Lotus LIBR.ISTR.CW70G Installation And Operating Instructions Manual

Gas grill for professional use

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Installation and operating instructions
GAS GRILL FOR PROFESSIONAL
USE
CW-74G CW-78G CWT-74G CWT-78G
Model LIBR.ISTR.CW70G
Code 563006702
Review 1
Edition date 09/11/2018
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lotus LIBR.ISTR.CW70G

  • Page 1 All manuals and user guides at all-guides.com Installation and operating instructions GAS GRILL FOR PROFESSIONAL CW-74G CW-78G CWT-74G CWT-78G Model LIBR.ISTR.CW70G Code 563006702 Review 1 Edition date 09/11/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020...
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................Technical data table........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation ......................... Electrical/gas connections ......................BURNERS TECHNICAL DATA TABLE (ITGB)................
  • Page 3: Introduction

    All manuals and user guides at all-guides.com INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 CW-7..G FIG. 2 CWT... A Data Plate C Gas connection Translation of the original instructions...
  • Page 4: Components

    All manuals and user guides at all-guides.com INTRODUCTION Components FIG. A 1 Injector 2 Extends drainage 3 Pilot 4 Ignition spark plug 5-6 Tap knob 7 Gas pipes 8 Gas tap 9 Piezoelectric 10 Fat collection pan 11 Burner 12 Tank  ...
  • Page 5 All manuals and user guides at all-guides.com INTRODUCTION FIG. B A Piezoelectric   FIG. C 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug   FIG. D Burner air adjustment Translation of the original instructions...
  • Page 6 All manuals and user guides at all-guides.com INTRODUCTION FIG. E 1 By-pass   Translation of the original instructions...
  • Page 7: Example Installation Of The Appliance

    All manuals and user guides at all-guides.com INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 8: General Information

    All manuals and user guides at all-guides.com GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 9: Technical Data Table

    All manuals and user guides at all-guides.com GENERAL INFORMATION Technical data table Technical data table CW S70G RATED GAS FITTING MODEL DIMENSIONS TOTAL GAS FLOW LAVA STONE (Kg) ISO 7-1 (kW) CW-74G 40x70x90h R 1/2GM CW-78G 80x70x90h R 1/2GM CWT-74G 40x70x29h R 1/2GM CWT-78G...
  • Page 10: Installation

    All manuals and user guides at all-guides.com INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 11 All manuals and user guides at all-guides.com INSTALLATION Installation operations, any conversion to other types of gas and start-up must only be   performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 12 All manuals and user guides at all-guides.com INSTALLATION   For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the burner is hot.
  • Page 13 All manuals and user guides at all-guides.com INSTALLATION Forced evacuation (fig.4) The gas supply to the appliance must be directly servo-controlled by the forced evacuation system and must stop if the flow rate drops below the values indicated in point 4.3 of the UNI-CIG 8723 standard. Resetting the gas supply to the appliance must be possible only by hand.
  • Page 14: Burners Technical Data Table (Itgb)

    All manuals and user guides at all-guides.com BURNERS TECHNICAL DATA TABLE (ITGB) 4 BURNERS TECHNICAL DATA TABLE (ITGB) Burners technical data table Technical data table - Burner CW S70G 12.68 kWh/KG 12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar...
  • Page 15: Instructions For Use

    All manuals and user guides at all-guides.com INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 16: Emptying The Container

    All manuals and user guides at all-guides.com INSTRUCTIONS FOR USE · Press and turn the gas cock knob to position "0". This control blocks the gas supply to both the main burner and the pilot burner   Emptying the container This rack should be checked regularly and emptied before it is full.
  • Page 17: Maintenance

    All manuals and user guides at all-guides.com MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 18: Minimum Setting

    All manuals and user guides at all-guides.com MAINTENANCE · Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly touches the tip of the thermocouple   Warning After conversion to another type of gas, update the technical data plate to indicate the type of  ...
  • Page 19 All manuals and user guides at all-guides.com MAINTENANCE Caution WHAT TO DO IN THE EVENT OF FAULTS:   Close the gas connection cock and/or switch off the power using the up-line device. Notify customer service.   Warning MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME:  ...
  • Page 20: Cleaning

    All manuals and user guides at all-guides.com CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections.