Advertisement

Quick Links

Uponor Combi Port M-Pro
EN
Installation and operation manual
CD0000259

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Combi Port M-Pro and is the answer not in the manual?

Questions and answers

Summary of Contents for Uponor Combi Port M-Pro

  • Page 1 Uponor Combi Port M-Pro Installation and operation manual CD0000259...
  • Page 2: Table Of Contents

    Pipe-clip-sensor safety temperature limiter......24 7.13 Cold water throttle disc............25 7.14 Hydraulic balancing on the manifold........25 7.15 Filling and flushing..............25 7.16 Tightness testing..............26 7.17 Finishing the installation and hand over........ 26 Uponor Combi Port M-Pro Installation and operation manual...
  • Page 3: Copyright And Disclaimer

    Under no circumstances shall Uponor be liable for any indirect, For any questions or queries, please visit the local Uponor website or special, incidental or consequential damages or loss that result speak to your Uponor representative.
  • Page 4: Preface

    Risk of injury and damage. Ignoring warnings can cause components. personal injury and/or damage to products and other property. Uponor is not liable for damage caused by ignoring the instructions in this document or the applicable building code. Caution! Risk of malfunctions. Ignoring cautions can cause the 2.2 Standards and regulations...
  • Page 5 Business users should contact their supplier and check the terms and conditions of the purchase contract. Do not dispose this product with other commercial waste. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 6: System Description

    SD0000060 3.2 Functional description In the Combi Port M-Pro heat interface unit, the cold water is heated through the heat exchanger. It can cool down which is beneficial for only when required in the flow-through principle via a stainless steel the hygiene.
  • Page 7: Components

    Note The following illustrations show example set-ups for all units. Individual components may vary in appearance. The Combi Port M-Pro units are divided into two groups, for radiator connections (RC) and for underfloor heating (UFH). Combi Port M-Pro RC Combi Port M-Pro RC-TL...
  • Page 8 Combi Port M-Pro RC-RL Combi Port M-Pro RC-TL-RL CD0000253 CD0000252 Item Description Item Description Proportional volume control (PM) Proportional volume control (PM) Cold water throttle disc Cold water throttle disc Plate heat exchanger Plate heat exchanger Hot water meter distance piece...
  • Page 9 Combi Port M-Pro UFH Combi Port M-Pro UFH-TL CD0000228 CD0000230 Item Description Item Description Proportional volume control (PM) Thermostatic hot water temperature limiter (TL) Cold water throttle disc Proportional volume control (PM) Strainer Cold water throttle disc Plate heat exchanger...
  • Page 10 Combi Port M-Pro UFH-TL-Additional Combi Port M-Pro UFH-Additional heating heating CD0000232 CD0000234 Item Description Item Description Thermostatic hot water temperature limiter (TL) Proportional volume control (PM) Proportional volume control (PM) Cold water throttle disc Cold water throttle disc Strainer Strainer...
  • Page 11: Optional Components

    Uponor Smatrix Wave Pulse Uponor Smatrix Base PRO CD0000271 Uponor Smatrix is a fully equipped range of components for room temperature control, optionally via radio or wired. The unique auto- balancing technology eliminates the need for manual balancing of the loops.
  • Page 12: Prepare For Installation

    The limit values can be found in our technical information. The heating water quality must be in accordance to VDI 2035. In case of warranty claims, the report must be presented. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 13: Mechanical Installation

    610 x 840 x 110 630 x (840 + 30 + f) x 115 750 x 1190 x 110 770 x (1190 + 30 + f) x 115 Uponor Combi Port M-Pro Installation and operation manual...
  • Page 14 Tighten the nuts. Item Description Connect all pipes to the screw connections. Wall plug (4 pcs) Mount the included wall plugs in the drilled holes and place the cabinet body in the wall opening. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 15 Tighten the ¾" swivel nuts. CD0000283 Screed baffle plate: The screed baffle is mounted from the front. It has two ends on the top of the finish floor and is visible after assembly. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 16: On-Wall Installation

    Mount the heat interface unit to the wall using the hexagon screws. SI0000276 Place a flat gasket on each of the connection rail ¾" screw Item Description connections. Wall plug (6 pcs) Tighten the ¾" swivel nuts. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 17: Installation Of Optional Components

    Bolts Bolts Distance nut Fasten the distance nuts on the bolts. Fasten the DIN rail with the bolts on the distance nuts. Attach the Uponor Smatrix room controller to the DIN rail. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 18 Mount the distance nuts on the bolts. Washer Fasten the DIN rail with the bolts on the distance nuts. Bolt Attach the Uponor Smatrix controller to the DIN rail. Uponor Base flexiboard room controller including screws Fasten the distance bolts on the distance nuts. Additional information Mount the mounting plate using the washers and the bolts.
  • Page 19: Finishing Installation

    Check that the installation is filled/ flushed and vented. temporarily stop and correct the error. Finish the installation by following these steps: Check the complete installation: 1.1. Make sure that the hydraulics are connected correctly. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 20: Operation

    To open the cold water/primary flow strainer, use internal hot water meter to record water consumption. hexagon (6 mm). CD0000344 CD0000295 The strainer collects dirt and its filter can be removed for inspection and cleaning. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 21: Thermostatic Lead Module (Bp) (Optional)

    Combi Port M-Pro RC 1.2. If the valve tip is limited in an upward direction (valve can be closed), only one locking tab needs be to removed.
  • Page 22: Thermostatic Regulated Mixed Circuit

    2,5 bar. The thermostatically regulated, mixed injection circuit provides control For the Combi Port M-Pro RC, the differential pressure regulator is of the temperature in the secondary heating circuit. The following installed in the primary heating circuit to ensure the hydraulic overview shows the position of the components.
  • Page 23 The constant mode (Δp-c) is positioned to the right of the centre position. Constant speed I, II, III: The constant speed mode is positioned to the right of the centre position. Q/l/s Q/lgpm Uponor Combi Port M-Pro Installation and operation manual...
  • Page 24: Zone Valve

    Close the reset: 45 °C +/- 4 K • Fasten and attach to the pipe with an oil flex cable 110 mm, 2 x 0,75 mm², length 1000 mm. • Protect supply cable ends with ferrules. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 25: Cold Water Throttle Disc

    Brown Black Purple Replacing the throttle disc Uponor floor heating calculations Uponor Fußbodenheizungsberechnung Uponor vloerverwarmingsberekening Calculation du chauffage par le sol Uponor 1,5 L/min Calcolo riscaldamento a pannelli radianti Uponor Note Room heating circuit data Raum-Heizkreis-Daten Ruimte- en verwarminggroepsgegevens Données des pièces - circuits de chauffage...
  • Page 26: Tightness Testing

    Incorrect finishing of the installation can lead to property damage. Follow these steps and finish the installation: Check the settings. Complete the acceptance/ finishing protocol. Hand over the documentation and the protocol to the homeowner. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 27: Maintenance

    The tapping duration should then be around 1-2 minutes. The water must be allowed to run at least every 7 days for about 1-2 minutes. Uponor Combi Port M-Pro Installation and operation manual...
  • Page 28: Setting Log Heat Interface Units

    GVH-228H-40 (VacInox) Heat meter distance Heat meter line Qn 1,5 installation length, 110 mm x ¾" piece Other components/devices Component Description Type Not used Installer, signature: Installer, in capital letters: Service partner: Uponor Combi Port M-Pro Installation and operation manual...
  • Page 29: Troubleshooting

    Insufficient heating volume flow Check the volume flow during maximum dispensing using heat meters: passes through the heat exchanger Uponor Combi Port M-Pro - 24 approximately 500-600 l/h Uponor Combi Port M-Pro - 40 approximately 800-900 l/h Heat meter type not supported...
  • Page 30 Check that the central heating circuit pump is working and correctly set working Central strainer is dirty Clean the central strainer Heating system is not working Check the heating system correctly Buffer tank is not filled Check the buffer tank filling Uponor Combi Port M-Pro Installation and operation manual...
  • Page 31: Technical Data

    Zone valve for limiting heating flow to apartment Safety temperature limiter Uponor Base flexiboard Room temperature control Heat meter distance piece Zone valve for limiting heating flow to apartment Thermostatic lead module (BP) Strainer Uponor Combi Port M-Pro Installation and operation manual...
  • Page 32: Dimensional Drawings

    10.2 Dimensional drawings In-wall cabinets All dimensions are given in mm. Combi Port M-Pro RC 555.5 82.75 Combi Port M-Pro UFH ZD0000023 1240 1190 1189.5 22.85 555.5 82.75 ZD0000025 1090 23.35 Uponor Combi Port M-Pro Installation and operation manual...
  • Page 33: Hydraulic Schemes

    10.3 Hydraulic schemes Combi Port M-Pro RC ZD0000026 1240 1190 1189.5 22.35 On-wall cabinet Item Description Proportional volume control (PM) Cold water throttle disc Strainer Plate heat exchanger Hot water meter distance piece Sensor pocket heat meter Cold water meter distance piece...
  • Page 34 Combi Port M-Pro RC TL Combi Port M-Pro RC RL Item Description Item Description Proportional volume control (PM) Proportional volume control (PM) Cold water throttle disc Cold water throttle disc Strainer Strainer Plate heat exchanger Plate heat exchanger Hot water meter distance piece...
  • Page 35 Combi port M-Pro RC TL-RL Combi port M-Pro UFH Item Description Item Description Proportional volume control (PM) Proportional volume control (PM) Cold water throttle disc Cold water throttle disc Strainer Strainer Plate heat exchanger Plate heat exchanger Hot water meter distance piece...
  • Page 36 Combi port M-Pro UFH-TL Combi port M-Pro UFH - additional heating Item Description Item Description Proportional volume control (PM) Proportional volume control (PM) Cold water throttle disc Cold water throttle disc Strainer Strainer Plate heat exchanger Plate heat exchanger Hot water meter distance piece...
  • Page 37: Performance Curves

    Combi port M-Pro UFH-TL - additional 10.4 Performance curves heating Pressure drops with 24 plates (15 l/min) Heating side (primary) 0,80 0,70 0,60 0,50 0,40 0,30 0,20 0,10 0,00 1000 DI0000080 Item Description Pressure drop in bar Primary heating demand in litres/hour (l/h), max. 1000 l/h...
  • Page 38 55 °C Return temperature °C Tapping capacity in litres/minute (l/min) 60 °C 65 °C 70 °C 75 °C 80 °C 85 °C Item Description Return temperature °C Tapping capacity in litres/minute (l/min) Uponor Combi Port M-Pro Installation and operation manual...
  • Page 39 • 12 l/min = 0,68 - 0,88 bar • 15 l/min = 0,70 - 0,90 bar • 17 l/min = 0,75 - 0,95 bar • 19 l/min = 1,00 - 1,20 bar Uponor Combi Port M-Pro Installation and operation manual...
  • Page 40: Regulator Flow Settings

    65 °C 70 °C 75 °C 80 °C 85 °C 10.5 Regulator flow settings Combi Port M-Pro RC 1200 1100 1000 ....Δp...
  • Page 41 Item Description Preset 4 Preset 3 Preset 2 Preset 1 Preset 0,6 Outside range Combi Port M-Pro UFH ΔPv kPa 0.278 1000 0.250 0.222 0.194 0.167 0.139 0.111 0.083 0.056 0.028 Number of turns (default settings) Item Description 5 kPa...
  • Page 42 Uponor Combi Port M-Pro Installation and operation manual...
  • Page 43 Uponor Combi Port M-Pro Installation and operation manual...
  • Page 44 Uponor GmbH Industriestraße 56, D-97437 Hassfurt, Germany Uponor reserves the right to change the product portfolio and the 1143303 v1_12-2023_EN related documentation without prior notification, in line with its policy of www.uponor.com Production: Uponor/DCO continuous improvement and development.

Table of Contents