aiko -P MAH72Mw Series Installation Manual

aiko -P MAH72Mw Series Installation Manual

Pv module
Hide thumbs Also See for AIKO-P MAH72Mw Series:

Advertisement

Shenzhen Aiko Digital Energy
Technology Co., Ltd.
PV Module Installation Manual
Aiko Digital Energy Technology reserves the right to change this manual
without prior notice.
Please log on to the official website of AIKO digital power for the
latest version of the installation manual,
URL:http://www.aikosolar.com
.
1 / 28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIKO-P MAH72Mw Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for aiko AIKO-P MAH72Mw Series

  • Page 1 PV Module Installation Manual Aiko Digital Energy Technology reserves the right to change this manual without prior notice. Please log on to the official website of AIKO digital power for the latest version of the installation manual, URL:http://www.aikosolar.com 1 / 28...
  • Page 2 Applicable module models Structure of modules AIKO-Pxxx-MAH72Mw AIKO-Pxxx-MAH72Mb AIKO-Pxxx-MAH60Mw AIKO-Pxxx-MAH60Mb AIKO-Pxxx-MAH54Mw AIKO-Pxxx-MAH54Mb AIKO-Axxx-MAH72Mw AIKO-Axxx-MAH72Mb AIKO-Axxx-MAH60Mw AIKO-Axxx-MAH60Mb Single glass photovoltaic modules AIKO-Axxx-MAH54Mw AIKO-Axxx-MAH54Mb AIKO-Bxxx-MAH72Mw AIKO-Bxxx-MAH72Mb AIKO-Bxxx-MAH60Mw AIKO-Bxxx-MAH60Mb AIKO-Bxxx-MAH54Mw AIKO-Bxxx-MAH54Mb AIKO-Gxxx-MCH72Mw AIKO-Gxxx-MCH54Mw 2 / 28...
  • Page 3 (hereinafter referred to Shenzhen Aiko Digital Energy Technology Co., Ltd. Important Safety as " Aiko "). During module installation and routine maintenance, please Information comply with all safety precautions and local laws and regulations specified in this manual. ...
  • Page 4: Table Of Contents

    CONTENTS 1、Overview ....................... 2、Regulation and rules ....................3、General information ....................... 5 Module identification ................……..…………..5 3.2 Wiring mode ........................7 3.3 General safety ........................7 3.4 Electrical safety ......................... 8 3.5 Operational safety ......................9 3.6 Fire safety ........................10 4、Installation conditions ......................
  • Page 5: 1、Overview

    If the patent right or the rights of a third party are infringed due to the use of modules, AIKO will not bear any relevant responsibilities. AIKO reserves the right to change the product manual and this installation manual without prior notice.
  • Page 6: 3、General Information

    3、General information 3.1 Module identification Three kinds of visual labels provided by AIKO’s modules: Nameplate:Product type, rated power under standard test conditions (STC), rated current, rated voltage, open circuit voltage, short circuit current under STC, certification mark, maximum system voltage and other information Serial number:Each module has a unique serial number.
  • Page 7 Nameplate Bar code label 7 / 28...
  • Page 8: Wiring Mode

    3.2 Wiring mode The junction box of AIKO ABC photovoltaic module is located in the middle. Please refer to the following table for the series connection mode of various modules. 3.3 General safety The design of AIKO PV module complies with IEC-61215、IEC-61730、CSA C22.2 No. 61730 and UL 61730 international standards.
  • Page 9: Electrical Safety

    Under the sunlight, whether the module is connected with the electrical system or not, it can generate direct current, and touching the live parts of the module (such as connectors) may cause casualties. Avoid direct contact with photovoltaic modules, which may cause electric shock or cuts. The installation of PV modules shall comply with the laws and regulations clearly stipulated by the relevant regions and countries where the PV modules are installed.
  • Page 10: Operational Safety

    The installation of PV module array must be carried out under the condition of electrical safety. During installation, the voltage of PV modules in series shall not exceed the maximum system voltage. It is forbidden to plug connectors of different manufacturers and models into each other. Please do not use conventional PV modules to replace roof and wall materials.
  • Page 11: Fire Safety

    aluminum alloy frame, which may lead to frame corrosion and affect the load resistance and long- term reliability of the frame. It is strictly prohibited to repair or refit PV modules by yourself. The surface of the touching photovoltaic module should be smooth, without sharp edges, burrs, etc.
  • Page 12: 4、Installation Conditions

    4、Installation conditions 4.1 Installation site and working environment AIKO PV modules are recommended to be installed in an environment where the operating ambient temperature is -20 ° C ~ 50 ° C. the limiting operating ambient temperature of PV modules is -40 °...
  • Page 13: Inclination Angle Selection

    4.2 Inclination angle selection The inclination angle of PV module refers to the included angle between PV module and horizontal ground. Different projects choose different installation inclination angles according to local conditions. Each PV module of the same array must have the same direction and angle.
  • Page 14: Mechanical Installation

    PV modules must be installed according to the following suggestions and examples. If there are other installation methods, please consult Shenzhen AIKO digital energy in advance and obtain written consent, otherwise the warranty will be invalid.
  • Page 15: Clamp Mounting And Corresponding Loads

    (more details, please contact AIKO technical personnal) The applied value of torque should refer to mechanical design standard and the bolt type customer is using, for example: M8: 16-20 N•m.
  • Page 16 Installation area D Installation PV module size Load PV module model 35/40mm Method L*W*H(mm) 30mm frame frame +5400/-2400 305≤D≤405 360≤D≤460 AIKO-Gxxx-MCH54Mw 1802*1134×30/35/40 AIKO-Axxx-MAH54Mb +5400/-2400 305≤D≤405 360≤D≤460 1757×1134×30/35/40 AIKO-Axxx-MAH54Mw 1722×1134×30/35/40 AIKO-Axxx-MAH54Mb +5400/-2400 295≤D≤395 350≤D≤450 AIKO-Axxx-MAH54Mw 1706×1134×30/35/40 AIKO-Bxxx-MAH54Mb AIKO-Bxxx-MAH54Mw 1722×1134×30/35/40 +5400/-2400 295≤D≤395 350≤D≤450...
  • Page 17: Bolts Mounting

    2278×1134×35/40 AIKO-Axxx-MAH72Mb +5400/-2400 400≤D≤500 AIKO-Axxx-MAH72Mw 2255×1134×35/40 AIKO-Bxxx-MAH72Mb AIKO-Bxxx-MAH72Mw 2278×1134×35/40 +5400/-2400 400≤D≤500 AIKO-Pxxx-MAH72Mb 2255×1134×35/40 AIKO-Pxxx-MAH72Mw Note: The installation method shown in the above table is based on the test results. 5.2.3 Bolts mounting Single glass modules can be installed by bolts base on rails. Using bolts to fix the module on the bracket through the mounting holes at the back of module’s frame.
  • Page 18: Single Glass Modules Bolt Mounting Diagram And Corresponding Loads

    The beam is perpendicular to the long frame The beam is parallel to the long frame PV Module size 4 inner mounting holes 4 outer mounting holes Module type L*W*H(mm) AIKO-Gxxx-MCH54Mw 1802×1134×30/35/40 External 4-hole bolt 1757×1134×30/35/40 +5400/-2400 AIKO-Axxx-MAH54Mw installation 1722×1134×30/35/40 AIKO-Axxx-MAH54Mb 1706×1134×30/35/40...
  • Page 19: 6、Electrical Installation

    Please see the PV module product specifications for the electrical performance parameters of PV modules of AIKO digital energy. There is ± 3% tolerance between the nominal values of the electrical performance parameters of photovoltaic modules such as Isc, Voc and Pmax at the standard test conditions.
  • Page 20: Cables And Wiring

    models cannot be connected in a string. When the PV modules are connected in a series, the final voltage is the sum of the single PV modules. When the PV modules are connected in parallel, the final current is the sum of the single PV modules, as shown in the figure below.
  • Page 21: Connector

    The solar PV module of AIKO adopts special PV cables with a cross-sectional area of 4mm2 or more and UV protection. All other cables used to connect the DC system shall have similar (or higher) specifications.
  • Page 22: 8、Pv Module Maintenance

    The PV modules must be regularly inspected and maintained, especially within the warranty period, which is the responsibility of the user. And notify AIKO' customer service personnel as soon as possible in case of any damage or other significant abnormalities of PV modules.
  • Page 23: Visual Inspection

    8.2 Visual inspection Visually inspect the PV module for appearance defects, such as: Whether the photovoltaic module glass is broken; Whether the photovoltaic module backplane is cracked or otherwise abnormal; Whether the junction box is damaged and whether the cable is damaged; Whether the PV module is covered by foreign matters and shadows;...
  • Page 24 52.80 44.61 13.55 12.78 1500 52.90 44.71 13.61 12.86 1500 53.00 44.81 13.67 12.94 1500 53.10 44.91 13.73 13.03 1500 AIKO-Axxx-MAH72Mw 53.79 44.48 14.03 13.27 1500 53.89 44.58 14.11 13.35 1500 53.99 44.68 14.20 13.44 1500 54.09 44.78 14.28 13.52 1500 54.19...
  • Page 25 52.23 43.70 13.31 12.36 1500 52.24 43.80 13.32 12.44 1500 52.25 43.90 13.33 12.53 1500 52.26 44.00 13.34 12.61 1500 AIKO-Bxxx-MAH72Mb 52.27 44.10 13.35 12.70 1500 52.30 44.20 13.40 12.78 1500 52.40 44.30 13.46 12.87 1500 52.50 44.40 13.53 12.95 1500 52.60...
  • Page 26 43.90 37.07 13.39 12.54 1500 44.00 37.17 13.45 12.64 1500 44.10 37.27 13.51 12.74 1500 44.79 37.03 13.74 12.97 1500 AIKO-Axxx-MAH60Mb 44.89 37.13 13.84 13.07 1500 44.99 37.23 13.94 13.17 1500 45.09 37.33 14.04 13.27 1500 45.19 37.43 14.13 13.37 1500 45.29...
  • Page 27 39.55 33.31 13.55 12.61 1500 39.65 33.41 13.61 12.72 1500 39.75 33.51 13.67 12.83 1500 39.85 33.61 13.73 12.94 1500 AIKO-Axxx-MAH54Mw 40.29 33.30 14.01 13.22 1500 40.39 33.40 14.11 13.33 1500 40.49 33.50 14.21 13.44 1500 40.59 33.60 14.31 13.55 1500 40.69...
  • Page 28 37.50 31.90 13.92 13.18 1500 40.27 33.38 14.80 13.94 1500 40.37 33.48 14.86 14.05 1500 40.51 33.58 14.93 14.15 1500 AIKO-Gxxx-MCH54Mw 40.65 33.68 15.00 14.26 1500 40.79 33.78 15.07 14.37 1500 40.93 33.88 15.14 14.47 1500 41.07 33.98 15.21 14.58...

Table of Contents