MC-LTE-Gateway Mobile Programmable Gateway This documentation applies to MC-LTE-GATEWAY SW version 1.1.1 and later. 1 GENERAL ..............................4 ..........................4 ARRANTY PROVISIONS 2 SAFETY ................................. 4 ........................4 ECHNICAL LIMITING VALUES ........................4 BLIGATIONS OF THE OPERATOR ........................4 UALIFICATION OF PERSONNEL ....................
Page 3
ROUBLESHOOTING 12.3 ..............................29 EPAIR 13 DISPOSAL..............................29 13.1 ........................ 29 ETURN OF THE OLD EQUIPMENT MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
Separate the packaging components made of cardboard and paper as well as plastic and recycle them using the appropriate collection systems. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
MC-LTE-GATEWAY web interface under System -> Software -> Installed. 4 Contents The package includes the accessories listed below. Please check that all accessories listed are included in your box. If a part is missing or damaged, please contact MC Technologies directly. • MC LH Gateway •...
MC-LTE-Gateway Mobile Programmable Gateway 5 Technical specifications The following specifications apply to all versions of the MC-LTE-GATEWAY. If these variants differ from one another, the different values are indicated separately. Technical Data Physical properties Physical characteristics Value Supply Voltage 8 V ... 30 V DC...
1. Login to Luci web interface using your device IP address (default: 192.168.2.1) 2. On the main page, scroll down to MC info Tab 3. Under Modem Revision, you can read the firmware version of your MC-LTE-GATEWAY Model Chip. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany...
MC-LTE-Gateway Mobile Programmable Gateway 7 Ports and display The following figures show a maximum equipped version of the MC-LTE-GATEWAY. Depending on the variant, your MC-LTE-GATEWAY may not have all connections, display or control elements. 7.1 Power supply and serial interface The connection is made via a 6-pin connector socket "Molex 43045-0614".
SIM card holder is unlocked by sliding the holder to the left. 8.2 Power supply The MC-LTE-GATEWAY is operated with a supply voltage of 10 - 30V DC. Please connect an external DC power supply with an output voltage of 10 - 30V (e.g. 12V > 1.2A or 24V >...
Mobile Programmable Gateway Confirm your entries by clicking on the "SAVE & APPLY" button. Please disconnect the MC-LTE-GATEWAY briefly from the power supply. After a startup phase of several minutes, log in to the web interface again. Navigate to the menu item "Network"...
1. Connect your MC-LTE-GATEWAY using Serial adapter to your PC. 2. On your PC, open the device manager to check the COM port of your MC-LTE-GATEWAY (If there are multiple COM ports, try disconnecting and reconnecting the Serial adapter to detect the right port).
1. Type: ssh root@192.168.2.1 2. Type the password. 3. Open the configuration file using command: vi /etc/config/network MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
Page 16
4. Press “i” to enter the input mode, and change the line "option ipaddr" in the interface "lan" to the corresponding address. 5. If the MC-LTE-GATEWAY is to go online via a router, the line option gateway 'aaa.bbb.ccc.ddd' can be added (with the IP address of the gateway).
Click on SAVE&APPLY. Login in to LuCi using the new IP address within the given 30 seconds. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
Select the node you want to add from the nodes list (i.e. Inject node, allow injecting messages into a flow). Drag it into the workspace. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
Deploy Now click on the Deploy button to deploy the flow to the server. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
This section is only for MC-LTE-GATEWAY devices that support wireless connection (Wifi). MC-LTE-GATEWAY in Access Point mode MC-LTE-GATEWAY can be used as an access point for other devices to wirelessly connect to it. To set MC-LTE-GATEWAY in Access point mode: 1.
MC-LTE-Gateway Mobile Programmable Gateway MC-LTE-GATEWAY as Wifi Client MC-LTE-GATEWAY can be used as a Wifi client and connect to access point in its range. To set MC-LTE-GATEWAY in Clinet mode: 1. In LuCI, click on Network then on Wireless. 2. Under Wireless Overview, click on SCAN.
9.3 LED Warn (Red) This LED is Programmable. To configure the LEDs, you need to log in to the MC-LTE-GATEWAY using LuCI web interface. Click on "System" in the left menu and then on "LED Configuration". Click on the "ADD LED ACTION" button.
LED Configuration can be done same as for LED warn (Red). LED Name LED 1 MC-LTE-Gateway:orange:info LED 2 MC-LTE-Gateway:orange:status MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
• Client certificate (client.crt) and client key (client.key) 10.1 Client Configuration 1. After logging to MC-LTE-GATEWAY Luci interface using the IP address (default 192.168.2.1), click on “OpenVPN” under “VPN” tab. 2. Click on “EDIT” at “sample_client” tab. 3. Click on “Switch to advanced configuration”.
Page 25
5. Click on “SAVE & APPLY” and then “BACK TO OVERVIEW”. 6. Enable the configured instance, then click on “SAVE AND APPLY”, then “START”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
MC-LTE-Gateway Mobile Programmable Gateway 10.2 Server Configuration 1. After logging to MC-LTE-GATEWAY Luci interface using the IP address (default 192.168.2.1), click on “OpenVPN” under “VPN” tab. 2. Click on “EDIT” at “sample_server” tab. 3. Click on “Switch to advanced configuration”.
Page 27
5. Click on “SAVE & APPLY” and then “BACK TO OVERVIEW”. 6. Enable the configured instance, and then click on “SAVE AND APPLY”, then “START”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
4. Set wanted “Port” and type of “Protocol”. 5. Type wanted device (/dev/ttymcx3 for Serial port RS232). 6. Click on “SAVE” then “SAVE&APPLY”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
13 Disposal 13.1 Return of the old equipment In accordance with WEEE regulations, the return and recycling of old MC Technologies equipment for our customers is regulated as follows: Please send your old devices carriage paid to the following address:...