DAAB DB409 INSTRUCTION MANUAL FOR
THE VFD-EL FREQUENCY CONVERTER
For the DAAB EP104 automatic control
system Version 4.07
FAAC Nordic AB
BOX 125, SE-284 22 PERSTORP SWEDEN,
+46 435 77 95 00,
support@faac.se
www.faac.se

Advertisement

loading

Summary of Contents for DAAB FAAC DB409

  • Page 1 DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER For the DAAB EP104 automatic control system Version 4.07 FAAC Nordic AB   BOX 125, SE-284 22 PERSTORP SWEDEN, +46 435 77 95 00, support@faac.se www.faac.se...
  • Page 2: Installation

    DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL Installation 1. Disconnect the power to the EP104 2. Screw the DB409 card into place on the spacers on the EP104 using two M3x5 screws. Connection The frequency converter being connected to the DB409 must be a DELTA VFD-EL. This frequency converter is based on negative logic.
  • Page 3 DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL • Wiring diagram for one motor A Mains power B Control panel C NPN/PNP D AVI/ACI E Control terminals F RS485 (RJ-45) G Motor terminals Important: Before connection takes place, the following cables must be changed:...
  • Page 4 DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL • Circuit diagram for two motors A Mains power B Control panel C NPN/PNP D AVI/ACI E Control terminals F RS485 (RJ-45) G Motor terminals Important: Before connection takes place, the following cables must be removed:...
  • Page 5: Factory Setting

    • Modification of the motor winder The following criteria must be met in order to use the DAAB motor winder with the frequency converter: • If mechanical limit switches are used, the limit switch cams must be wider than normal.
  • Page 6 DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL • Channel settings in the EP104 when using an encoder, DB405 For the EP104 to measure current and power correctly, C202 must be set to 4, frequency converter. When a frequency converter is used with the EP104, load guard with personal protection cannot be used. For this reason, make the following channel settings in the automatic control unit: C230 = 0.00 - This parameter disables the personal protection for motor 1.
  • Page 7 DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL accordance with F008 and F009. This calculated angle depends on speed, slow speed, retardation and chosen ratio. The angles in these channels are calculated continuously on the basis of these parameters. If stopping at the specified angle for open or closed position takes place too abruptly, there is a possibility of adding a certain angle to the values in these channels.
  • Page 8 DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL • Channel list, Frequency converter, F-channels Name Range Factory Setting Ref. page F001 Communication with frequency converter 0 - 1 Communication disabled Communication activated F002 Acceleration time from closed position 0.5-9.9 seconds 1.0 sec...
  • Page 9 DAAB INTERFACE BOARD DB409 INSTRUCTION MANUAL F030 Choice of ratio for motor 1 0 - 7 <?> Not selected, in this position the motor only rotates at 25Hz MK with pulleys 40/71 (ratio 1318:1) MK with pulleys 50/71 (ratio 1098:1)