Level Pro ICON ProScan 3 Series Operating Manual

Continuous radar level sensor

Advertisement

Quick Links

ProScan
®
3 Series
Continuous Radar Level Sensor (80GHz)
Operating Manual
Read the user's manual carefully before starting to use the unit.
Producer reserves the right to implement changes without prior notice.
24-0167 © Icon Process Controls Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICON ProScan 3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Level Pro ICON ProScan 3 Series

  • Page 1 ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Operating Manual Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice. 24-0167 © Icon Process Controls Ltd.
  • Page 2: Table Of Contents

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Table of Contents Safety Information Product Description Working Principle Technical Specif ications Wiring Connection ProScan 3 to TVL Display Connection ® Sensor Positioning Programming Display Display Introduction Basic Setup Connection Bluetooth Device to ProScan ®...
  • Page 3: Safety Information

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Safety Information De-pressurize and vent system prior to installation or removal Confirm chemical compatibility before use DO NOT exceed maximum temperature or pressure specifications ALWAYS wear safety goggles or face-shield during installation and/or service DO NOT alter product construction Please always observe the following safety instructions! Please pay attention to the safety instructions with the following pictograms and signal words in these operating instructions :...
  • Page 4: Working Principle

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Working Principle The ProScan® 3 (80GHz) radar is a transmitter Emitted Signal for continuous level measurements using fast sweep Frequency Modulated Continuous Wave (FMCW) technology. The transducer of 3º Angle radar continuously emits signal sweeps with Signal a constant frequency towards the liquid Reaching...
  • Page 5: Wiring Connection

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Wiring Connection The sensor power supply and current signal share the same two-wire shielded cable. The sensor supply voltage should never exceed 24 VDC. Always provide complete electrical and physical separation between the sensor supply circuit and the main circuit.
  • Page 6: Proscan ® 3 To Tvl Display Connection

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) ProScan 3 to TVL Display Connection ® TVL Displays ProScan ® ENTER MENU Power Supply 120VAC Terminal 1 & 2 wire Terminal 8 Black wire Terminal 11 ProScan ® 3 Blind to TVL Display Connection Power Supply 120VAC...
  • Page 7: Sensor Positioning

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Sensor Positioning On a plastic or FRP tanks, make sure the sensor is not too close to the sidewall. Avoid metallic objects outside of the vessel that can be detected by the sensor. Ensure that the radar signal strikes the surface of the liquid at a 90°...
  • Page 8: Programming Display

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Programming Display Measuring the tank is one of the most important aspects in configuring the sensor. When measuring the tank, take into account the location of the sensor with respect to fittings, risers, dome tops and bottoms, and identify where the measurements are taken from the sensor.
  • Page 9: Basic Setup

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Basic Setup & to change Selection / Values STEPS DISPLAY OPERATION When Power is on, Display will Show the Home Screen 192.5 Home Screen Press to go to Main Menu Press Main Menu User Para.
  • Page 10: Device Unit Settings

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Connecting ProScan ® 3 to Bluetooth Application Install RadarMe App in your Device RadarMe RadarMe Make Sure your Device Bluetooth is ON Home Home Home ICON12XXX UPDATE DEVICE LIST RadarMe ICON12XXX Level(m) Level(m) 35.7873...
  • Page 11: Basic Parameters Settings

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Basic Parameters Settings Home Basic Parameters ICON12XXX ICON12XXX ICON12XXX Basic Parameters Range(inch) 120.00 Level(inch) 35.7873 Migration Amount(inch) Advanced Parameters Distance(inch) 84.2124 4mA Location(inch) System Settings Current(mA) 8.771 20mA Location(inch) 119.9998 Percentage(%) 29.82 Range 120 (inch) 4.0157...
  • Page 12: Dimensions

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Basic Parameters Home ICON12XXX ICON12XXX ICON12XXX Measurement Basic Parameters Location Range(inch) 120.00 Level(inch) 35.7873 Migration Amount(inch) 20 mA 100% Advanced Parameters Distance(inch) 84.2124 Max Config 4mA Location(inch) System Settings Current(mA) 8.771 110.00 20mA Location(inch) Percentage(%)
  • Page 13: Warranty, Returns & Limitations

    ProScan ® 3 Series Continuous Radar Level Sensor (80GHz) Warranty, Returns & Limitations Warranty Icon Process Controls warrants to the original purchaser of its products that such products will be free from defects in materials and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls for a period of one years from the date of sale of such products.

Table of Contents