Summary of Contents for Giacomini KFC-WD

  • Page 1 KFC-WD Installation manual  10/2023 Installation manual Fan coil for wall down installation Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italy  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 2 Overall dimensions KFC-WD ........
  • Page 3 Avoid prolonged contact with the direct air flow. After unpacking, make sure that all the components are Product range present. If not, contact the Giacomini agent who sold Do not leave the room closed for long periods. the appliance to you.
  • Page 4 Giacomini shall not respond for any damage to persons, Vertical floor or wall installation Only the images are to be considered as a mirror image.
  • Page 5 INSTALLATION INSTALLATION Mounting front grill safety support Air intake grill fixing In the case in which the cooler-convector is installed in a Separate the two clamps; To prevent the grille from being accidentally removed or So it it takes just fix the screws in dedicated holes located horizontal position, to guarantee the safety of the cleaning/ open the front grill and completely unscrew the fixing left loosened by the quick-release pads preventing the fan...
  • Page 6 INSTALLATION INSTALLATION Hydraulic connections 2.10 Filling the system U.M. 1000 When starting up the system, make sure that the hydraulic thermo-valve has already been powered use the special unit lockshield is open. If there is no electric power and the cap to press the valve stopper to open it.
  • Page 7 When necessary, clean the outer surfaces of the KFC-WD Wait until the parts have cooled down to avoid the risk cooler-convector with a soft cloth damp cloth.
  • Page 8 INSTALLATION INSTALLATION For the versions with a mobile panel, rest it in its Cleaning filtering seats position, parallel to the front panel and press until it is suck up the dust with a vacuum cleaner It is forbidden to use the unit without the net filters. blocked.
  • Page 9: Troubleshooting

    The appliance makes an excessive noise. an authorised service centre or an authorised qualified There are formations of dew on the front panel. person, but do not intervene personally. Technical specifications KFC-WD - 2 TUBI Version u.m. u.m. 1000 Table of anomalies and remedies COOLING PERFORMANCES (W 7/12 °C;...
  • Page 10 TROUBLESHOOTING NOTE KFC-WD - 2 TUBI Version u.m. u.m. 1000 Maximum sound power level 51,00 53,00 54,00 55,00 57,00 dB(A) Sound pressure level at maxi- 41,0 42,0 44,0 46,0 47,0 dB(A) mum air flow Sound pressure level at me- 33,0...
  • Page 11 The crossed-out wheeled dustbin symbol, on the label on the product, indicates the compliance of this product with the regulations regarding Waste Electrical and Electronic Equipment. Abandonment in the environment or illegal disposal of the product is punishable by law.  Additional information. For more information, go to giacomini.com or contact our technical  Safety Warning. Installation, commissioning and periodical maintenance of the product assistance service.
  • Page 12 KFC-WD User manual  09/2023 User manual Fan coil for wall down installation Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italy  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 13 By following the suggestions contained in this manual, the product you have purchased will operate without problems, giving you optimum room temperatures with minimum energy costs. Giacomini S.p.A. Compliance This unit complies with the following European Directives: •...
  • Page 14 General table of contents GENERALITES  Mises en garde générales  ............4 Règles fondamentales de sécurité ...
  • Page 15: Fundamental Safety Rules

    GENERAL General waenings This instruction is an integral part of the booklet of the It is forbidden to modify the safety or adjustment appliance on which the kit is installed. Please consult devices without authorisation from and indications of the this booklet for general warnings and fundamental safety manufacturer.
  • Page 16: Key Function

    Display KFCDBxxx SMART TOUCH electronic control panel with device side continuous modulation These controls make room temperature adjustment (with After 20 seconds from the last action the panel offset settable from the keyboard) completely autonomous brightness will be reduced for improved night-time through the AUTO, SILENT, NIGHT and MAX programmes comfort, and the room temperature will appear on the by means of a probe located in the lower part of the device,...
  • Page 17: Temperature Selection

    General On Switch In order to manage the device via the control panel, this also be switched on. must be connected to the mains electricity. - Turn the device on by activating the general switch If a general switch is installed on the power line, this must Activation To activate the device Operation...
  • Page 18 Automatic operation Operation Display Press and hold the AUTO key. The function being activated is indicated by the relevant symbol appearing on the display. Ventilation speed adjustment is carried out automatically point, according to a PI-type algorithm. between the minimum and maximum values, according to the distance of the actual room temperature from the set 2.10 Silent operation...
  • Page 19: Room Temperature Probe Regulation Offset

    2.15 Deactivation Operation Display Press and hold the ON Stand-By key for approx. 2 seconds. No illuminated signals on the display at all means that the system is in stand-by (no operation). The controller also ensures anti freezing when in stand-by. 2.16 Room temperature probe regulation offset As the detection probe is towards the bottom of the...
  • Page 20: Maintenance

    MAINTENANCE External cleaning Disconnect the unit from the power supply before Do not use abrasive sponges or abrasive or corrosive each cleaning and maintenance intervention by setting detergents as you might damage the painted surfaces. the main power supply switch to off. When necessary, clean the external surfaces of the fan Wait for the components to cool down in order to coil with a soft damp cloth.
  • Page 21 Removal of filtering cells in versions with mobile panel suction. Pass hand underneath the far side of the mobile panel Lift and extract the mobile panel Press the plastic tabs Extract the filter. Mobile panel Filter Plastic tabs Filter extraction Cleaning the filters Remove dust from the filter with a vacuum cleaner Do not use the device without the mesh filter.
  • Page 22: Suggestions For Power Saving

    Complete cleaning operations For versions with a flap grill, insert the two tabs in the corresponding loops, rotate and attach with a light tap to the upper section. Tabs Loops For versions with a mobile panel, rest in position parallel to the front and press until locked into place. Suggestions for power saving Ensure filters are constantly clean;...
  • Page 23: Troubleshooting Table

    TROUBLESHOOTING Troubleshooting Ventilation does not start even if there is hot or cold In the event of water leaks or anomalous operation, water in the hydraulic circuit. disconnect mains power immediately and close all The device leaks water when heating. water taps.
  • Page 27 The crossed-out wheeled dustbin symbol, on the label on the product, indicates the compliance of this product with the regulations regarding Waste Electrical and Electronic Equipment. Abandonment in the environment or illegal disposal of the product is punishable by law.  Additional information. For more information, go to giacomini.com or contact our technical  Safety Warning. Installation, commissioning and periodical maintenance of the product assistance service.