5.2. Load modes

5.2.1. LCD setting
1) Display and operation
When the LCD shows the above interface, it operates as follows:
Step1: Press the
the
button to enter the load parameters setting interface.
Step 2: Long-press the
Step 3: Press the
Step 4: Press the
2) Load mode list
1**
Timer 1
100
light ON/OFF
the load will be on for 1 hour after
101
sunset
the load will be on for 2 hours after
102
sunset
103
the load will be on for 3~13 hours
~ 113
after sunset
the load will be on for 14 hours
114
after sunset
the load will be on for 15 hours
115
after sunset
116
test mode
117
manual mode (default load ON)
When selecting the load mode as the Light ON/OFF mode, Test mode, and
Manual mode, only the Timer 1 can be set, and the Timer 2 is disabled and
CAUTION
display "2 n ".
button to browse the load parameters on the initial interface, and then press
button to enter the load type interface.
or
button to change the load type.
button to confirm.
MPPT PRO-X 10A | 20A | 30A | 40A
2**
Timer 2
2 n
disabled
the load will be on for 1 hour
201
before sunrise
the load will be on for 2 hours
202
before sunrise
203
the load will be on for 3~13
~213
hours before sunrise
the load will be on for 14 hours
214
before sunrise
the load will be on for 15 hours
215
before sunrise
2 n
disabled
2 n
disabled