1.4520.598 – MIC5 IPE Prim Short Circuit Cyl 9
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 9 in ignition sequence.
1.4520.599 – MIC5 IPE Prim Short Circuit Cyl 10
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 10 in ignition sequence.
1.4520.600 – MIC5 IPE Prim Short Circuit Cyl 11
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 11 in ignition sequence.
1.4520.601 – MIC5 IPE Prim Short Circuit Cyl 12
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 12 in ignition sequence.
1.4520.602 – MIC5 IPE Prim Short Circuit Cyl 13
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 13 in ignition sequence.
1.4520.603 – MIC5 IPE Prim Short Circuit Cyl 14
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 14 in ignition sequence.
1.4520.604 – MIC5 IPE Prim Short Circuit Cyl 15
Red alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 15 in ignition sequence.
98 | Troubleshooting | MS150122/02E 2017-09
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil (→ Page 203).
2. Check ignition coil.