USA - Installations must be in accordance with the current ANSI Z223.1 and/or local codes having jurisdiction.
  • Page 11: Fireplace Safety

    Fireplace Safety Fireplace Safety Appliance Safety This manual contains very important information about the safe installation and operation of the fireplace. Read and understand all instructions carefully before installing and operating the fireplace. Failure to follow these instructions may result in possible fire hazard and will void the warranty. Replacement manuals are available by contacting the Camina &...
  • Page 12: Glass

    Fireplace Safety Glass WARNING Glass front • The glass front assemblies must be in place and sealed before the unit can be placed into safe operation. • Do not strike or slam the glass front. • Do not operate this appliance with the glass front removed, cracked, or broken. •...
  • Page 13: Installation

    Installation Installation Prior to Starting the Installation. NOTICE Read all the instructions before starting the installation • Follow these instructions carefully during the installation to ensure maximum safety and benefit. Follow the steps below to ensure proper installation of the gas appliance. Prior to starting the installation, make sure you read and understand all WARNING information in this manual.
  • Page 14: Preparing To Install

    Installation Preparing to Install. 4.2.1 Fireplace Positioning • Once the fireplace has been set to the upright position, it can be moved to its final installation location. • Make sure the control unit is secure and not dragging on the floor during transport and positioning.
  • Page 15: Venting And Vent Termination

    Venting and Vent Termination Venting and Vent Termination Instructions REGULATIONS Local Codes • These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSl-2223.1) and/or Natural Gas and Propane Installation Code, CSA B149.1.
  • Page 16: Approved Venting Components

    Venting and Vent Termination Approved Venting Components Table 2: Approved Venting Components Venting parts Duravent Length 5 x 8 in. inches centimeters Galvanised 58DVA-06 Black 58DVA-06B Galvanised 58DVA-07 Black 58DVA-07B Galvanised 58DVA-09 Black 58DVA-09B Galvanised 58DVA-12 Black 58DVA-12B Galvanised 58DVA-18 Black 58DVA-18B Galvanised...
  • Page 17: Typical Co-Axial Venting Components

    Venting and Vent Termination Typical Co-axial Venting Components HORIZONTAL TERMINATION VERTICAL TERMINATION STORM COLLAR 2-PIECE WALL THIMBLE FLASHING PIPE LENGTH ATTIC INSULATION SHIELD 90° ELBOW ATTIC FIRESTOP ATTIC FIRESTOP PIPE LENGTH 90° ELBOW 90° ELBOW PIPE LENGTH Fig. 5: Typical Co-Axial Venting Components Ekko &...
  • Page 18: Clearances

    Venting and Vent Termination Clearances 5.5.1 Minimum Clearances to Vent Termination 5.5.2 Horizontal Vent Clearances A minimum clearance of 3 in. [ 7.5 cm ] to the top and 2 in. [ 5 cm ] to the sides and bottom of the vent pipe on all horizontal runs to combustibles is required.
  • Page 19: Table 4: Vent Terminal Locations - Minimum Distances Measured From The Center Of Vent

    Venting and Vent Termination Fig. 6: Minimum Clearances to Vent Termination Table 4: VENT TERMINAL LOCATIONS - MINIMUM DISTANCES MINIMUM CLEARANCE Measured from the center of vent Inches Centimeters Clearance above grade, veranda, porch, deck or balcony. Clearance to window or door that may be opened. Clearance to permanently closed window (recommended to prevent condensa- tion on window).
  • Page 20: Vertical Termination

    Venting and Vent Termination NOTICE Termination installation • If installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding. The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
  • Page 21: Vent Pipe Clearances

    Venting and Vent Termination • A firestop spacer must be installed in the floor or ceiling of every level. • Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.
  • Page 22: Allowable Vent Configurations

    Allowable Vent Configurations Allowable Vent Configurations Horizontal displacement of the flue system is possible when the flue pipe has a minimum of 3 feet [ 0.9 m ] of vertical rise. The restriction plate maximum horizontal displacement is 20 feet [ 6.10 m ] excluding the wall terminal.
  • Page 23: Removing Or Installing Restriction Plates

    Allowable Vent Configurations Removing or installing restriction plates 6.1.1 Removing or installing the glass panes. Place the suction cup lifters on the glass pane, making When the barrier is released from the clamping device, sure they are securely fastened. The cup lifters are stored it can be lifted up and turned outwards from the bottom on the top of the appliance for transport.
  • Page 24: Removing The Catalyst

    Allowable Vent Configurations NOTICE Glass installation • The glass of the combustion chamber is infrared reflective glass. It is provided with a special layer that must be on the outside of the combustion chamber. The Camina & Schmid Inc. logo serves as an indicator and must be visible at the bottom right after the windows have been installed.
  • Page 25: Prepare Appliance For Wiring

    Allowable Vent Configurations Prepare Appliance for Wiring CAUTION Electrical installation • All electrical installations must be performed by a qualified electrician and must be electrically wired and grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. WARNING Usage •...
  • Page 26 Allowable Vent Configurations After you have connected the fire to the gas mains, the supply pressure can be checked. To do this, you must first remove the service hatch. This hatch is located at the bottom left of the combustion chamber.
  • Page 27: Placing The Burner Logs And Media Arrangement

    Placing the Burner Logs and Media Arrangement Placing the Burner Logs and Media Arrangement Birch and Oak Log Kit • Material required: • 6 burner logs • Several non-burning deco logs • 1 bag of yellow glass (8 cup bag) •...
  • Page 28 Placing the Burner Logs and Media Arrangement Place log L2 on the combustion chamber floor at the left side of L1 as shown in the picture. The positioning aid helps you place the block at the correct angle. Place log L3 on the combustion chamber floor near the end of L1, and onto the side of burner 1.
  • Page 29 Placing the Burner Logs and Media Arrangement Place log L4 on the right end of L3 to rest on the combustion chamber floor as shown. Place log L5 on the primary tube and the right end bottom of L4 as shown. A positioning aid is provided on the combustion chamber floor of the fireplace.
  • Page 30 Placing the Burner Logs and Media Arrangement 11. Place the non-burning logs 1 -6 on the bottom as shown 12. Complete by deposing the ash over the fireplace bottom decoration. Ekko & Lina G 60 Gas Fireplace - Installation Manual - V1.0...
  • Page 31: Framing

    Framing Framing Framing Requirements Fireplace chase may be framed with either combustible (typically wood studs) or non-combustible framing (typically metal studs). The framing of the fireplace chase must be designed to carry the entire weight of the wall and finish material. Surrounding material must not transfer weight to the fireplace or be connected in any way to the fireplace.
  • Page 32: Heat Release

    Effective min. inlet surface Effective min. Outlet Surface with Cavity vent Lina G 60-19 160 in 240 in 0.10 m 0.15 m Ekko G U 60/14-19 160 in 240 in 0.10 m 0.15 m Ekko G L 60/14-19 160 in 240 in 0.10 m...
  • Page 33: Calculating Convection Air Outlet Opening

    Framing Calculating Convection Air Out- 2 in. [5 cm] let Opening. As the openings come in all kinds of shapes and dimensions, we recommend that the area of the opening always be multiplied by a factor of 1.5 → We need to calculate with 160 in 0.10 m ] x 1.5 which makes 240 in...
  • Page 34: Heat Transfer To Rooms Other Than The Room Where The Fireplace Is Installed

    Framing Fig. 16: Air Intake Opening When the appliance is directly built on the floor and no side inlet is being used, the minimum height of the appliance bottom to the floor has to be adjusted to a minimum of 2 ½ in. [ 6.5 cm ] to allow a reasonable flow of convection air.
  • Page 35 Framing Ekko & Lina G 60 Gas Fireplace - Installation Manual - V1.0...
  • Page 36 Framing Ekko & Lina G 60 Gas Fireplace - Installation Manual - V1.0...
  • Page 37 Framing DV Pro 5 in. x 8 in. In Fig. 18 you see the EKKO G U [130 mm x 200 mm] Ceiling restop built in a wooden frame of 2x3  in. Conv. air ducts 2x7.5  cm ] wooden slats. Note Ø...
  • Page 38 Framing 58 1/4 in. [1480 mm] 18 1/8 in. [460 mm] 17 1/2 in. [445 mm] 5/8 in. 16 in. [15 mm] [410 mm] 24 1/8 in. 5/8 in. [15 mm] [615 mm] 42 3/4 in. [1085 mm] [890 mm] 108 in.
  • Page 39 Framing Please note that candles, contamination in the fireplace cavity, plasticizers from paint and dust can be transported in the warm air stream. This can pollute ceilings and walls. When the speed of the air is as low as possible and the temperature as low as possible, you will have the least trouble with this.
  • Page 40 Framing It is not often done in the corner with a 3-sided model of this size, but it is possible, as shown in Fig. 24. It is important to leave some space for disassembling the glass panes on the sides. Furthermore, the walls adjacent to the sides of the fireplace will heat up due to the radiant heat.
  • Page 41: Appendix 1 - Lighting Instructions

    Appendix 1 - Lighting Instructions Appendix 1 - Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. A.
  • Page 42: Appendix 2 - Wall Switch

    Appendix 2 - Wall Switch Appendix 2 - Wall Switch A wall switch kit is available. It can be ordered separately as a kit Increase with a 10-foot cable. flame height • The wall switch can take over the following functions. →...
  • Page 43: Appendix 3 - Wiring Diagram

    Appendix 3 - Wiring diagram Appendix 3 - Wiring diagram MAN knob Main valve knob Combination Control Valve Latching solenoid Black Interruptor block GV-560 (Latching solenoid is Thermocouple shown shut o but leaving on the burner) Thermocouple 2 Receiver Reset Mains Adapter Vac Fig.
  • Page 44: Appendix 4 - Warranty

    Appendix 4 - Warranty Appendix 4 - Warranty Camina & Schmid Inc. Limited Lifetime Product Warranty If the initial consumer purchaser has a problem with this unit, please immediately contact your Camina & Schmid Inc. dealer or supplier. Under no circumstances should the purchaser or anyone other than a technically certified Camina & Schmid Inc. dealer or distributor attempt to service the unit in any way.
  • Page 45: Conditions And Limitations

    Appendix 4 - Warranty 12.4 Conditions and Limitations The warranty registration card must be completed by the initial consumer purchaser and returned to the Company within 90 days of the original installation of the product. Installation and annual maintenance must be performed by a Company authorized, licensed, and qualified distributor or dealer in accordance with the Company’s installation instructions.
  • Page 46: Appendix 5 - Operation

    Appendix 5 - Operation Appendix 5 - Operation 13.1 Symax handset Technical data: Ambient temperature range: ............32 °F to 131 °F [0 °C to 55 °C] Radio frequency: ......................918.0 MHz Power supply: ..........2 x 1.5 V “AAA” (quality alkaline recommended). NOTICE Wiring of Control and Receiver •...
  • Page 47: General Notes

    Appendix 5 - Operation 13.3 General notes Batteries – Handset Low battery indicator on Symax. 13.4 Function Activation / Deactivation Deactivate Functions: Install batteries. All icons are displayed and flashing. While the icons are flashing, press the relevant function button and hold for 10 sec. The function icon will flash until deactivation is complete.
  • Page 48: Description Of The Functions

    Appendix 5 - Operation 13.5 Description of the Functions 13.5.1 Setting the Temperature Unit To change between °C and °F, press buttons simultaneously. NOTE : Choosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock. 13.5.2 Setting the Time Press...
  • Page 49: Standby Mode (Pilot Flame)

    Appendix 5 - Operation 13.5.5 Standby Mode (Pilot Flame) NOTICE Gas Supply • If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TO TURN OFF GAS TO APPLIANCE” (see page 41). Handset Press and hold button to set appliance to pilot flame.
  • Page 50: Countdown Timer

    Appendix 5 - Operation 13.5.9 Countdown Timer ON/SETTING Press and hold button until is displayed, and Hour flashes. To modify hour, press button. button. Minutes flashes. To confirm, press To modify Minutes, press button. To confirm, press button or wait. Press button.
  • Page 51: Appendix 6 - Dimensions

    Appendix 6 - Dimensions Appendix 6 - Dimensions 14.1 LINA G 60-19 141 mm / 5 141 mm / 5 1431 mm / 56 in max. 75 mm / 3 in 1488 mm / 58 min. 63 mm / 2 1 / 2 in 1713 mm / 67 1803 mm / 71 in Fig.
  • Page 52 Appendix 6 - Dimensions 35 mm / 1 150 mm / 6 in   max. 75 mm / 3 in. 50 mm / 2 in min. 63 mm / 2 1 / 2 in 86 mm / 3 258 mm / 10 USA_LIN 465 mm / 18 513 mm / 20...
  • Page 53: Ekko G U

    465 mm / 18 USA_G_U 513 mm / 20 dimension 580 mm / 22 left sid Fig. 34: EKKO G U 60/14-19 - Dimensions - Left Side View scale BIS-016 Ekko & Lina G 60 Gas Fireplace - Installation Manual - V1.0...
  • Page 54 465 mm / 18 dime 513 mm / 20 580 mm / 22 Fig. 35: EKKO G U 60/14-19 - Dimensions - Right Side View 1803 mm / 71 in 856 mm / 33 856 mm / 33 200 mm / 8 in ...
  • Page 55: Ekko G L

    Appendix 6 - Dimensions 14.3 EKKO G L 60/14-19 35 mm / 1 45 mm / 1 71 mm / 2 141 mm / 5 1536 mm / 60 in max. 75 mm / 3 in 112 mm / 4 min.
  • Page 56 Appendix 6 - Dimensions 35 mm / 1 150 mm / 6 in   50 mm / 2 in 86 mm / 3 258 mm / 10 465 mm / 18 513 mm / 20 580 mm / 22 Fig.
  • Page 57: Ekko G R

    Appendix 6 - Dimensions 14.4 EKKO G R 60/14-19 45 mm / 1 35 mm / 1 141 mm / 5 71 mm / 2 1535 mm / 60 in max. 75 mm / 3 in 112 mm / 4 min.
  • Page 58 Appendix 6 - Dimensions 71 mm / 3 in 174 mm / 6 364 mm / 14 in 50 mm / 2 in 86 mm / 3 513 mm / 20 580 mm / 22 dime Fig. 43: EKKO G R 60/14-19 - Dimensions - Right Side View 1803 mm / 71 in 856 mm / 33 856 mm / 33...
  • Page 59: Appendix 7 - Access Panel

    Appendix 7 - Access panel Appendix 7 - Access panel An access panel, or some other form of clear access to the chase, is not required, but it is highly recommended. It allows for access to the fireplace’s gas and electrical components for servicing. If an access panel cannot be incorporated, the alternative method of servicing the gas and electrical components is though the fireplace.
  • Page 60: Appendix 8 - Maintenance

    Appendix 8 - Maintenance Appendix 8 - Maintenance NOTICE Installation and Repairs • Installation and repairs on the fireplace and vent system must be done by an authorized Camina & Schmid Inc. qualified installer service agency or gas supplier on an annual basis. •...
  • Page 61: Glass Assemblies

    Appendix 8 - Maintenance Should the Vent system be disassembled for any reason, reinstall following the instructions provided with the installation. • Inspection of the vent system for obstructions and defects 16.3 Glass Assemblies NOTICE Glass Front • Do not operate this appliance with the glass front removed, cracked, or broken. •...
  • Page 62: Appendix 9 - Spare Parts And Accessories Overview

    Conversion kit LP Gas 0000003357 649275621055 Conversion kit NG gas 0000003356 649275930775 Front Pane inside replacement kit Ekko G U 60/14-19 0000003352 649275996498 Front Pane inside replacement kit Ekko G R/L 60/14-19 0000003353 649275612183 Side Pane inside replacement kit Ekko G U/R/L 60/14-19...
  • Page 63: Table 9: Overview Accessories

    Airbox L 2 connections 30 x 3 “ 0000003245 649275556296 Airbox AD 0000003246 649275825620 Accessories Set Ceramic Back Wall Ekko G U 60/14-19 0000003239 649275702884 Set Ceramic Back Wall Ekko G L and R 60/14-19 0000003240 649275873409 Set Ceramic Back Wall Lina G 60-19...
  • Page 64 Camina & Schmid Inc. 80 Pine street 24th Floor 10005 New York (NY) www.camina-schmid.com info@camina-schmid.de...

This manual is also suitable for:

Ekko g l 60/14-19Ekko g r 60/14-19Lina g 60-19

Table of Contents