Summary of Contents for thomann t.tracks VM-100

  • Page 1 VM-100 Voltage Meter...
  • Page 2 Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 Internet: www.thomann.de 30.10.2023, ID: 107459 (V3)
  • Page 3: Table Of Contents

    Table of contents Table of contents General information..........................5 1.1 Symbols and signal words....................... 5 Safety instructions............................. 7 Features................................9 Installation..............................10 Connections and operating elements................... 11 Maintenance.............................. 13 Technical specifications........................15 Protecting the environment......................16 VM-100 Voltage Meter...
  • Page 4 VM-100 Voltage Meter...
  • Page 5: General Information

    Our products and documentation are subject to a process of continuous development. They are therefore subject to change. Please refer to the latest version of the documentation, which is ready for download under www.thomann.de. 1.1 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this document.
  • Page 6 General information Signal word Meaning DANGER! This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided. WARNING! This combination of symbol and signal word indicates a pos‐ sible dangerous situation that can result in death or serious injury if it is not avoided.
  • Page 7: Safety Instructions

    Safety instructions Safety instructions Intended use This device is designed to distribute supply voltage to connected devices and illuminate a rack. Use the device only as described in this user manual. Any other use or use under other oper‐ ating conditions is considered to be improper and may result in personal injury or property damage.
  • Page 8 Safety instructions DANGER! Danger to life due to electric current! A short circuit could lead to a fire hazard and risk of death. Do not modify the mains cable or the plug! In case of isolation damage, disconnect immediately the power supply and arrange repair. If in doubt, seek advice from a qualified electrician. NOTICE! Risk of fire due to covered vents and neighbouring heat sources! If the vents of the device are covered or the device is operated in the immediate vicinity of other heat sources, the device can over‐...
  • Page 9: Features

    Features Features Power supply for up to eight electrical loads with IEC sockets Filters to protect the connected units against interference and voltage peaks Resettable electronic overload fuse Two dimmable rack lights Supply voltage monitoring via tricoloured LED chain VM-100 Voltage Meter...
  • Page 10: Installation

    Installation Installation Unpack and check carefully there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the product against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively.
  • Page 11: Connections And Operating Elements

    Connections and operating elements Connections and operating elements Front and back POWER LIGHTS DIMMER VM-100 PROTECTION PULL PULL OUTLETS ö & VM-100 Voltage Meter...
  • Page 12 Connections and operating elements 1 [LIGHTS] | Rack illumination switch 2 [DIMMER] | Stepless dimmer control for rack illumination 3, 5 Extensible rack lights. Pull out the rack light and adjust the light beam as desired. 4 Indicates the currently available mains voltage in a range of 190 V…250 V 6 [PROTECTION] | Resettable fuse for the power supply outlets on the back 7 [POWER OUTLET] | On/off switch for the power supply outlets on the back 8 Mains connection...
  • Page 13: Maintenance

    Maintenance Maintenance Replacing the lamp DANGER! Risk of death from electrical current! The device contains parts where high voltage is present. Disconnect the device completely from the power supply before opening or removing covers. Do not reconnect the unit until the covers are fully refitted and tightly closed.
  • Page 14 Maintenance Replace the lamp. Screw the cap back onto the end of the rack light. Reconnect the device to the mains. VM-100 Voltage Meter...
  • Page 15: Technical Specifications

    Technical specifications Technical specifications Output connections Power supply of further devices 8 × IEC chassis plug Supply voltage 220 - 240 V 50/60 Hz Fuse 10 A, resettable Maximum connected load 2200 W Mounting options Rack mounting, 1 RU Dimensions (W × H × D) 482 mm ×...
  • Page 16: Protecting The Environment

    Protecting the environment Protecting the environment Disposal of the packing material Environmentally friendly materials have been chosen for the packaging. These materials can be sent for normal recycling. Ensure that plastic bags, packaging, etc. are disposed of in the proper manner. Do not dispose of these materials with your normal household waste, but make sure that they are collected for recycling.
  • Page 17 Repairing a device or passing it on to another user is an ecologically valuable alternative to disposal. You can return your old device to Thomann GmbH at no charge. Check the current conditions on www.thomann.de. If your old device contains personal data, delete those data before disposing of it.
  • Page 18 Notes VM-100 Voltage Meter...