MC Technologies MC100 User Manual

MC Technologies MC100 User Manual

Terminal / gateway
Hide thumbs Also See for MC100:
Table of Contents

Advertisement

Quick Links

MC100
Mobile programmable gateway
MC100 Terminal / Gateway
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
User Manual
MC100 GPIO
MC100 SensT2
MC100 WMBUS
MC100 SensorBox
Version v2.0.2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MC Technologies MC100

  • Page 1 User Manual MC100 Terminal / Gateway MC100 GPIO MC100 SensT2 MC100 WMBUS MC100 SensorBox Version v2.0.2 MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 2: Table Of Contents

    ................... 21 NSTALLATION OF TO A MOTOR VEHICLE NODE-RED WEB INTERFACE ........................22 Enable the Node-Red installed in MC100: ..................22 Install extra modules: ........................22 Add a node ............................22 Add a debug node ........................... 23 Wire the nodes ..........................23 Deploy .............................
  • Page 3 PT100 / PT1000 Inputs ........................40 AC Out Relais ........................... 40 AC IN Relais ............................. 41 ..............................42 12 SETTING UP WIFI ............................ 43 MC100 in Access Point mode ......................43 MC100 as Wifi Client ........................45 13 OPENVPN .............................. 46 ........................... 46 LIENT ONFIGURATION ..........................
  • Page 4 MC100 Mobile programmable gateway CI ......................56 ETTING MCWMBUS TOOL USING Enable the mcwmbus installed in MC100: ..................56 Setting WmBus ..........................56 ....................57 NSTALLING OMMAND LINE TOOL MCWMBUS ..........................57 ASIC FUNCTIONALITY ........................... 57 UTPUT FORMATS hex ..............................57 json ..............................
  • Page 5: General

    • The maximum input voltage and the maximum input current must not be exceeded. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 6: Obligations Of The Operator

    Separate the packaging components made of cardboard and paper as well as plastic and recycle them using the appropriate collection systems. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 7: Basic Safety Requirement

    MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 8: Liability Regulations

    Please contact our support department (support@mc-technologies.net) for a list of open source software used in this product. Alternatively, a list of the open source software used can be found in the MC100 web interface under System -> Software -> Installed. 4 Device variants This manual describes different variants of the MC100 terminal/gateway.
  • Page 9: Contents

    • 4G LTE MC100 WMBUS Gateway 5 Contents The package includes the accessories listed below. Please check that all accessories listed are included in your box. If a part is missing or damaged, please contact MC Technologies directly. • MC 100 Terminal / Gateway •...
  • Page 10 Mobile programmable gateway LED 4: Long-time Off: Searching for connection. Long-time ON: Connected. Flashing quickly: Packet Data transfer. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 11: Ports And Display

    MC100 Mobile programmable gateway 7 Ports and display The following figures show a maximum equipped version of the MC100. Depending on the variant, your MC100 may not have all connections, display or control elements. Port Description Power supply GPIO I/O-Interfaces...
  • Page 12 4 – 20mA LS 2 analog inputs 4 to 20mA Loop Current 1-Wire 1 one-wire or single-wire bus input MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 13 Output relay 1 220v Output relay AC power supply 85 to 264 V AC supply power MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 14: Installation

    Power supply The MC100 is operated with a supply voltage of 10 - 30V DC. Please connect an external DC power supply with an output voltage of 10 - 30V DC to the power supply socket "POW" (e.g.
  • Page 15: Establishing A Mobile Connection

    Confirm your entries by clicking on the "SAVE & APPLY" button. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 16: Online-Test

    Navigate to the menu item "Network" and "Diagnostics". Click on the "IPV4 PING" button under "Network Utilities". The selected server on the Internet should answer with PING times. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 17: Check Modem Version

    1. Login to Luci web interface using your device IP address (default: 192.168.2.1) 2. On the main page, scroll down to MC info Tab Under Modem Revision, you can read the firmware version of your MC100 Model Chip. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany...
  • Page 18: Internet Access

    (e.g. www.mc-technologies.net). Access via SSH To access the Linux system of the MC100, you must connect to the same IP address (default: 192.168.2.1) as the web interface with an SSH client. Most Linux distributions already have an SSH client installed.
  • Page 19: Using Luci Web Interface

    2. Change the line "option ipaddr" in the interface "lan" to the corresponding address. 3. If the MC100 is to go online via a router, the line option gateway 'aaa.bbb.ccc.ddd' can be added (with the IP address of the router).
  • Page 20 5. Login in to LuCi using the new IP address within the given 90 seconds to save the new settings. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 21: Installation Of Mc100 To A Motor Vehicle

    There are variants of the MC100 (general purpose) which do not contain the E1 type approval marking. The installation of the MC100 in a motor vehicle itself, its additional devices such as cables and antennas as well as the connection to the vehicle electronics must be carried out by a qualified vehicle workshop or a specialist workshop.
  • Page 22: Node-Red Web Interface

    Select the node you want to add from the nodes list (i.e. Inject node, allow injecting messages into a flow). Drag it into the workspace. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 23: Add A Debug Node

    Deploy Now click on the Deploy button to deploy the flow to the server. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 24: Readout Analog And Digital Io's Via Node-Red Website Interface

    Digital Inputs 1. Add the inject node. 2. Add the digital inputs node. 3. Double click on MC100 GPIO digital input node to open the settings menu and choose a Digital input. 4. Add Debug node (change name if wanted).
  • Page 25: Dashboard

    4. Double click on the nodes to change their Properties as wanted. 5. In a new tab open http://localhost:1880/ui (e.i. http://192.168.2.1:1880/ui) MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 26: Mc100 Senst2

    PT100/1000 1. Add the Inject node 2. Add MC100 SensT2 RTD 3. Double click on MC100 SensT2 RTD node to open the settings menu and choose RTD and Output type. 4. Add Debug node (Change name if wanted) 5. Wire and Deploy MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website &...
  • Page 27: Control And Readout Of Analog And Digital Io's And Leds Via Command Line Interface

    11 Control and readout of analog and digital IO's and LEDs via command line interface The digital and analog inputs and outputs of the MC100 products can be controlled or read out by commands via command line interface using SSH access or from programming tools.
  • Page 28: Ethernet-Interface (All)

    DC voltage must be between 8 and 30V. Port Description POW - Power supply, negative connection POW + Power supply, positive connection MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 29: Mc100 Gateway

    Reading Input I1 Command: cat /sys/class/gpio/mc100:in1/value Response: 1# or. 0# Digital Outputs The MC100 Gateway has two digital outputs. The outputs are solid state relays and switch against IGND. Function: Switching the digital outputs O1 and O2 Port Parameter Read...
  • Page 30: Rs485 Interface 2-Wire Bus Without Galvanic Isolation

    Request to Send Clear to Send Not connected Note: A hardware handshake is, using RS232 interface, not possible. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 31: Usb-Port 2.0 Type A

    Function: Reading the digital inputs I1 to I8 Port Parameter Read Write Path /sys/gpio_board/input/1 /sys/gpio_board/input/2 /sys/gpio_board/input/3 /sys/gpio_board/input/4 /sys/gpio_board/input/5 /sys/gpio_board/input/6 /sys/gpio_board/input/7 /sys/gpio_board/input/8 MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 32: Digital Outputs

    The input current at 10V is approx. 2 mA Note: The applied DC voltage must not exceed 10V. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 33: Current Inputs 0 - 20Ma

    Converting to mA Formula: Current in mA = Value / 200 Example: Value = 2000 corresponds to 10mA MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 34: Pwm

    /sys/gpio_board/pwm/prescalar Pulse {0,65535} /sys/gpio_board/pwm/1 Prescaler {0,1023} /sys/gpio_board/pwm/prescalar Pulse {0,65535} /sys/gpio_board/pwm/2 Period*{0,65535} /sys/gpio_board/pwm/period *Only if MC100 GPIO board supports Period. MC100 SensT2 Digital Inputs Port Description DGND1 Digital Ground1, electrically isolated to all (D)GND I1 bis I4 Digital inputs Input voltage: 0 to 30V Switching threshold: approx.
  • Page 35: Digital Outputs

    Positive connection Input 1 Negative connection Input 1 Positive connection Input 2 Negative connection Input 2 MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 36: Current Inputs 0 - 20Ma

    It is possible both to supply the sensor with power and to measure the current it draws over the same two wires. The sensor will be powered from the MC100 SensT2. A voltage is applied to the terminals +A3 or +A4 for this purpose. Connect the sensor to +A3 and A3 or +A4 and -A4.
  • Page 37: Current Outputs 0 - 20Ma

    Value = 112000 corresponds to +30,84°Celsius Value = 100000 corresponds to 0°Celsius Value = 90000 corresponds to -25,5°Celsius MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 38: Mc100 Sensorbox

    Switch on output ISO OUT1 Command: echo 1 > /sys/sensor_carrier_board/outputs/output1/value Response: Example: Value = 6400 corresponds to 6.4V MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 39: Current Input 0 - 20Ma Rx / Iso

    It is possible both to supply the sensor with power and to measure the current it draws over the same two wires. The sensor will be powered from the MC100 SensorBox. A voltage is applied to the terminals + and – of 4-20 mA ISO for this purpose. Connect the sensor to + and –...
  • Page 40: Pt100 / Pt1000 Inputs

    AC Out Relais NC COM NO Port Description Normally Close to COM Switch Normally Open to COM MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 41: Ac In Relais

    Read Write Path AC IN /sys/sensor_carrier_board/ac/acin/value Example: Read out AC input status Command: cat /sys/sensor_carrier_board/ac/acin/value Response: MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 42: Leds

    Green, Configurable. Default: Blinking: Booting ON: Device is ready to be used. MC100 has three LEDs that can be configured: info, status and warn. To configure the LEDS: 1. Login to MC100 web interface. 2. Click on System -> LED Configuration.
  • Page 43: Setting Up Wifi

    This section is only for MC100 devices that support wireless connection (Wifi). MC100 in Access Point mode MC100 can be used as an access point for other devices to wirelessly connect to it. To set MC100 in Access point mode: 1.
  • Page 44 8. If needed, configure further settings according to your needs. Other default settings ordinarily correct for general usage. 9. Click on SAVE, then SAVE&APPLY MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 45: Mc100 As Wifi Client

    MC100 Mobile programmable gateway MC100 as Wifi Client MC100 can be used as a Wifi client and connect to access point in its range. To set MC100 in Clinet mode: 1. In LuCI, click on Network then on Wireless. 2. Under Wireless Overview, click on SCAN.
  • Page 46: Openvpn

    • Server certificate (server.crt) and server key (server.key) • Client certificate (client.crt) and client key (client.key) Client Configuration 1. After logging to MC100 Luci interface using the IP address (default 192.168.2.1), click on „OpenVPN“ under „VPN“ tab. 2. Click on „EDIT“ at „sample_client“ tab.
  • Page 47 5. Click on „SAVE & APPLY“ and then „BACK TO OVERVIEW“. Enable the configured instance, then click on „SAVE AND APPLY“, then „START“. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 48: Server Configuration

    MC100 Mobile programmable gateway Server Configuration 1. After logging to MC100 Luci interface using the IP address (default 192.168.2.1), click on “OpenVPN” under “VPN” tab. 2. Click on “EDIT” at “sample_server” tab. 3. Click on “Switch to advanced configuration”. Edit the settings as the one in the server.conf file you have.
  • Page 49 5. Click on “SAVE & APPLY” and then “BACK TO OVERVIEW”. Enable the configured instance, and then click on “SAVE AND APPLY”, then “START”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 50: Ser2Net

    5. Type wanted device (ex. /dev/ttymcx0 for Serial port RS232). 6. Click on “SAVE” then “SAVE&APPLY”. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 51: Firewall

    Masquerading: Allows one or more devices in a zones network without assigned IP addresses to communicate with the Internet. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 52 Restrict to address family option defines to what IP families the zone belongs to IPv4, IPv6 or both. Restrict masquerading to given source/destination subnets defines one or more MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 53: Port Forwards

    Internal port: Redirect matched incoming traffic to the given port on the internal host. The user can add, edit or delete port forwarding rules. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 54: Traffic Rules

    The user can add, edit or delete source NAT rules. For every rule can be defined these options: MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 55: Custom Rules

    The commands are executed after each firewall restart, right after the default ruleset has been loaded. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 56: Wmbus

    MC100 Mobile programmable gateway 16 WMBus General information The MC100 Terminal/Gateway can be extended with an extension board for Wireless M- Bus packages. Setting mcwmbus tool using LuCI Enable the mcwmbus installed in MC100: Click on "System" in the left menu and then on "Startup". Search for Initscript: “mcwmbus”...
  • Page 57: Installing Command Line Tool Mcwmbus

    Json interprets the message and gives as much information as possible. It also contains the raw message as a hexadecimal string. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 58 "VIF": 102, "VIFE": 0, "Unit": "External temperature (1e-1 deg C)", "Value": "233", "Timestamp": "2020-06-09T07:51:08Z" "RawMessage": "1644AF4C02000041011B7A980000000266E8000266E900" MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 59: Xml

    Or it can be used in combination with the integrated modem, to send messages to a server running in the cloud to have real time data available on your workstation. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 60: Writing On Disk

    To view live information in Node-RED, we can create a flow that has a rest-server and displays the information using the dashboard plugin for node-red. The output might look like this: MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 61 "33fa8aec.51c216","type":"comment","z":"2d7d91ec.eb8846","name":"README","info":"# WMBus message filter and display\n\nThis Flow is here to demonstrate how to work with WM-Bus messages received by the MC100.\n\nA command line tool will receive and parse the messages and post them to an url, which gets provided by node red. \n\nThis way every message can be parsed by node red.\n\nOn the command line call\n\n```\nmcwmbus -U json -u http://localhost:1880/wmbus\n```\n\nto start receiving messages.\n\nWe tent to provide an init script, that starts the command on boot, as well as node-red.\nIf this is not...
  • Page 62: Combine Data For 1H, 6H, 1Day And Send Via Ftp/Scp

    It will be helpful if you run the command that produced the error with “-vvvvvv” to turn on the maximal debug information. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 63: Modbus

    17 MODBUS Modbus messaging protocol is used to establish client-server (master-slave) communication between devices. MC100 can be used either as a master device (server) or slave device (client). MODBUS for Node-RED node-red-modbus is factory installed on MC100. Do not try to install the node-red-contrib-modbus package from within Node- RED.
  • Page 64 11. Make sure, that the Serial Type is RTU-BUFFERED and not RTU. 12. Deploy. By clicking on Debug, messages fetched from the device should be seen. MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 65: Modbus Master Command Line Tool

    MC100 Mobile programmable gateway Modbus Master Command line Tool MC100 can be used as master device to read/write data command for up to 247 slave devices. Installation To install the modbus command line tool you have to install the ‘mcmodbus.ipk’ from the MC-Technologies update server.
  • Page 66: Modbus Slave Command Line Tool

    MC100 ModBus addressing map: Example: The address of Digital Input 4 on MC100 GPIO is: 1204 MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 67: Json Configuration File

    MC100 Mobile programmable gateway The address of RTD 2 on MC100 SensT2 is: {6104,6105} Json Configuration file Example: "type": "file", "address": 4000, "num_addresses": "register": true, "output": true, "filename": " /sys/sensor_carrier_board/adcoutputs/adcoutput/value", "factor": 1000, "isfloat": true, "MinValue": 4000, "MaxValue": 20000 Modbus data is most often read and written as "registers" which are 16-bit pieces of data.
  • Page 68: Mbus

    The MC100 terminal/gateway can be used with an additional module to receive M-Bus packets from various sensors (heat cost allocators, electricity meters ...). Setting up the MBUS module The internal module for M-Bus is connected to a serial interface of the MC100. Communication specifications Technological feature...
  • Page 69: 19 1-Wire

    2. Check Enabled check-box 3. Mountpoint can be changed as wanted, default is /mnt/owfs 4. SAVE&APPLY MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 70: Owhttpd

    You can reach the owhttpd web interface with the same IP address as the standard web interface and the specification of the port (e.g. 3001). Example with default address: http://192.168.2.1:3001 MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net...
  • Page 71: Factory Reset

    All customized setting will be reset to factory. Make sure you are directly connected to the MC100. To reset the MC100: • Locate the Reset button on the back of your MC100 device. • Use the pointed end of a paperclip or similar object to press and hold the Reset button.
  • Page 72: Maintenance, Repair And Troubleshooting

    It is not permitted to open the product for repair work or modifications. 22 Disposal Return of the old equipment In accordance with WEEE regulations, the return and recycling of old MC Technologies equipment for our customers is regulated as follows: Please send your old devices carriage paid to the following address:...

This manual is also suitable for:

Mc100 gpioMc100 senst2Mc100 wmbusMc100 sensorbox