4.2. Measures to be taken when the Protection Circuit operates

4.2.1. Operation of Power Block Protection Circuit

Protection Circuit operates when power problem occurs in the SMPS.
Part Location
SMPS

4.2.2. Power Protection

The Condition of Power Protection Active.
1) Voltage of SMPS (+5.2 VS) is higher than standards.
Normal Condition Voltage Range : +5.2 VS
2) Over-current occurs to FET. (Over-output or Output short)
3) FET's temperature exceed 150 °C.
4) No supply voltage on GATE DRIVER.
Copyright© 1995-2012 SAMSUNG. All rights reserved.
Pin No.
+5.2 VS (2, 3)
+12 V (12)
CN851
PVDD +17.5 V
(10, 11)
PVDD -17.5 V (6, 7)
Protection Circuit Operation
Open
Short
4. Troubleshooting
Remark
4-5