Differential mems dc accelerometer, 90 mv/g, 30 g, 10 ft integral cable (17 pages)
Summary of Contents for PCB Piezotronics 3991B1160KG
Page 1
Model 3991B1160KG HIGH AMPLITUDE MEMS SHOCK ACCELEROMETER Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
3991 Series Piezoresistive Shock Accelerometer Operating Guide Introduction display a slight linear decrease in sensitivity as temperature increases. TZS – Thermal Zero Shift, the change in ZMO due to This Operating Guide contains information that will familiarize the user with the basic operation and installation of temperature.
Page 7
3991 Series Piezoresistive Shock Accelerometer Operating Guide they are preferred for applications in which integration from with unwanted static strain, possibly resulting in zero-shift acceleration to velocity or displacement may be performed: during a shock measurement. Rigid-body motion penetration studies Prepare a smooth, flat mounting surface and, if applicable, drill and tap mounting holes according to the Sensor ...
Page 8
3991 Series Piezoresistive Shock Accelerometer Operating Guide Sensor Verification information, such as model number, serial number and description of the problem, available. Generally the ZMO of a PR transducer is a good measure of the health of the transducer. Input Resistance (from Red to Customers outside the U.S.
Page 9
Model Number Revision: D HIGH AMPLITUDE MEMS SHOCK ACCELEROMETER ECN #: 48068 3991B1160KG Performance ENGLISH OPTIONAL VERSIONS Sensitivity(± 50 %)(at 10 VDC excitation) 0.003 mV/g 0.0003 mV/(m/s²) Optional versions have identical specifications and accessories as listed for the standard model Sensitivity 0.0003 mV/V/g...
Page 10
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION .56 [14.2] without the written consent of PCB Piezotronics Inc. REMOVED ITAR CONTROL STAMP 48068 .375 [9.53] .19 [4.8] ...
Page 11
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. -SEE SHEET 1- "SERVICE LOOP" TO ALLOW MOTION WITHOUT PULLING...