Page 1
JPEG XS IP Gateway CD-5550 Instruction Manual Ver. 1.00 ASTRODESIGN, Inc.
Page 2
Safety Precautions (Always Observe) Safety Precautions (Always Observe) Always observe the following precautions. Failure to do so can result in fires, electric shock, serious injury or death, and damage to property. Warning Indications and Their Meanings This manual uses the following warning indications. Before reading this manual, make sure that you understand the meaning of these indications.
Page 3
Safety Precautions (Always Observe) About Handling of this Unit About Frame Ground Do not install in a place with wobbling Be sure to share the frame ground (FG) prior to connecting to other The device may fall and cause injury or equipment.
Page 4
Safety Precautions (Always Observe) Do not touch liquid leaking from the LCD panel (LCD) ・ If the LCD panel is accidentally damaged Forbidden and the liquid (LCD) inside leaks out, be careful not to get it in your mouth, on your skin, or inhale the liquid.
Page 5
Thank you for purchasing the JPEG XS IP Gateway CD-5550. This instruction manual (hereinafter referred to as "this manual") explains how to use CD-5550 and precautions for use. Please be sure to read this manual before use to ensure correct use.
Page 6
Contents Contents Safety Precautions (Always Observe) ....2 4.4 Settings ............20 Warning Indications and Their Meanings ....2 4.4.1 MEDIA PORT ........20 If the Unit Malfunctions or Trouble Occurs ....4 4.4.2 SENDER (SDI -> IP) ......21 Before Operation ............
Page 7
Chapter 1 About this unit Chapter 1 About this unit 1.1 Overview This device is a JPEG XS IP Gateway that supports the JPEG XS codec for SDI/IP interconversion. 1.2 Features ⚫ Compliant with Video Over IP standards ➢ Video data can be transmitted using SMPTE ST 2110-22 (Compressed Video) ➢...
Page 8
Chapter 1 About this unit System Diagram JPEG XS encoding JPEG XS decoding...
Page 9
Chapter 1 About this unit 1.4 Names and Functions of Parts 1.4.1 Front View ③ ④ ⑦ ② ⑤ ⑥ ① Number Name Description Port for sending and receiving the unit's media (Video) and PTP Two 10GbE (SFP+ cage) ports (SFP+ module not included) ①...
Page 10
Chapter 1 About this unit 1.4.2 Back View ⑥ ⑧ ① ② ③ ④ ⑤ ⑩ ⑦ ⑨ Number Name Description Power (AC 100-240V 50/60Hz) IN ① AC IN 1/2 PSU (Power Supply Unit) is replaceable (hot-swappable) Supports power supply redundancy Frame ground ②...
Page 11
The I/O pins used differ depending on the mode to be executed. Refer to the system configuration diagram. 2.2 Start up This unit ⚫ After completing all the connections, turn the power on. The ASTRO logo will display on the screen. Shut down This unit ⚫...
Page 12
Chapter 3 Front Menu Settings Chapter 3 Front Menu Settings This chapter explains how to operate the front panel and the menus that are displayed. 3.1 Basic Operation Method The menu can be operated using the MENU and ESC buttons on the front of the machine. Press MENU.
Page 13
Chapter 3 Front Menu Settings 3.2 Home Screen After the unit completes startup, the home screen shown in the figure below will display. ③ ④ ⑤ ① Number Item 1 Item 2 Item 3 Display description Description STATUS ① OK / ERR Displays the status of the power supply unit.
Page 14
Chapter 3 Front Menu Settings Menu Screen Items with a ▲ mark at the beginning of the line are status display items. These settings cannot be changed. Contents Level 1 Level 2 Level 3 Level 4 Description (initial setting: underlined) SETTINGS MGMT LACP...
Page 15
Sets the mode for the next startup. INITIALIZE ALL SETTINGS Execute ? OK / CANCEL Resets all settings. MAINTENANCE INFORMATION Product Model CD-5550 Displays the product model number. ▲ Product S/N ******* Displays the product serial number. ▲ FAN1 S/N *******-* Displays the FAN1 serial number.
Page 16
Chapter 4 WEB GUI Settings Chapter 4 WEB GUI Settings This chapter describes how to access WEB GUI window and the displayed menus. Access Method It can be accessed by entering the MGMT IP address of this device in the URL field of the web browser. 4.2 Supported WEB browsers The following browsers have been verified.
Page 17
Chapter 4 WEB GUI Settings 4.3.1 PTP Displays the PTP status. 4.5.4 PTP Status for more Item Description Settings Switches to the PTP setting screen. Status Switches to the PTP status window. 4.3.2 MEDIA1 RX RTP This status is displayed only when operating in Decode. Displays the RTP receive status.
Page 18
Chapter 4 WEB GUI Settings 4.3.6 Alarm Indicates whether an alarm has gone off. Item Display description Description Settings Switches to the corresponding setting screen. Total Alarm OK / Error Will display as Error if any alarms are Error alarms. Open/Close Switches between hiding and displaying the alarm content.
Page 19
Chapter 4 WEB GUI Settings 4.3.7 GPO Displays GPO status. Item Display description Description Settings Switches to the corresponding setting screen. GPO status GPO1 Open / Close Will display as Open if normal, Close if abnormal. GPO2 Open / Close GPO3 Open / Close GPO4...
Page 20
Chapter 4 WEB GUI Settings 4.4 Settings 4.4.1 MEDIA PORT Set the MEDIA PORT IP address. Contents Setting items Description (initial setting: underlined) MEDIA 1 Mode STATIC / DHCP Sets IP address mode. Sets IPv4 address. IP Address 192.168.1.4 Sets IPv4 address. SUBNET MASK 255.255.255.0 Sets IPv4 subnet mask.
Page 21
Chapter 4 WEB GUI Settings 4.4.2 SENDER (SDI -> IP) Sets the compression/destination IP and other settings. Settings can only be configured when operating in Encode. Contents Setting items Description (initial setting: underlined) COMMON RTP Payload Type 96~127 96 Sets RTP Payload Type. Compression ratio 5~200 5 Sets the compression rate.
Page 22
Chapter 4 WEB GUI Settings 4.4.3 RECEIVER (IP -> SDI) Configures settings such as the reference, SDI output, and receiving IP address. Settings can only be configured when operating in Decode. Contents Setting items Description (initial setting: underlined) REFERENCE Source PTP / REF IN / FREE RUN Sets the reference.
Page 23
Chapter 4 WEB GUI Settings 4.4.4 PTP Sets PTP. Contents Setting items Description (initial setting: underlined) Reset PTP Resets PTP. Domain Number 0~127 Sets the domain number of the PTP to be received. Announce Timeout (log) 0.0625Hz(4) /0.125Hz(3) / 0.25Hz(2) Sets the timeout period for PTP announcement / 0.5Hz(1) / 1Hz(0) / 2Hz(-1) / 4Hz(-2) messages.
Page 24
Chapter 4 WEB GUI Settings 4.4.5 ALARM Sets the alarm. For details on the alarms, see 5.3 List of Alarm Conditions. Contents Setting items Description (initial setting: underlined) Alarm Preset Default Sets Alarm Preset settings to default settings. Alarm 1 ON / OFF Assigns the target item's alarm to Alarm1.
Page 25
Chapter 4 WEB GUI Settings 4.5 Status 4.5.1 MEDIA Status Displays the Media Traffic status. Item Display description Description Reset Cumulative Statistics All cumulative values (Cumulative) are reset to 0. TX Traffic Total Bits Displays the number of Bits per second and the cumulative number of sent packets.
Page 26
Chapter 4 WEB GUI Settings Item Display description Description Undersize Packets Displays the number of packets per second and their cumulative number of undersized packets. Undersize Packets Displays the number of packets per second and their cumulative number of undersized packets. Undersize Packets Displays the number of packets per second and their cumulative number of undersized packets.
Page 27
Chapter 4 WEB GUI Settings Item Display description Description SYSTEM RX IGMP Status IGMP Membership Query Displays the number of times of Membership Querys received per second and the cumulative number, IGMPv1 Membership Displays the number of IGMPv1 Membership Report received Report per second and the cumulative number of received messages.
Page 28
Chapter 4 WEB GUI Settings 4.5.2 RTP Status Displays the status of RTP. Displayed only when operating in Decode. Item Display description Description Reset Cumulative Statistics All cumulative values (Cumulative) are reset to 0. RX RTP RTP Bits Displays the number of Bits per second of received RTP and its cumulative number.
Page 29
Chapter 4 WEB GUI Settings 4.5.3 SDI Status Displays the status of SDI IN when operating in Encode. Displays the status of SDI OUT when operating in Decode. Item Display description Description SDI IN RESOLUTION For supported formats, Displays the input resolution. FRAME RATE refer to 7.1.1...
Page 30
Chapter 4 WEB GUI Settings 4.5.4 PTP Status Displays the PTP status. Item Display description Description Reset Cumulative Statistics Resets the following statuses: "PTP Lock", " T1-T4 Sequence Error", " T3-T4 SequenceID Error", " Announce PTP Timeout" Common Media used MEDIA 1 / - Displays MEDIA currently in use.
Page 31
Chapter 4 WEB GUI Settings 4.5.5 System Status Displays the System status. Item Display description Description GENLOCK ※Displayed only when decode is selected. Mode PTP / REF IN / Displays the reference in use. FREE RUN Detect Detect / Not Detect Displays the reference signal detection status.
Page 32
Chapter 4 WEB GUI Settings System 4.6.1 Maintenance Displays version information. Item Display description Description Version ▲SYS FPGA *.*.* Displays the System FPGA version. ▲SYS PMIC *.*.* Displays the System F/W version. ▲MAIN FPGA *.*.* Displays the Main FPGA version. ▲MAIN PMIC *.*.* Displays the MAIN F/W version.
Page 33
Chapter 4 WEB GUI Settings 4.6.2 Net Tools Sends a PING and executes a traceroute (acquires route information to the destination). Set Value Setting items Description (initial setting: underlined) PING Source MEDIA 1 Sets the MEDIA to which the ping is sent. Count 1~100 3 Sets the number of transmissions.
Page 34
Chapter 4 WEB GUI Settings 4.6.3 Log Displays the log. Setting items Description PING DownLoad Downloads the log. Log display Displays a maximum of log 500 entries.
Page 35
Chapter 5 Alarm Function Chapter 5 Alarm Function This chapter describes the alarm function and conditions under which it occurs. ALARM LED ALARM LED (1.4.1 Front View) lights up when any Warning or Error occurs for any or all items in the If something goes wrong.
Page 36
Chapter 5 Alarm Function Item 1 Item 2 Warning Conditions Error Conditions A T1-T4 Sequence fault has Genlock ✓ T1-T4 occurred. *2 Sequence Error A T3-T4 Sequence ID failure ✓ T3-T4 occurred *2 SequenceID Error An Announce PTP Timeout has ✓...
Page 37
Chapter 6 Troubleshooting Chapter 6 Troubleshooting This chapter explains what steps to take when your device is not responding properly. When the Product is Not Operating Normally If the unit does not operate normally, check the following table, and take appropriate action. If the problem persists, please contact your dealer or ASTRODESIGN, Inc.
Page 38
Chapter 7 Specifications of this unit Chapter 7 Specifications of this unit This chapter describes the specifications of this unit. 7.1 Specifications Items Specifications IP interface ・10GbE(SFP+): 2 system ※Functions related to port 2 will be supported in the future. Supported IP formats ・SMPTE ST 2110(-10,-22) Video interface...
Page 39
Chapter 7 Specifications of this unit 7.1.2 GPO Items Specifications Shape D-SUB 9 pin-recessed connector Structure Semiconductor relay Specifications Open/Close max. 50V/0.5A Operation Close at alarm output Pin Assignments See below Pin Assignments Items Specifications OUT1 When an alarm occurs, 1 pin and 6 pin close OUT2 When an alarm occurs, 2 pin and 7 pin close OUT3...
Page 41
Chapter 9 Revision history Chapter 9 Revision history Ver. Date Page Item Contents 1.00 2023/11/01 First edition...
Page 42
CD-5550 Instruction Manual Ver. 1.00 An incorrectly collated manual or a manual with missing pages will be replaced. ● ● All copyrights of this manual are the property of ASTRODESIGN, Inc. ● The content of this manual may not be used or copied in whole or in part without permission.
Need help?
Do you have a question about the CD-5550 and is the answer not in the manual?
Questions and answers