Contents Overview 1 01 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions Important safety notes Safety labels Before Installation 3 01 Unpacking and unit placement Installation 4 01 Connecting to power supply Optional Interfacing Operation 5 01...
This does not signify a dangerous or harmful situation. Refer to manual when this symbol is displayed. Visit our website at www.bofa.co.uk for on-line help. Or contact the helpline on +44 (0) 1202 699444, Electrical Safety Mon-Fri, 9am-5pm.
Page 7
Serial Number Label Safety Instructions Warning and Information labels Location: Next to mains inlet. The following listing details labels used on your AD Nano+ Meaning: This label contains a variety of information about unit. the extraction unit, including: Goggles, Gloves & Mask Label ...
Before installation 3. With the unit in position lock the 2 front castors. Inner transit packaging removal & unit placement Before installation, check the extraction unit for damage. All packaging must be removed before the unit is connected to the power supply. Caution Please read all instructions in this manual before using Do not block or cover the cooling vents on the unit, as this...
The supply cord should only be replaced by a BOFA engineer as an electrical safety test may be required after replacement. The AD Nano+ MUST be connected to a properly earthed outlet.
Page 10
Override Installation Enables the extractor to operate fully with or without either DC voltage input or the Volt free input. The override feature can be toggled On / Off by a switch mounted on the internal motor access panel (see below for switch location) Switch in “On”...
To set the airflow Operation Hold down the Up and Down arrows on the front panel for 5 seconds. The green LED will now start to flash, indicating that the machine is now in set mode. You can now increase or decrease the flow by holding down either the up or down arrow.
Filter Information Maintenance A log of filter changes should be maintained by the user. The filters require attention when the display shows the configuration shown on the next page or when the extractor no longer removes fume efficiently. It is recommended that a spare set of filters are kept on site Maintenance UK to avoid prolonged unit unavailability.
Page 13
Maintenance To remove and replace the combined filter follow the procedure detailed below. Isolate the electrical supply to the extractor 2. Open the door of the unit. Remove the upper (combined) filter. 4. Fit new filter. Filter Replacement Close the door and fasten the latches. During use, the AD Nano+ will alert the user when its filter 6.
To maintain performance it is important that the filters are associated risks defined. replaced with identical BOFA filters. To re-order please refer The thresholds for these to the Filter number printed on the filter installed in your risks can then be compared extraction unit.