Page 31
STEP 40 Meter Calibration: Meter Calibration: Enter the Flow Meter Calibration Number that is labeled on your flow meter. The Flow Cal number for SurePoint flowmeters is on the serial number sticker on the side of the flowmeter. Press to continue.
Page 38
Configuration Setup STEP 67 STEP 68 These are Control Valve Settings: critical . Set these for SurePoint systems. Control Valve: PWM 12 volt PWM Frequency: 100 Select PWM Gain: 800 (decrease if rate is varying; increase to adjust more quickly.
Page 39
Configuration Setup Configuration Setup STEP 73 STEP 74 Pressure Sensor Calibration. Pressure Sensor Calibration. If using a SurePoint pressure transducer, set as If using a SurePoint pressure transducer, set as depicted. depicted. Press to continue. Press to continue.
Page 59
For SurePoint systems, Aux Valve Behavior will Control Valve Configuration and Feedback Type be set to Closed, Control Valve behavior will be for your operation. If using a SurePoint Pump, set to Closed. select PWM 12v. Feedback type will be set to Refer to the AgLeader Operator’s Manual for...
Page 63
UT Setup for ISO Rate Control STEP 51 STEP 52 From the drop-down menu, select Single Set From the drop-down menu, select Main. Point, if using a SurePoint Pressure Sensor. Press to continue. Press to continue. UT Setup for ISO Rate Control...