METHOD OF ADJUSTMENTS
4 TPL
@
*5
{© vrso3 CE @
{ vrso4
flo TPR
IDLING CURRENT
(1) Set controls as follows.
POWER Switch
— off (mL)
VOLUME Control
— 0 (min)
SPEAKERS
— off (m)
Temperature
— 15°C ~ 30°C (59°F ~ 86°F)
VR303 and VR304
> min. (©)
(2) Connect DC Voltmeter to the TPL (Lch) and TPR (Rch).
(3) Turn the Power Switch on and rotate VR303 clockwise so that the DC Voltmeter reads 3 mV +0.5 mV DC at the TPL. Follow
the same procedure to VR304 for TPR.