Installation:
Place the Quick Install Guide on the wall in the desired location to determine the
spacing and placement of the mounting holes on the wall. A carpenters level
should be used to insure that the O3 Pure LS is mounted level in the horizontal
plane. (Fig. c)
Mark the location of the two mounting holes on the wall with a pencil. Drill appropriate
sized holes for the screws or mollies in each marked location. Install the screws
leaving
them
protruding
from
the
wall
by
about
1/4
inch.
It
is
recommended that the mounting hole on the right side of the O3 Pure LS (above the
water inlet/outlet) be mounted to a wall stud, if possible. A set of mounting
hardware (screws and molly's) have been provided. If it is not possible to mount the
O3 Pure LS to wall studs, you should use the "molly" type expandable screw anchors.
For any other type of mounting scenario (concrete block, etc.) please consult your
local hardware store for assistance.
If needed remove the cover from your O3 Pure LS by pressing the tabs on each side
of the cover inwards. (Fig. d - d.1) While holding the tabs in, lift the cover up 1 inch
(2.54 centimeters) and then straight out toward you. There is a quick
disconnect for the Ozone Level Button. It is located behind the cover and can be
used to set the cover down for easier installation.
Place the O3 Pure LS against the wall so that the protruding screws slip through the
"keyholes" (Fig. e - e.1) in the back of the unit. Gently slide the unit down into the lock
position of the keyholes. You can now tighten the two screws to hold the unit firmly in
place. DO NOT over tighten the screws.
Turn off the hot and cold water taps/faucets to your washing machine. Place a pail
under the cold water hose connection to the washing machine. Disconnect the cold
hose from the washing machine placing the end into the pail. Flush cold water line with
½ gallon (2 litres) of water by turning the cold water tap on. Check filter (if applicable)
at the cold water inlet of washing machine. Clean residue from filter if necessary.
Check that the rubber washer in the hose is in place and con-nect the cold water
hose from the cold water supply to the inlet supply of the O3 Pure LS (Fig. f - f.2).
Properly tighten the hose to the inlet fitting, but do not over tighten.
Using the new hose provided connect one end of the hose to the water outlet of the
O3 Pure LS and the other end of the hose to the cold water inlet of the
washing
machine
(Fig. f
Properly
tighten
both
ends
of
the
hose,
-
f.1)
but do not over tighten.
Replace the cover on the O3 Pure LS.
Plug the power adapter into the DC adapter plug-in on the side of the O3 Pure LS unit
(d.2) and then plug the adopter into the wall outlet. (Fig. b)
Ensure all hoses are properly installed and tightened, and that the power supply has
been securely plugged in. SLOWLY turn the COLD water supply back on and
check for any leaks or drips. Gently retighten the fittings and if leaks are
apparent, be careful not to over tighten.