Smart outdoor integrated energy storage cabinet (53 pages)
Summary of Contents for Dyness TX5K-HM
Page 1
Quick Installation Guide Split-Phase Hybrid Inverter TX5K-HM/TX6K-HM/TX7.6K-HM TX9.6K-HM/TX11.4K-HM File version-20230718-V1.0-EN information might be subject to change without notice during product improving. V1.0...
Page 2
4.Before installation, check that the package contents are intact and complete compared to the packing list. Contact DYNESS or the distributor in case of any damaged or missing components. 5.The cable used must be intact and well-insulated. Operation personnel must wear proper personal protective equipment (PPE) all the time.
Disconnect the inverter from all the external power sources before maintenance Failure to observe any warnings contained in this manual may result in injury. Danger to life due to high voltages! Hot surface! Burn danger due to hot surface that may exceed 140 Products shall not be disposed of as household waste.
Scope of Delivery Upon receiving the hybrid inverter, please check if any of the items as shown below are missing or broken. Tubular terminal Spare Screw Wall-mounted Bracket Inverter GEN &DRY BMS&DI&EMS Expansion bolts Documents Dimension 8.7 in 19.1 in 28.7 in...
Page 6
F~ 140 0%~95%RH <15° 16.7 in 11.8 in 11.8 in 11.8 in 16.7 in...
Page 7
Mounting Step 1 Install the inverter on the wall using the provided wall-mounting bracket and expansion plug sets. The bearing capacity of the wall must be greater than 72.8lb. Otherwise, the wall may be unable to prevent the inverter from dropping. 7.87 in 3.74 in...
Page 8
Step 2 Carry the inverter by holding the heat sink on two sides and placing the inverter on the mounting bracket. Step 3...
Page 9
Step 3 SCREW OFF Recommended catheter: 1inch...
Page 14
Power On Without SCD BOX Inverter 25 A/400 V AC TX5K-HM/TX6K-HM breaker MAX Battery Depends on 32 A/400 V AC 32A/1100V Current(A) TX7.6K-HM/TX9.6K-HM household breaker DC Switch *1.2 loads 63 A/400 V AC DC breaker TX11.4K-HM breaker Power-on Sequence 5 → 2 → 1 → 4 → 3...
Page 15
Power On With SCD BOX Inverter 25 A/400 V AC TX5K-HM/TX6K-HM breaker MAX Battery 32 A/400 V AC 32A/1100V Current(A) TX7.6K-HM/TX9.6K-HM breaker DC Switch *1.2 DC breaker 63 A/400 V AC TX11.4K-HM breaker Power-on Sequence 2 → 1 → 4 → 3...
Page 16
Offical Website Digital Version Access Dyness Digital Energy Technology Co., LTD. Address: No.688, Liupu Road, Guoxiang Street, Wuzhong Economic and Technological Development Zone, Suzhou, Jiangsu, China. Email: Sales@dyness-tech.com Website: www.dyness-tech.com...