Evident Vanta iX Series Installation Manual

X-ray fluorescence analyzer
Table of Contents

Advertisement

Vanta iX Family
X-Ray Fluorescence Analyzer
Installation Guide
This instruction manual contains essential information on how to use this Evident product safely and effectively.
Before using this product, thoroughly review this instruction manual. Use the product as instructed.
Keep this instruction manual in a safe, accessible location.
10-019116-01EN — Rev. 4
September 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vanta iX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Evident Vanta iX Series

  • Page 1 10-019116-01EN — Rev. 4 September 2022 This instruction manual contains essential information on how to use this Evident product safely and effectively. Before using this product, thoroughly review this instruction manual. Use the product as instructed. Keep this instruction manual in a safe, accessible location.
  • Page 2 Evident Scientific Inc., 48 Woerd Avenue, Waltham, MA 02453, USA Copyright © 2022 by Evident. All rights reserved. No part of this publication may be reproduced, translated, or distributed without the express written permission of Evident. This document was prepared with particular attention to usage to ensure the accuracy of the information contained therein, and corresponds to the version of the product manufactured prior to the date appearing on the title page.
  • Page 3: Table Of Contents

    10-019116-01EN, Rev. 4, September 2022 Table of Contents List of Abbreviations ..................7 Important Information — Please Read Before Use ........9 Intended Use .......................... 9 Instruction Manual ........................ 9 Instrument Compatibility ....................10 Repair and Modification ..................... 10 Safety Symbols ........................10 Safety Signal Words ......................
  • Page 4 3.1.2 LED Connector and Cable Assembly ............46 3.1.3 Customer I/O Connector and Cable ............47 3.1.4 Evident I/O Connector and Cable ..............48 3.1.5 GPIO Breakout Board ..................48 Power Button ......................50 Status Lights ....................... 51 Mounting Instructions ....................51 4.
  • Page 5 10-019116-01EN, Rev. 4, September 2022 4.1.2 Measurement Window Removal ..............61 4.1.3 Measurement Window Replacement ............63 Troubleshooting ......................67 Appendix A: Specifications ................69 Appendix B: Radiation Profile ..............71 Profile Testing Information ..................72 Test Setup and Survey Locations ................72 Appendix C: Alloy Grade Libraries ..............
  • Page 6 10-019116-01EN, Rev. 4, September 2022 Table of Contents...
  • Page 7: List Of Abbreviations

    10-019116-01EN, Rev. 4, September 2022 List of Abbreviations ALARA as low as reasonably achievable EFUP environment-friendly use period GPIO general purpose input/output thermoluminescent dosimeter X-ray fluorescence List of Abbreviations...
  • Page 8 10-019116-01EN, Rev. 4, September 2022 List of Abbreviations...
  • Page 9: Important Information - Please Read Before Use

    10-019116-01EN, Rev. 4, September 2022 Important Information — Please Read Before Use Intended Use The Vanta iX in line X-ray fluorescence analyzer is an energy dispersive X-ray fluorescence spectrometer that provides customizable, continual measurements on any surface. Do not use the Vanta iX for any purpose other than its intended use. Instruction Manual This instruction manual contains essential information on how to use this product safely and effectively.
  • Page 10: Instrument Compatibility

    PC using an Ethernet connection. The unit derives its required DC input power from the AUX DC port or Power over Ethernet (PoE) port. CAUTION Always use equipment and accessories that meet Evident specifications. Using incompatible equipment could cause equipment malfunction and/or damage, or human injury.
  • Page 11: Safety Signal Words

    10-019116-01EN, Rev. 4, September 2022 General warning symbol This symbol is used to alert the user to potential hazards. All safety messages that follow this symbol shall be obeyed to avoid possible harm or material damage. Radiation warning symbol (International) Radiation warning symbol (Canada) Radiation warning symbol (China) These symbols are used to alert the user to the presence of potentially harmful...
  • Page 12: Note Signal Words

    10-019116-01EN, Rev. 4, September 2022 WARNING The WARNING signal word indicates a potentially hazardous situation. It calls attention to a procedure, practice, or the like that if not correctly performed or adhered to could result in death or serious personal injury. Do not proceed beyond a WARNING signal word until the indicated conditions are fully understood and met.
  • Page 13: Safety

    For any problem or question regarding this instrument, contact Evident or an authorized Evident representative. • Do not allow metallic or foreign objects to enter the device through connectors or any other openings.
  • Page 14: Equipment Disposal

    WARNING Electrical Warnings If an unauthorized electrical connections are made to power the instrument, Evident cannot guarantee the electrical safety of the equipment. Equipment Disposal CAUTION Instruments with a damaged X-ray tube must be returned to your local distributor or the manufacturer.
  • Page 15: Ce (European Community)

    10-019116-01EN, Rev. 4, September 2022 CE (European Community) This device complies with the requirements of directive 2014/30/EU concerning electromagnetic compatibility, directive 2014/35/EU concerning low voltage, and directive 2015/863 which amends 2011/65/EU concerning restriction of hazardous substances (RoHS). The CE marking indicates compliance with the above directives. UKCA (United Kingdom) This device complies with the requirements of the Electromagnetic Compatibility Regulations 2016, the Electrical Equipment (Safety)
  • Page 16 10-019116-01EN, Rev. 4, September 2022 The China RoHS mark indicates the product’s Environment- Friendly Use Period (EFUP). The EFUP is defined as the number of years for which listed controlled substances will not leak or chemically deteriorate while in the product. The EFUP for the Vanta iX has been determined to be 15 years.
  • Page 17: Korea Communications Commission (Kcc)

    10-019116-01EN, Rev. 4, September 2022 Korea Communications Commission (KCC) 이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기 기로서 가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니 다 . KC (South Korea Community) This device complies with the requirements of KN 61000-6-2 and KN 61000-6-4 concerning electromagnetic compatibility.
  • Page 18: Ices-001 (Canada) Compliance

    (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Responsible party name: EVIDENT SCIENTIFIC INC. Address: 48 Woerd Avenue, Waltham, MA 02453, USA Phone number: +1 781-419-3900 ICES-001 (Canada) Compliance This Class A digital apparatus complies with Canadian ICES-001.
  • Page 19: Code De La Santé Publique (France)

    If the Vanta iX is not returned in its transport case, it could be damaged during shipping. Evident reserves the right to void the warranty on instruments damaged while in transit if they are shipped without their transport case. Prior to returning any units, contact Customer Service to obtain the required RMA number(s) and any important shipping information.
  • Page 20: Warranty Information

    Evident has no responsibility to provide any source code except the source code for certain software. https://www.olympus-ims.com/support/vanta-open-source-software-download/ Evident does not respond to any inquiries related to any of the source codes obtained at the above URL. Warranty Information...
  • Page 21: Technical Support

    After-Sales Service. To locate the nearest service center, visit the Service Centers page on the Evident Scientific Web site. Important Information — Please Read Before Use...
  • Page 22 10-019116-01EN, Rev. 4, September 2022 Important Information — Please Read Before Use...
  • Page 23: Introduction

    10-019116-01EN, Rev. 4, September 2022 Introduction The Vanta iX X-ray fluorescence (XRF) analyzer is a energy dispersive X-ray fluorescence spectrometer that provides customizable, sequential measurements on any surface. In an automated factory or processing plant, the system provides accurate chemical analysis for quality control applications. Main Applications The Vanta iX XRF analyzer delivers fast and precise identification and analysis of elements from magnesium to uranium (Mg to U), depending on the selected model...
  • Page 24 10-019116-01EN, Rev. 4, September 2022 Table 1 Analyzer features (continued) Feature Vanta iX C series Vanta iX M series Detector Large area performance IP54 IP54 IP rating Heat rating − − 10 °C to +50 °C 10 °C to +50 °C ...
  • Page 25: Safety Information

    The Vanta iX XRF analyzer is a secure and dependable instrument when used according to Evident recommended testing techniques and safety procedures. However, the Vanta iX produces ionizing radiation, and as such, it should only be used by individuals trained in correct operating techniques and authorized to use X- ray producing devices.
  • Page 26: Radiation Safety Program

    WARNING The X-ray tube in the Vanta iX XRF analyzer can emit ionizing radiation. Prolonged exposure can cause serious illness or injury. It is the responsibility of Evident customers to follow the operating instructions and safety recommendations in this manual and good radiation control practices.
  • Page 27: Safety Features

    The LED is a failsafe measure, and if the LED fails no X-rays will be emitted. Before X- rays can be emitted, the Evident-provided X-ray warning LED must be attached and functioning. Connect the LED cable before the device is powered up, if the cable is not detected at power-up no x-rays will be emitted even if the cable is later connected.
  • Page 28: General Precautions

    Post a sign near the Vanta iX indicating that it must only be used by operators who have completed a training course provided by your company, or who have attended an Evident training course and comply with any other requirements stipulated by local regulatory authorities.
  • Page 29: Service Considerations

    IMPORTANT Any required servicing must be performed by Evident or one of its authorized service representatives. Failure to observe this condition could result in voiding of the warranty. The...
  • Page 30: Power Cables And Cords

    10-019116-01EN, Rev. 4, September 2022 Power Cables and Cords The Vanta iX XRF analyzer is delivered standard with one AC power adaptor, one DC power cable, and one Ethernet cable. The AC power adaptor cable has a standard IEC 3 conductor power cord that includes a safety grounding plug.
  • Page 31: Power Indicator

    10-019116-01EN, Rev. 4, September 2022 1.9.1 Power Indicator The power button ( ) is back lit, so it also serves as the power indicator. NOTE The power button will begin flashing when power is initially provided to indicate power is present. 1.9.2 Radiation Being Emitted A failsafe radiation LED is connected to the LED port through the radiation LED cable...
  • Page 32: Radiation Safety Training Recommendations

    X-ray tubes. It is important to inform yourself about these rules. NOTE For the convenience of clients, Evident has compiled a list of recommendations. These recommendations: • Provide generic guidance on the ALARA (as low as reasonably achievable) approach to radiation safety.
  • Page 33: Dosimeters

    10-019116-01EN, Rev. 4, September 2022 CAUTION The system must be interlocked with an entry control system so that it cannot be operated if people are inside the restricted area near the X-ray beam. During operation, make sure that the Vanta iX remains under the direct control of a factory-trained, certified operator.
  • Page 34: Dosimeter Safety Program

    IMPORTANT Dosimeter badges are required in some countries or regions, and are optional in others. Evident recommends that all Vanta iX analyzer operators wear a dosimeter (badge or ring) for at least the first year of operating their analyzer(s). NOTE Every country (including each region, state, or province within a country) may have different regulations.
  • Page 35: Dosimeter Suppliers

    10-019116-01EN, Rev. 4, September 2022 The company receives the first lot of badges and distributes them to its analysts/operators. At the end of the interval: a) The company collects the badges and returns them to the service contractor for analysis. b) At the same time, the service contractor delivers another lot.
  • Page 36: Registration Requirements

    Table 3 Canadian Approved Dosimeter suppliers Company Location Telephone Mirion Dosimetry Irvine, CA 1-800-251-3331 Services Landauer Glenwood, Ilinois 1-708-755-7000 National Dosimetry Ottawa, Canada 1-800-261-6689 Services (Health Canada) 1.10.5 Registration Requirements Contact Evident for assistance with locating registration requirements. Chapter 1...
  • Page 37 10-019116-01EN, Rev. 4, September 2022 United States of America and Most Other Countries • Most states require some form of registration and generally require registration to be submitted within 30 days of receipt of the system. • Some states require advance notification. Canada •...
  • Page 38 10-019116-01EN, Rev. 4, September 2022 Authorized users List the analysts/operators who have been trained and authorized to operate the XRF equipment by the instrument owner and/or regulatory agency. Operating parameters of the Vanta iX XRF analyzer 8–50 kV; 5–200 µA max (depending on the model), 4 W maximum power output. Type of system Small industrial User training specification...
  • Page 39: Package Contents

    10-019116-01EN, Rev. 4, September 2022 2. Package Contents A complete Vanta iX package consists of an XRF analyzer and standard accessories. This chapter lists and describes the various components. Unpacking the Vanta iX Vanta iX XRF analyzers and accessories are shipped in a standard cardboard box with foam packing material.
  • Page 40: Optional Accessories

    DC power cable (P/N: 10-020010-00)   Ethernet cable (P/N: 10-013295-00)   Radiation LED assembly (P/N: 10-014685-00) (2) (2) Evident I/O cable (P/N: 10-013294-00)   GPIO breakout board (P/N: 10-021277-00)   Network port cap (P/N: 10-013297-00)  ...
  • Page 41: Analyzer Components

    10-019116-01EN, Rev. 4, September 2022 Analyzer Components Table 6 on page 41 lists the Vanta iX XRF analyzer’s components. Table 6 Components Component key Vanta iX XRF analyzer 1 Probe 2 Measurement window plate 3 Measurement window ⑤ 4 Latch ①...
  • Page 42 10-019116-01EN, Rev. 4, September 2022 Chapter 2...
  • Page 43: Installation

    XRF analyzer. Misuse of the Vanta iX could result in serious illness or injury. I/O Panel The I/O panel contains all of the Vanta iX I/O connectors (Figure 3-1 on page 44): DC power connector USB A connector Ethernet connector LED (radiation, light emitting diode) connector Customer I/O connector Evident I/O connector Installation...
  • Page 44: Power Connectors And Cables

    10-019116-01EN, Rev. 4, September 2022 ① ④ ② ⑤ ③ ⑥ Figure 3-1 I/O panel connectors 3.1.1 Power Connectors and Cables The power connectors enable you to connect DC power to the Vanta iX. IMPORTANT The Vanta iX requires a good electrical ground connection to the chassis to ensure safe and reliable operation.
  • Page 45: Figure 3-2 Dc Power Cable

    10-019116-01EN, Rev. 4, September 2022 The DC power connector (10–18 VDC) accepts a DC power cable to supply power to the instrument see Figure 3-2 on page 45. The 2 meter DC power cable comes with a barrel connector on one end to connect to the instrument, and a barrel connector on the other end to interface with the standard 18 VAC adapter (supplied).
  • Page 46: Led Connector And Cable Assembly

    PoE+. NOTE You can control the Vanta iX start/stop function through the Ethernet connection, or through the Evident I/O connector via discrete wiring by a PLC or similar type of controller. 3.1.2 LED Connector and Cable Assembly The LED connector enables you to use the radiation LED cable assembly to indicate when the X-ray tube is energized or radiation is being emitted.
  • Page 47: Customer I/O Connector And Cable

    GPIO board. The cable length is 2 meters. Figure 3-5 CUST I/O cable NOTE The customer I/O cable and Evident I/O cable are identical. However, the pinouts differ between the customer I/O connector and the Evident I/O connector. Installation...
  • Page 48: Evident I/O Connector And Cable

    (bare wire) for connection to the GPIO board. Figure 3-6 OLY I/O cable NOTE The Evident I/O cable and customer I/O cable are identical. However, the pinouts on the Evident I/O connector differ from the customer I/O connector. 3.1.5 GPIO Breakout Board The Vanta iX comes standard with one general purpose input/output (GPIO) breakout board (Figure 3-7 on page 49).
  • Page 49: Figure 3-7 Gpio Board

    The connectors on the top half of the breakout board are intended for the standard Evident I/O. The connectors on the bottom half of the breakout board are intended for customer configured I/O. The left and right sides are equivalent. Connect the Vanta iX to one side, and connect the other side to your interlocks, PLC, or other type of control system.
  • Page 50: Power Button

    10-019116-01EN, Rev. 4, September 2022 Power Button The power button manually turns on and off power to the Vanta iX after a power source (DC or PoE+) is connected to the instrument. To power on the XRF analyzer  Press and hold the flashing power button ( ) until the light stops flashing and becomes solid.
  • Page 51: Status Lights

    10-019116-01EN, Rev. 4, September 2022 NOTE At the end of the shutdown process, the LED cluster will be off, and the white power LED will be blinking. This indicates that the system is still powered but is not running. It is now safe to remove the DC or PoE+ power cables to power off the instrument.
  • Page 52 10-019116-01EN, Rev. 4, September 2022 • Compatibility information for selecting the correct screw type for the mounting holes All dimensions are in millimeters unless otherwise noted. Chapter 3...
  • Page 53: Figure 3-8 Vanta Ix Left Side

    10-019116-01EN, Rev. 4, September 2022 Figure 3-8 Vanta iX left side Installation...
  • Page 54: Figure 3-9 Vanta Ix Right Side

    10-019116-01EN, Rev. 4, September 2022 Figure 3-9 Vanta iX right side Chapter 3...
  • Page 55: Figure 3-10 Vanta Ix Top

    10-019116-01EN, Rev. 4, September 2022 Figure 3-10 Vanta iX top Installation...
  • Page 56: Figure 3-11 Vanta Ix Bottom

    10-019116-01EN, Rev. 4, September 2022 Figure 3-11 Vanta iX bottom Chapter 3...
  • Page 57: Figure 3-12 Vanta Ix Front

    10-019116-01EN, Rev. 4, September 2022 Figure 3-12 Vanta iX front Installation...
  • Page 58 10-019116-01EN, Rev. 4, September 2022 Chapter 3...
  • Page 59: Maintenance And Troubleshooting

    Immediately replace any broken or torn window. • For best results, regularly replace the window. • Make sure the replacement window matches your Vanta iX series and method. The correct window is required to achieve proper operation and accurate results. 4.1.1 Measurement Window Types Table 8 on page 60 describes the measurement window types.
  • Page 60: Table 8 Measurement Window Types

    10-019116-01EN, Rev. 4, September 2022 Table 8 Measurement window types Material Image Vanta iX series Part number Kapton 10-011890-00 mesh/reinforced prolene Prolene, 6 µm 10-015963-00 CAUTION To avoid damage to the analyzer, comply with the instructions below: • Do not touch or damage any internal components.
  • Page 61: Measurement Window Removal

    Turn off the Vanta iX. IMPORTANT Evident recommends that you remove the power source cable (PoE+ or DC) before removing the measurement window to be sure that the Vanta iX cannot be powered Locate the window faceplate latch at the front of the instrument (Figure 4-1 on page 61).
  • Page 62: Figure 4-2 Latch Pulled Out

    10-019116-01EN, Rev. 4, September 2022 Pull out the rear of the latch to release the tension on the faceplate (Figure 4-2 on page 62). Figure 4-2 Latch pulled out Pull out the front of the latch to fully open the faceplate latch (Figure 4-3 on page 62).
  • Page 63: Measurement Window Replacement

    10-019116-01EN, Rev. 4, September 2022 Alignment tab Figure 4-4 Faceplate alignment tab fully visible 4.1.3 Measurement Window Replacement The measurement window is attached by an adhesive to the back of the faceplate (Figure 4-5 on page 63). This procedure requires that you peel off the old window and place the new window.
  • Page 64: Figure 4-6 Peeling The Window (Left) And Pulling It Off (Right)

    10-019116-01EN, Rev. 4, September 2022 Figure 4-6 Peeling the window (left) and pulling it off (right) To replace the window Remove the window from its packaging and peel the backing material completely off the window (Figure 4-7 on page 64). IMPORTANT The back of the measurement window is coated with a sticky adhesive.
  • Page 65: Figure 4-8 New Window Aligned With Faceplate

    10-019116-01EN, Rev. 4, September 2022 Align and carefully press the window onto the faceplate (Figure 4-8 on page 65). IMPORTANT Handle the window by the edges to prevent contamination of the measurement area. Figure 4-8 New window aligned with faceplate Maintenance and Troubleshooting...
  • Page 66: Figure 4-9 Orienting Faceplate With Latch And Probe Cutout

    10-019116-01EN, Rev. 4, September 2022 Orient the faceplate with the latch and the cutout on the probe (Figure 4-9 on page 66). Probe cutout Latch Figure 4-9 Orienting faceplate with latch and probe cutout Slide the faceplate into the cutout on the probe, making sure the faceplate alignment tab is inserted into the tab slot (Figure 4-10 on page 66).
  • Page 67: Troubleshooting

    Vanta iX (Table 9 on page 68). If these measures do not restore the Vanta iX to full functionality, please contact Evident After-Sales Service. When contacting a service center, please provide the instrument model, serial number, current software version, and a brief description of your issue.
  • Page 68: Table 9 Troubleshooting Guide

    10-019116-01EN, Rev. 4, September 2022 Table 9 Troubleshooting guide Problem Possible solutions The Vanta iX does not turn Check the PoE+ or DC power connection to the Vanta iX. The analysis results do not • Test certified reference material. match with the expected •...
  • Page 69: Appendix A: Specifications

    Humidity: 10 % to 90 % relative humidity, noncondensing IP rating IP54 Operating system Linux Application software Evident proprietary data acquisition and processing package USB interface USB 2.0 type A host port for accessories such as USB flash drives Specifications...
  • Page 70: Table 11 Accessory Specifications

    RAD LED cable Includes an LED indicator (P/N: 10-014685-00) Customer I/O cable Connects bi-directional signals to the GPIO board (P/N: 10-013294-00) Evident I/O cable Connects bi-directional signals to the GPIO board (P/N: 10-013294-00) PoE+ network switch Supplies PoE+ (P/N: 10-021941-00)
  • Page 71: Appendix B: Radiation Profile

    10-019116-01EN, Rev. 4, September 2022 Appendix B: Radiation Profile The tables below represent upper bounds on the worst case maximum power and minimum beam filtration using a 316 stainless steel target. More specifically, the Vanta iX was operating at either 40 kV, 100 µA w/2 mm Al filter (model VIX-CW); or, 50 kV (model VIX-MR), 80 µA, 350 µm Cu filter.
  • Page 72: Profile Testing Information

    10-019116-01EN, Rev. 4, September 2022 Table 13 Maximum Leakage radiation measured at 50 kV in µSv/h Surveyed location Close 10 cm 30 cm Front 22.8 Left Side (front of scatter plane) 14.3 Right Side (front of scatter plane) Top (up to front cover seam) 27.6 Left Side (behind scatter plane) Right Side (behind scatter plane)
  • Page 73: Figure B-1 Test Setup And Survey Diagram

    10-019116-01EN, Rev. 4, September 2022 Top (up to front cover seam) Left side (behind scatter plane) Right side (behind scatter plane) Top (rear up to scatter plane) 10. Bottom (under the instrument) ① ⑤ ⑥ ③ ④ ② ② ⑨ ⑦...
  • Page 74 10-019116-01EN, Rev. 4, September 2022 Appendix B...
  • Page 75: Appendix C: Alloy Grade Libraries

    User library #2 • The Residuals (tramp) settings NOTE Libraries are editable. However, Evident does not recommend that users edit the Factory Grade library. Instead, copy the Factory Grade library to a user library, then make your edits. Residuals Settings Every Vanta iX XRF analyzer is shipped with Residuals (tramp) settings comprised of seven base alloys (Table 14 on page 76).
  • Page 76: Table 14 Residuals Settings Base Alloys

    10-019116-01EN, Rev. 4, September 2022 • Each sample is determined to be one of seven possible base alloys (Table 14 on page 76). • The analyzer applies the residual grade/base-specific residual limits from the matching residual grade. These residual or “alloy-base-specific” limits are applied when an element is detected in a specific grade.
  • Page 77: Factory Grade Library: M And C Series

    10-019116-01EN, Rev. 4, September 2022 Factory Grade Library: M and C Series Table 15 Cast aluminum alloys—M and C Series Table 16 Cobalt alloys—M and C Series AlnicoVIII Cobalt Elgiloy FSX-414 HS-1 HS-12 HS-188 HS-19 HS-21 HS-23 HS25-L605 HS-27 HS-3 HS-30 HS-31 HS-36...
  • Page 78: Table 17 Copper Alloys-M And C Series

    10-019116-01EN, Rev. 4, September 2022 Table 17 Copper alloys—M and C Series (continued) C 642 C 654 C 655 C 663 C 664 C 667 C 669 C 673 C 675 C 687 C 688 C 704 C 706 C 710 C 713 C 715 C 722...
  • Page 79: Table 19 Low-Alloy And Tool Steels-M And C Series

    10-019116-01EN, Rev. 4, September 2022 Table 18 Nickel alloys—M and C Series (continued) Monel411 MuMetal Nim101 PWA1480 PWA1484 Rene125 Rene142 Rene220 Rene77 Rene80 Rene95 Supertherm Udimet700 B 1900 B-1900 Hf C-1023 GMR235 Alloy D Duranickel Permanickel GH99 Table 19 Low-alloy and tool steels—M and C Series 1 1-4 Cr 2 1-4 Cr 5 Cr...
  • Page 80: Table 21 Titanium Alloys-M And C Series

    10-019116-01EN, Rev. 4, September 2022 Table 20 High-alloy and stainless steels—M and C Series (continued) Ni-hard#1 Ni-hard#4 Ni-Resist1 Ni-Resist2 Ni-Resist3 Ni-Resist4 Ni-Resist5 Ni-Span902 Nitronic32 Nitronic33 Nitronic40 Nitronic50 Nitronic60 RA85H ZeCor Zeron100 Table 21 Titanium alloys—M and C Series CP Ti Gr 1 CP Ti Gr 2 CP Ti Gr 4 CP Ti Gr 11...
  • Page 81: Table 23 Wrought Aluminum Alloys-M And C Series

    10-019116-01EN, Rev. 4, September 2022 Table 23 Wrought aluminum alloys—M and C Series (continued) 2024 2025 2030 2031 2034 2036 2090 2091 2094 2095 2097 2111 2117 2124 2195 2197 2214 2218 2219 2297 2519 2618 3002 3003 3004 3005 3009 3010 3011...
  • Page 82 10-019116-01EN, Rev. 4, September 2022 Appendix C...
  • Page 83: List Of Figures

    10-019116-01EN, Rev. 4, September 2022 List of Figures Figure 1-1 Dosimeters — Various styles ................34 Figure 3-1 I/O panel connectors ..................44 Figure 3-2 DC power cable ....................45 Figure 3-3 Ethernet (PoE+) cable ..................45 Figure 3-4 Radiation LED assembly .................. 46 Figure 3-5 CUST I/O cable ....................
  • Page 84 10-019116-01EN, Rev. 4, September 2022 List of Figures...
  • Page 85: List Of Tables

    10-019116-01EN, Rev. 4, September 2022 List of Tables Table 1 Analyzer features ....................23 Table 2 Dosimeter suppliers ....................35 Table 3 Canadian Approved Dosimeter suppliers ............36 Table 4 Case contents ......................40 Table 5 Optional accessories ....................40 Table 6 Components ......................
  • Page 86 10-019116-01EN, Rev. 4, September 2022 List of Tables...

This manual is also suitable for:

Vanta ix c seriesVanta ix m series

Table of Contents