Download Print this page

HANYOUNG NUX HSR-SLD15LR Series Instruction Manual page 2

Slim-type single-phase solid state relay

Advertisement

HSR-SL
Slim-type single-phase Solid State Relay
INSTRUCTION MANUAL
Thank you for purchasing Hanyoung Nux products. Please read the instruction
manual carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can view it any time.
▍ Safety information
Before using the product, please read the safety information thoroughly and use it properly.
Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage
DANGER
• The input/output terminals are subject to electric shock
risk. Never let the input/output terminals come in contact
with your body or conductive substances.
WARNING
• Please read the safety information carefully before the use,
and use the product correctly.
• If there is a possibility that a malfunction or abnormality of
this product may lead to a serious accident, install an
appropriate protection circuit on the outside and plan to
prevent accidents.
• Please supply the rated power voltage, in order to prevent
product breakdowns or malfunctions.
• To prevent electric shocks and malfunctions, do not supply
power until the wiring is completed.
• Please disassemble the product after turning OFF the power.
• Any use of the product other than those specified by the
manufacturer may result in personal injury or property
damage.
• Please use this product after installing it to a panel,
because there is a risk of electric shock.
• 4 - 32 V d.c model signal inputs must be supplied with
an isolated and limited voltage/current or Class2,
SELV power supply.
• Short circuit rated current is 3kA.
▍ Suffix code
■ CE, UL certified products
Model
Code
HSR-SL
□ Slim-type single-phase Solid State Relay
D
Control input
voltage
A
15
Rated load current
25
40
L
Operating load voltage
H
Z
Method of operation
R
S
T
Heat sink & Option
N
1C 1 Point of contact (Unmarked)
point of contact
2C 2 Point of contact (Unmarked) ※CAUTION 2) Only for 15 A
※CAUTION 2) 2 contact : Only available for 15 A items (HSR-SL□15LZS2C, HSR-SL□15HZS2C )
■ S-MARK certified products
Model
Code
HSR-SL
-S Slim-type single-phase Solid State Relay
Control input
D
4 - 32 V d.c.
voltage
15
15 A
Rated load current
25
25 A
40
40 A
L
24 - 240 V a.c. (Low voltage)
Operating load voltage
H
24 - 480 V a.c. (High voltage)
Method of operation
Z
Zero-cross switching (standard product)
S
Integrated heat sink (standard product)
T
Heat sink + Bimetal mounted
Heat sink & Option
No heat sink
N
you must use a heat sink that meets the thermal resistance table.
▍ Connection diagram
■ Load and
■ BI Option spec diagram
input voltage
(60℃, 80℃ bimetal mounted)
wiring diagram
Load voltage
18.5
FUSE
80 ℃ Bimetallic
+
Input voltage
Input voltage
4 - 32 V d.c.
90 - 264 V a.c.
-
210
60 ℃ Bimetallic
LOAD
※ This model does not have a fuse internally.
So we suggest using fast-acting fuse separately on the outside as following pictures.
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil,
Michuhol-gu, Incheon, Korea
TEL : +82-32-876-4697
http://www.hanyoungnux.com
CAUTION
• Please make sure that the product specifications are the
same as you ordered.
• Please use the product in places where corrosive gases
(especially harmful gases, ammonia, etc.) and flammable
gases are not generated.
• Please use the product in places without liquids, oils,
chemicals, steam, dust, salt, iron, etc. (pollution degree 1 or 2).
• Please avoid places where large inductive interference,
static electricity,magnetic noise are generated.
• Please avoid places with heat accumulation caused by
direct sunlight, radiant heat, etc.
• When water enters, short circuit or fire may occur, so
please inspect the product carefully.
• Do not connect anything to the unused terminals.
• For DC types, please wire correctly, after checking the polarity
of the terminals.
• When disposing of the product, treat it as industrial waste.
• Pay attention to the edge of the heat sink, which may be sharp.
• The temperature of the main body and the heat sink may
become extremely high when electric power is applied,
which may cause burns.
• In case of product malfunction, remove only the main body.
• Because the SSR heats up when power is on, the lower the
heat sink and ambient temperatures, the longer the life.
• Note 1) If using a separate heat sink, use one that meets
the thermal resistance table.
Content
4 - 32 V d.c.
90 - 240 V a.c.
15 A
25 A
40 A
24 - 240 V a.c. (Low voltage)
24 - 480 V a.c. (High voltage)
Zero-cross switching (standard product)
Random switching
Integrated heat sink (standard product)
Heat sink + Bimetal mounted
No heat sink
※CAUTION 1) When using a separate heat sink,
you must use a heat sink that meets the thermal resistance table.
Content
※CAUTION 1) When using a separate heat sink,
▍ Equivalent Circuit
L1
210
L2
Input the
PLC etc.
Bimetallic
※ Bimetal specification
-Operating temperature: 60℃ / 80℃
-Temperature tolerance: Display temperature ±5℃
-Rating (resistive load): 3 A or less / 48 V d.c.
1 A or less / 277 V a.c.
▍ Specifications
Model
Rated Load Voltage
Peak Voltage
(Non-repetition)
Rated load current
MC1301KE230302
Surge current 60 Hz
(8.3 ms No repetition)
Surge current 50 Hz
(10 ms No repetition)
Leakage current
Output ON voltage dropping
Rated Voltage
Operating Voltage Range
(ON Voltage)
return voltage (OFF Voltage)
Impedance
Current consumption
Response Time
Insulating Resistance
Dielectric strength
Rated impulse withstand voltage (Uimp)
Vibration resistance
Shock resistance
Storage Temperature
Ambient Temperature
Ambient Humidity
Pollution level grade
bolt tightening torque
Usage
certification
Weight Integrated heat sink (with box)
Weight Heating plate removal (with box)
▍ Dimensions
■ CE, UL certified products
● 15A, 25A
17.4
17.4
22.0
17.4
17.4
20.0
19.2
4.5
4.5
4.5
4.5
22.0
22.4
22.4
22.4
■ S-MARK certified products
● 15A
● 25A
80.42
17.4
17.4
17.4
22.0
20.0
19.2
4.5
4.5
4.5
4.5
22.4
22.4
22.0
22.4
● 40A
17.4
4.5
70.0
▍ Load/Surge current Characteristics
■ Load current Characteristics
● Integrated heat sink
50
40
· HSR-SL□40A
30
25
20
· HSR-SL□25A
15
10
· HSR-SL□15A
-30 -20 0
20 40 60 80 100
Ambient Temperature (℃)
25 ℃
15A
25A
40A
80 ℃
6A
8A
15A
▍ How to install
(~)
+
• Please install HSR in the vertical direction.
50
C1
• Otherwise, production performance
40
may be reduced to less than 50 %.
30
• Since the weight of the product is heavy,
40
install it stably when installing DIN rail
20
18
10
-30 -20 0
20 40 60 80 100
Ambient Temperature (℃)
Vertical direction
C2
-
(~)
Horizontality
direction
▍ Caution
• Since the width of the load output terminal is 10.6mm and the input terminal is 6.8mm,
use a smaller terminal than the standard and tighten it with the rated torque.
• When the product is defective, separate main body and exchange it.
• Use it under temperature 25 ℃ when a real load current is 35 ~ 40 A.
• When 40 A maximum load is used, use 10 SQ wiring. Use clamping unit or lug when tightening it.
• Input terminal wiring
1 X 0.5 mm² (1 X AWG20) or larger
1 X 1.5 mm² (1 X AWG16) or less than 2 X 1.5 mm² (2 X AWG16) 1 X 16 mm² (1 X AWG6) or less than 2 X 6 mm² (2 X AWG10)
HSR-SLD15LR□□ HSR-SLD25LR□□ HSR-SLD40LR□□ HSR-SLA15LR□□ HSR-SLA25LR□□ HSR-SLA40LR□□
Low
HSR-SLD15LZ□□ HSR-SLD25LZ□□ HSR-SLD40LZ□□ HSR-SLA15LZ□□ HSR-SLA25LZ□□ HSR-SLA40LZ□□
HSR-SLD15HR□□ HSR-SLD25HR□□ HSR-SLD40HR□□ HSR-SLA15HR□□ HSR-SLA25HR□□ HSR-SLA40HR□□
High
HSR-SLD15HZ□□ HSR-SLD25HZ□□ HSR-SLD40HZ□□ HSR-SLA15HZ□□ HSR-SLA25HZ□□ HSR-SLA40HZ□□
SLow
HSR-SLD15LZ□-S HSR-SLD25LZ□-S HSR-SLD40LZ□-S
SHigh HSR-SLD15HZ□-S HSR-SLD25HZ□-S HSR-SLD40HZ□-S
Low
24 - 240 V a.c. 50/60 Hz
High
24 - 480 V a.c. 50/60 Hz
Low
High
15 A
25 A
40 A
Low
170 A
260 A
420 A
High
170 A
250 A
370 A
Low
160 A
250 A
400 A
High
160 A
230 A
350 A
Less than 20 mA
Less than 1.6 V (R.M.S)
5 - 24 V d.c.
4 - 32 V d.c.
Less than 3 V
Less than 4 kΩ
Constant current method : Less than 14 mA
1/2 Cycle + 1 ms max. ("R" type below 1 ms)
500 V d.c., 100 MΩ (Between the input / output and case)
2,500 V a.c. (For 1min at 60 ㎐)
10 - 55 Hz, Constant current method : 1.5 mm,X·Y·Z each axis direction for 2 hour
1,000 ㎨, X·Y·Z each axis 3 times
-30 ~ 90 ℃
-30 ~ 80 ℃ (no condensation)
45 ~ 85 % RH
Input terminal: 0.05 Nm / Output terminal: 0.25 Nm
Resistive load
17.4
(EN 60947-4-3)
Approx. 226 g
Approx. 266 g
Approx. 94 g
● 40A
● 2C
(2 Point of contact)
17.4
4.5
17.4
22.4
17.4
17.4
17.4
17.4
2-M3(TAP)
±0.05
2-M3(TAP)
±0.05
±0.05
2-4.0
2-4.0
2-4.0
4.5
4.5
4.5
22.0
22.0
22.0
4.5
4.5
44.4
45.4
44.4
44.4
45.4
45.4
80.42
80.42
4.5
17.4
22.4
17.4
17.4
17.4
17.4
17.4
2-M3(TAP)
2-M3(TAP)
±0.05
±0.05
2-4.0
±0.05
2-4.0
2-4.0
4.5
22.0
4.5
22.0
4.5
4.5
22.0
4.5
44.4
45.4
44.4
45.4
44.4
45.4
80.42
80.42
80.42
■ Surge current Characteristics
※ CAUTION 1
400
Heatsink
load
350
thermal
capacity
300
· HSR-SL□15A
8
resistance
25 A
· HSR-SL□25A
250
6
15A
0.92 ℃/W
· HSR-SL□40A
200
25A
0.71 ℃/W
4
150
40A
0.25 ℃/W
15 A
2
100
-30 -20 0
20 40 60 80 100
50
Ambient Temperature (℃)
0
▍ Installation intervals
1
Air flow
Wiring duct
Wiring duct
Wiring duct
Over 10 ㎜
Over 60 ㎜
Horizontality direction
Over 10 ㎜
Over 100 ㎜
Over 30 ㎜
Wiring duct
Inlet
• Output terminal wiring
1 X 1.5mm² (1 X AWG16) or larger
※ Connect the wiring suitable for the
load current capacity to the output terminal.
1,200 V
15 A
25 A
40 A
170 A
260 A
420 A
170 A
250 A
370 A
160 A
250 A
400 A
160 A
230 A
350 A
100 - 240 V a.c. 50/60 Hz
90 - 264 V a.c. 50/60 Hz
Less than 50 V
Less than 40 kΩ
Less than 14 mA
2,500 V
2 Level
17.4
17.4
Approx. 226 g
Approx. 266 g
[Unit : mm]
● N
(Heating plate removal )
4.5
4.5
44.4
45.4
80.42
17.4
17.4
2-M3(TAP)
2-M3(TAP)
±0.05
2-4.0
4.5
22.0
4.5
44.4
45.4
80.42
2-M3(TAP)
40 A
10
100
1000
Number of Cycle (60 Hz)
• Please make intervals
more than following picture.
FAN
• Please install wiring duct
less than half the height of
the heat sink to prevent
obstruction the flow of air.
• The optimal performance of our
HSR is in the ambient
temperature by 25 ℃ so please
use it lower than 25 ℃
±0.05
2-4.0
22.0

Advertisement

loading

This manual is also suitable for:

Hsr-sld25lr seriesHsr-sld40lr seriesHsr-sla15lr seriesHsr-sla25lr seriesHsr-sla40lr seriesHsr-sld15lz series ... Show all