Parameter
Display
F07-19
EtherNet/IP Torque
Scale Factor
F07-20
EtherNet/IP Power
Scaling Factor
F07-21
EtherNet/IP Voltage
Scale Factor
F07-22
EtherNet/IP Time
Scaling
F07-23 to
DOA116 (1 to 10)
F07-32*
F07-33 to
DIA166 (1 to 10)
F07-42*
F07-60
PZD1 Write (Control
Word)
F07-61
PZD2 Write (Frequency
Reference)
F07-62 to
PZD3 to 10 Write
F07-69
F07-70
PZD1 Read (Control
Word)
F07-71
PZD2 Read (Output
Frequency)
F07-71 to
PZD3 to 10 Read
F07-79
* The SI-EP3 ProfiNET option card is limited to F07-23 to F07-27 (DOA116 1 to 5) and F07-33 to F07-37 (DIA166 1 to 5).
Function
Scaling factor for EtherNet/IP torque monitor
Scaling factor for EtherNet/IP power monitor
Scaling factor for EtherNet/IP voltage monitor
Scaling factor for EtherNet/IP time monitor
Dynamic parameters that contain the Modbus
addresses used for programmable registers in
the output assembly 116. Data residing in
bites 20 to 39 of assembly 116 will be written
to the respective Modbus registers identified
by the addresses contained in these
parameters. No data is written to the Modbus
registers if the parameter setting is 0.
Dynamic parameters that contain the Modbus
addresses used for programmable registers in
the input assembly 166. Data residing in the
Modbus registers will be written to the
respective assembly 166 bytes 20 to 39. The
Modbus registers are identified by the
addresses contained in these parameters. No
data is written to the programmable registers
if the parameter setting is 0.
For Profibus, this sets the Modbus address for
PZD1 (PPO output). PZD1 (PPO output)
functions as the STW when F07-60 = 0 to 2.
For Profibus, this sets the Modbus address for
PZD2 (PPO output). PZD2 (PPO output)
functions as the HSW when F07-61 = 0 to 2.
For Profibus, this sets the Modbus address for
PZD3 to 10 (PPO output). A setting of 0, 1, or
2 will disable the PZD3 to 10 (PPO output)
write operation to the Modbus register.
For Profibus, this sets the Modbus address for
PZD1 (PPO input). PZD1 (PPO input)
functions as the ZSW when F07-70 = 0.
For Profibus, this sets the Modbus address for
PZD2 (PPO input). PZD2 (PPO input)
functions as the HIW when F07-71 = 0.
For Profibus, this sets the Modbus address for
PZD3 to 10 (PPO input). A setting of 0 will
disable the PZD3 to 10 (PPO input) read
operation from the Modbus register.
Range
-15–15
-15–15
-15–15
-15–15
Modbus Address
0x- - - -
Modbus Address
0x- - - -
Modbus Address
0x- - - -
Modbus Address
0x- - - -
Modbus Address
0x- - - -
Modbus Address
0x- - - -
Modbus Address
0x- - - -
Modbus Address
0x- - - -
IMPULSE•G+/VG+ Series 5 Technical Manual
Default
0
0
0
0
0
0
0
0
0
0
0
0
August 2023
Page 167