Uponor Clean II Operating Manual
Uponor Clean II Operating Manual

Uponor Clean II Operating Manual

Treatment plant

Advertisement

Quick Links

Uponor Clean II
Treatment Plant
Operating Manual
2/2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clean II and is the answer not in the manual?

Questions and answers

Summary of Contents for Uponor Clean II

  • Page 1 Uponor Clean II Treatment Plant Operating Manual 2/2023...
  • Page 2: Table Of Contents

    Sludge emptying Chemical filling Control centre Indoor display panel Purified Inlet wastewater Uponor Clean II treatment plant for wastewater for up to 10 PE. We reserve the right to make changes. 2 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 3: Overview

    NOTE! PlantCare program uses treatment plants that serves as a discharge point. local network and local web browser. It is not connected to internet. Uponor Clean II Treatment Plant Operating Manual | 3...
  • Page 4: Installation And Dimensional Drawings

    2. Installation and dimensional drawings 2355 1225 1175 max 1m 1916 2135 4 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 5: Technical Information

    (aluminium chloride) Clean extension pipe 560 x 1 m 1057363 3625015 3 pcs, with installation depth > 0,7 m Extension pipe seal 560 1003600 2521817 6 pcs Sampling well 1003559 3625090 Uponor Clean II Treatment Plant Operating Manual | 5...
  • Page 6: Installation

    In a trench dug into clay or cliffy surface, provide drainage to prevent any surface water that enters the trench from collecting and subjecting the tank to pressure. Uponor anchoring system product number 1003563 6 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 7 Use 4 pcs of Uponor anchoring systems (1003563) Connections • Connect the inlet and outlet 110mm pipes • Connect power mains to the connection box Uponor Clean II Treatment Plant Operating Manual | 7...
  • Page 8 • Cut the neck of the shaft with a saw along its middle, • Lift switch cabinet and compressor unit and disconnect marked “offline” the air hoses from their underside and lift them out (PIC 2) 8 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 9 A compressor unit C • Connect the air hoses to the bottom of the switch cabi- • Connect the lids net and compressor unit, and lift them to the riser Uponor Clean II Treatment Plant Operating Manual | 9...
  • Page 10 Wear protective gloves and goggles when handling the chemical. For detailed information on the flocculation chemical, see the enclosed safety data sheet or our website www.uponor.com/fi-fi, www.uponor.com/sv-se. The treatment plant is ready for use. 10 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 11: Setting Up The Wireless Alarm System

    5 min. Start pairing by pressing and holding the OK button for at least 5 seconds. Lock the treatment plant cover. The sewage treatment system is ready for use. Uponor Clean II Treatment Plant Operating Manual | 11...
  • Page 12: Plantcare

    (1). A control centre (2) is located inside the treatment plant. The status of the treatment plant can be read in more detail from the Uponor PlantCare mobile bookmark (3). 12 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 13 AC adapter top, for instance, with a and mount it in a screwdriver tip. Clean II has two kinds of reminder functions; service wall mount. reminders and a sludge emptying reminder. The Info panel has the following functions: The Info panel indicates when it is time to make periodical service (1-year, 3-year or 6-year-service) •...
  • Page 14 _ _ _1, _ _ _2, _ _ _3, __ _4, S_ _5, S_ _6, S_ _7 etc. The test button is released when the display has reached a reading of S_ _5. 14 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 15 6, Sedimentation (None of the components are on). S406 7. Aeration I S407 8. Aeration II S408 After the test period, the display returns to show the batch counter value. The cleaning process returns to normal. Uponor Clean II Treatment Plant Operating Manual | 15...
  • Page 16: Operating Principles

    The cleaning process starts when the water level in the process tank has risen to the starting level. Alarm level An overfill alarm is sent to the display panel if the water 16 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 17 7. Alarm level unit The alarm level unit gives an alarm if the water level in the septic tank exceeds the maximum level. The air hose of the alarm level unit is black. Uponor Clean II Treatment Plant Operating Manual | 17...
  • Page 18 The waiting cycle keeps biological activity alive. 3. Dosage and mixing of the chemical The Uponor Clean II treatment plant has a holiday The flocculation chemical is used to remove automation function. If the start level is not reached phosphorus from the wastewater.
  • Page 19: Maintenance

    • grease, oil or substances that form toxic gases blocked) and no water is flowing from the discharge • petrol, solvents, paints or other flammable or point towards the treatment plant. explosive substances Uponor Clean II Treatment Plant Operating Manual | 19...
  • Page 20 Instructions for sludge emptying The Info panel reminds you to empty the sludge. If necessary, the sludge can be emptied earlier. Only the septic tank is emptied in the Uponor Clean II treatment plant. Empty the septic tank completely. After emptying, it is recommended to fill the septic tank with clean water.
  • Page 21: Malfunction

    Disturbance in the Empty the septic tank sludge cleaning process and reset the counter, see instructions on page 15. Press the multifunction button for more than 10 seconds to acknowledge the reminder Uponor Clean II Treatment Plant Operating Manual | 21...
  • Page 22 Alarm and start level unit If the alarm or start level unit becomes clogged, the blockage can be opened by blowing compressed air into the unit’s air hose. Start the test cycle after the procedure. 22 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 23: Contact Information

    E-mail System Vendor Name Phone Address E-mail System Installer Name Phone Address E-mail Service Company Name Phone Address E-mail Building Authority Name Phone Address E-mail Environmental Authority Name Phone Address E-mail Uponor Clean II Treatment Plant Operating Manual | 23...
  • Page 24: Service Log

    Service Log Date Performer Counter Service/Notes 24 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 25 Date Performer Counter Service/Notes Uponor Clean II Treatment Plant Operating Manual | 25...
  • Page 26 Date Performer Counter Service/Notes 26 | Uponor Clean II Treatment Plant Operating Manual...
  • Page 27 Date Performer Counter Service/Notes Uponor Clean II Treatment Plant Operating Manual | 27...
  • Page 28 Uponor Infra Oy www.uponor.com/fi-fi www.uponor.com/sv-se www.uponor.com/nb-no We reserve the right to make changes 30716-EN-02-23_022023...

This manual is also suitable for:

1133828