Page 2
ARMATURA supplied product vests in and is the property of ARMATURA. The contents hereof should not be used or shared by the receiver with any third party without express written permission of ARMATURA.
Page 3
ARMATURA in no event shall be liable to the user or any third party for any incidental, consequential, indirect, special, or exemplary damages, including, without limitation, loss of business, loss of profits,...
Page 4
User Manual About the Company ARMATURA is a leading global developer and supplier of biometric solutions which incorporate the latest technologies on biometric hardware design, algorithm research and software development. ARMATURA holds numerous patents in the field of biometric recognition technologies. Its products are primarily used in business applications which require high-secured, high-accurate and fast matching and identification processes.
Product Introduction Overview AMT-PVM-10 is a single-lens near infrared light camera module that supports to capture the palm print and palm vein grayscale images for recognition process. The module is configured with near-infrared LED lights, wide dynamic image sensor, and aspherical distortion-free camera lens.
Figure 3.2 Example of a palm registration image Application Scenarios The AMT-PVM-10 module is is optimized on its physical structure for the purpose of the built-in design and integration, facilitating easy and fast integration into third-party hardware device. Kept the integration thought into design, the module can be built into a host device using a single USB cable which provides both the power supply and data communication, this approach simplifies the integration development work considerably.
Answer: First, open the computer management from your windows system to check if AMT-PVM-10 has been successfully connected. Next, check whether the connection button in the demo (see attached software package) is enabled or not. If these two potential problems are excluded, please contact the technical support team in time to analyze the other reasons such as hardware failure, demo issues and so on.
Page 19
2. What shall I do if it fails to register the user? Answer: Firstly, please confirm that AMT-PVM-10 has been already connected to the system, and then open the demo for initialization. Next, verify if the palm position, angle, and the palm placing distance are proper.
Need help?
Do you have a question about the AMT-PVM-10 and is the answer not in the manual?
Questions and answers