Summary of Contents for SBI CW2900
Page 1
FUEL: CORDWOOD TEST STANDARD: EPA MODEL: CW2900 WOOD INSERT Notice to reader: Our CW2900 wood insert was tested as part of our 2.3 Series (Escape 1800) firebox. Therefore, the 2.3 Series (Escape 1800) is referenced throughout the attached test report.
Page 2
LISTING REPORT FOR APPLICANT ISSUED: Nov 30 2017 11:01AM INSPECTION TESTS AND EVALUATION OF SBI - Series 2.3 Escape 1800 Emissions and Efficiency (35697) RENDERED TO Stove Builder International Inc. 250, rue de Copenhague St-Augustin-de-Desmaures, QC G3A 2H3 Canada GENERAL: This report gives the results of the inspection, tests and evaluation of the above for compliance with applicable requirements of the following standards: CSA B415.1 (2010), ASTM E2515...
Page 3
Stove Builder International Inc. (Laguadeloupe) Contact: Claude Pare Phone: 418-878-3040 ext 255 Fax: 418-878-3001 Email: cpare@sbi-international.com Parties Authorized to Apply Mark: Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 2 of 245...
Page 4
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM PRODUCT DESCRIPTION Product Covered: SBI - Series 2.3 Escape 1800 Emissions and Efficiency Product Description: Product covered: Series 2.3 wood Fuel Room Heaters Final emission results are as follows:...
Page 5
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM DRAWING INDEX Certificate of Conformity - Series 2.3 Escape 1800 Adjustable Burn Rate Wood Burning Heater Emissions & Efficiency Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 4 of 245...
Page 6
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Certificate of Conformity - Series 2.3 Escape 1800 Adjustable Burn Rate Wood Burning Heater Emissions & Efficiency Certificate of Conformity Emissions – Adjustable Burn Rate Wood Burning Heater EPA 40 CFR Part 60, Subpart AAA, ASTM E2515-2011, CSA B415.1-2010 Certificate number: WHI17 –...
Page 7
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM MANUFACTURING INFORMATION Product Covered The series 2.3 -Escape 1800 is constructed of sheet steel. Proprietary drawings and manufacturing methods are on file at Intertek in 1829 32nd Avenue Montreal (Lachine), QC Canada H8T 3J1 and in the EPA filing system. The Escape 1800 is a freestanding wood burning stove constructed of carbon steel from the 2.3 Series.
Page 8
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM SIGNATURE PAGE Reported By: Reviewed By: Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 7 of 245...
Page 9
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM DRAWING INDEX 100 - Owner's manual ESCAPE 1800 200 - Label Escape 1800 300 - Drawings Escape 1800 Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 8 of 245...
Page 10
250, rue de Copenhague, St-Augustin-de-Desmaures (Quebec) Canada G3A 2H3 After-sale service: 418-908-8002 E-mail: tech@sbi-international.com This manual is available for free download on the manufacturer’s web site. It is a copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual obtained from unauthorized sources.
Page 11
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (2 of 59) Installation and Operation Manual for Escape 1800 THANK YOU FOR CHOOSING THIS DROLET WOOD STOVE As one of North America’s largest and most respected wood stove and fireplace manufacturers, Stove Builder International takes pride in the quality and performance of all its products.
Zone Heating and How to Make it Work for You .............. 10 The Benefits of Low Emissions and High Efficiency ............10 The SBI Commitment to You and the Environment ............11 2.5.1 What is Your New Stove Made Of? ................11 Fuel ........................
Page 13
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (4 of 59) Installation and Operation Manual for Escape 1800 5.1.5 Cleaning and Painting the Stove .................. 27 Chimney and Chimney Connector Maintenance.............. 27 5.2.1 Why Chimney Cleaning is Necessary ................
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (5 of 59) Installation and Operation Manual for Escape 1800 PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety Information 1.1 Summary of Operation and Maintenance Cautions and Warnings •...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (6 of 59) Installation and Operation Manual for Escape 1800 General Information on Escape 1800 DB03105 Escape 1800 - On pedestal - black door 2.1 Appliance performance Fuel type Dry cordwood...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (7 of 59) Installation and Operation Manual for Escape 1800 2.2 General Features Maximum log length 20 in (508 mm) east-west* Flue outlet diameter 6 in (152 mm) Recommended connector pipe diameter...
Page 17
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (8 of 59) Installation and Operation Manual for Escape 1800 Models on pedestal Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 16 of 245...
Page 18
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (9 of 59) Installation and Operation Manual for Escape 1800 Model on legs Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 17 of 245...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (10 of 59) Installation and Operation Manual for Escape 1800 2.3 Zone Heating and How to Make it Work for You Your new Escape 1800 wood stove is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature.
2.5 The SBI Commitment to You and the Environment The SBI team are committed to protecting the environment, so we do everything we can to use only materials in our products that will have no lasting negative impact on the environment.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (12 of 59) Installation and Operation Manual for Escape 1800 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, WASTE, COAL OR CHARCOAL, •...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (13 of 59) Installation and Operation Manual for Escape 1800 3.2.3 Log Length Logs should be cut about 1” (25 mm) shorter than the firebox so they fit in easily. Pieces that are even slightly too long make loading the stove very difficult.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (14 of 59) Installation and Operation Manual for Escape 1800 3.2.5 How to Dry Firewood Firewood that is not dry enough to burn is the cause of most complaints about wood stoves.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (15 of 59) Installation and Operation Manual for Escape 1800 3.2.6 Judging Firewood Moisture Content You can find out if some firewood is dry enough to burn by using these guidelines: cracks form at the ends of logs as they dry •...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (16 of 59) Installation and Operation Manual for Escape 1800 4 Operating Your Stove 4.1 Your First Fires Two things will happen as you burn your first few fires; the paint cures and the internal components of the stove are conditioned.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (17 of 59) Installation and Operation Manual for Escape 1800 4.2.2 Conventional Fire Starting The conventional way to build a wood fire is to bunch up 5 to 10 sheets of plain newspaper and place them in the firebox.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (18 of 59) Installation and Operation Manual for Escape 1800 4.3 Maintaining Wood Fires 4.3.1 General Advice Wood heating with a space heater is very different than other forms of heating. There will be variations in the temperature in different parts of the house and there will be variations in temperature throughout the day and night.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (19 of 59) Installation and Operation Manual for Escape 1800 dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (20 of 59) Installation and Operation Manual for Escape 1800 4.3.4 Firing Each New Load Hot Place the new load of wood on and behind the charcoal, and not too close to the glass. Close the door and open the air control fully.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (21 of 59) Installation and Operation Manual for Escape 1800 correct air control use, the flames should slow down, but should stay large and steady, even as the air supply is reduced.
Page 31
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (22 of 59) Installation and Operation Manual for Escape 1800 4.3.6.3 High Output Fires for Cold Weather When the heat demand is high during cold weather, you’ll need a fire that burns steadily and brightly.
Page 32
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (23 of 59) Installation and Operation Manual for Escape 1800 4.3.6.5 North-South Fires Versus East-West Fires In fireboxes that are roughly square, wood can be loaded so that looking through the glass door you see the ends of the logs (north-south) or the sides of the logs (east-west).
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (24 of 59) Installation and Operation Manual for Escape 1800 5 Maintaining Your Wood Heating System 5.1 Stove Maintenance Your new stove will give many years of reliable service if you use and maintain it correctly. Some of the internal components of the firebox, such as firebricks, baffles and air tubes, will wear over time under intense heat.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (25 of 59) Installation and Operation Manual for Escape 1800 5.1.2 Door adjustment 1. Unscrew the nut. 2. Remove the door latch and the key path pin (B). 3.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (26 of 59) Installation and Operation Manual for Escape 1800 Then use the screwdriver to scrape the old gasket adhesive from the door. Now run a 1/4” (6 mm) bead of high temperature silicone in the door gasket groove.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (27 of 59) Installation and Operation Manual for Escape 1800 Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (28 of 59) Installation and Operation Manual for Escape 1800 5.2.3 Cleaning the Chimney Chimney cleaning can be a difficult and dangerous job.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (29 of 59) Installation and Operation Manual for Escape 1800 PART B - INSTALLATION 6 Safety Information 6.1 Summary of Installation Cautions and Warnings ·...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (30 of 59) Installation and Operation Manual for Escape 1800 6.2 Regulations Covering Stove Installation When installed and operated as described in these instructions, the Escape 1800 wood stove is suitable for use as a freestanding heater in residential installations.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (31 of 59) Installation and Operation Manual for Escape 1800 7.2 Clearances to Walls and Ceiling The clearances to combustible walls may be slightly different in Canada and the U.S.A. and may also differ depending on whether you use single or double wall flue pipe.
Page 41
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (32 of 59) Installation and Operation Manual for Escape 1800 Clearances with ceiling (L) lowered to 76" (193 cm) APPLIANCE CLEARANCES APPLIANCE CLEARANCES (INSTALLATION WITH SINGLE (INSTALLATION WITH DOUBLE...
Page 42
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (33 of 59) Installation and Operation Manual for Escape 1800 Clearances for mobile homes MOBILE HOME APPLIANCE CLEARANCES (INSTALLATION WITH DOUBLE WALL PIPE CONNECTOR) CANADA 14"...
Page 43
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (34 of 59) Installation and Operation Manual for Escape 1800 Clearances to combustible materials and floor protection Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 42 of 245...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (35 of 59) Installation and Operation Manual for Escape 1800 7.3 Floor protector Your stove is designed to keep the floor from overheating. It should be placed on a non combustible surface to protect the floor of hot embers that could fall from the stove during loading and maintenance.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (36 of 59) Installation and Operation Manual for Escape 1800 7.4 Reducing Wall and Ceiling Clearances Safely It is often desirable to reduce minimum installation clearances by placing the stove...
Page 46
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (37 of 59) Installation and Operation Manual for Escape 1800 Clearances for shield construction Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 45 of 245...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (38 of 59) Installation and Operation Manual for Escape 1800 7.4.2 Table of Clearance Reduction Percentages Clearances may be reduced by these percentages Sides Top %...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (39 of 59) Installation and Operation Manual for Escape 1800 8 The Venting System 8.1 General The venting system, made up of the chimney and the connecting pipe between the stove and the chimney, acts as the engine that drives your wood heating system.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (40 of 59) Installation and Operation Manual for Escape 1800 8.2.1 Factory-built Metal Chimneys These are sometimes referred to as ‘high temp’...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (41 of 59) Installation and Operation Manual for Escape 1800 8.2.3 Masonry Chimneys The stove may also be connected to a masonry chimney, provided...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (42 of 59) Installation and Operation Manual for Escape 1800 8.4 The Relationship Between the Chimney and the House Because the venting system is the engine that drives the wood heating system, it must have the right characteristics.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (43 of 59) Installation and Operation Manual for Escape 1800 8.4.2 Why the chimney should penetrate the highest heated space When it is cold outside, the warm air in the house is buoyant so it tends to rise. This tendency of warm air to rise creates a slight pressure difference in the house.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (44 of 59) Installation and Operation Manual for Escape 1800 8.5.1 Combustion Air Supply in Mobile Homes Only a wood stove certified and labelled as ‘mobile home approved’ may be installed in a mobile home.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (45 of 59) Installation and Operation Manual for Escape 1800 8.6.1 Installation of Single Wall Chimney Connector The chimney connector assembly has been called ‘the weak link’ in the safety of wood heating systems because failure to install the connector properly (which has been common in the past) can result in house fires.
Page 55
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (46 of 59) Installation and Operation Manual for Escape 1800 The rules below are based on those found in the CSA B365 installation code. Please carefully follow these installation instruction rules, or those enforced where you live.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (47 of 59) Installation and Operation Manual for Escape 1800 Appendix 1: Installing the Legs (DB03105 Only) The leg kit must be assembled to the firebox before positioning the stove. See installation instructions below: 1- Remove the firebricks, the ash dump plug and the loading door from the...
Page 57
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (48 of 59) Installation and Operation Manual for Escape 1800 4- Gently flip the stove back on its legs making sure not to put too much weight on the rear legs.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (49 of 59) Installation and Operation Manual for Escape 1800 Appendix 2: Installing the Optional Fresh Air Intake Kit (AC01336) This mobile home approved stove requires installation of a fresh air intake kit (A) and an insulated fresh air intake pipe (B), sold separately.
Page 59
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (50 of 59) Installation and Operation Manual for Escape 1800 Installation on the back for models on pedestal (AC01336): Installation on the back for models on legs (AC01316): Stove Builder International Inc.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (51 of 59) Installation and Operation Manual for Escape 1800 Appendix 3: Use and Installation of the Optional Blower and Thermodisc An optional blower may be installed on the back of the stove to increase the flow of air past heat exchange surfaces and to help circulate warm air in the room.
Page 61
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (52 of 59) Installation and Operation Manual for Escape 1800 Characteristics of the thermodisc: · Starts the blower when the stove’s temperature reaches 43 °C (110 °F). ·...
Page 62
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (53 of 59) Installation and Operation Manual for Escape 1800 CAUTION: ENSURE THAT THE BLOWER’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE STOVE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (54 of 59) Installation and Operation Manual for Escape 1800 Appendix 4: Installation of Secondary Air Tubes and Baffle 1- Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear right channel hole.
Page 64
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (55 of 59) Installation and Operation Manual for Escape 1800 Note that secondary air tubes (B) can be replaced without removing the baffle board (A). Important Notes: The air tubes are identified for placement as follows: Model...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (56 of 59) Installation and Operation Manual for Escape 1800 Appendix 5: Exploded Diagram and Parts List DB03105 Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 64 of 245...
Page 66
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (57 of 59) Installation and Operation Manual for Escape 1800 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrade or availability.
Page 67
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (58 of 59) Installation and Operation Manual for Escape 1800 Item Description 33 99999 BUILD TO ORDER 34 PL53664 AIR CONTROL COVER 35 SE08304-03 ASH DRAWER 36 PL65577...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 100 - Owner's manual ESCAPE 1800 (59 of 59) Installation and Operation Manual for Escape 1800 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory.
Page 69
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM 200 - Label Escape 1800 Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 68 of 245...
Page 70
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 184 of 245...
Page 71
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (2 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 185 of 245...
Page 72
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (3 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 186 of 245...
Page 73
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (4 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 187 of 245...
Page 74
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (5 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 188 of 245...
Page 75
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (6 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 189 of 245...
Page 76
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (7 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 190 of 245...
Page 77
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (8 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 191 of 245...
Page 78
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (9 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 192 of 245...
Page 79
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (10 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 193 of 245...
Page 80
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (11 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 194 of 245...
Page 81
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (12 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 195 of 245...
Page 82
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (13 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 196 of 245...
Page 83
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (14 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 197 of 245...
Page 84
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (15 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 198 of 245...
Page 85
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (16 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 199 of 245...
Page 86
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (17 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 200 of 245...
Page 87
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Appendix I - EPA correspondence (18 of 18) Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 201 of 245...
Page 88
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 REPORT NUMBER: 103124842MTL-001 REPORT DATE: 21 July 2017 EVALUATION CENTER Intertek Testing Services NA Inc. 1829 32 Avenue Montreal (Lachine), QC Canada H8T 3J1 RENDERED TO Stove Builder International Inc.
Page 89
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (2 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 2 of 15 Contents• INTRODUCTION ........................ 4 PURPOSE OF TEST ..........................4 LABORATORY ...........................
Page 90
November 29-2017 Addition of the deviation from standards agreed upon between EPA and SBI as described in Appendix I of the full test report See section II.B(2). Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (4 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 4 of 15 INTRODUCTION• Intertek Testing Services NA (Intertek) has conducted testing for Stove Builder International Inc., on model Series 2.3 –...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (5 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 5 of 15 Proprietary drawings and manufacturing methods are on file at Intertek located at 1829 32nd Avenue Montreal (Lachine), QC Canada H8T 3J1 and in the EPA filing system.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (6 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 6 of 15 stoves, the test was conducted in accordance with WK47329-14 - Standard Test Method for Determining Particulate Matter Emissions from Wood Heaters using Cordwood Test Fuel.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (7 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 7 of 15 II.C• SUMMARY•OF•TEST•RESULTS• • The appliance tests resulted in the following performance: Particulate Emissions: 1.54 g/hr Carbon Monoxide Emissions: 89 g/hr Heating Efficiency: 69% (Higher Heating Value Basis)
Page 95
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (8 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 8 of 15 July 2017 July 1.85 5.45 2017 •...
Page 96
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (9 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 9 of 15 TABLE•4.•-•DILUTION•TUNNEL•FLOW•RATE•MEASUREMENTS•AND•SAMPLING•DATA••• Sample Volume Particulate Catch Burn Volumetric Ave.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (10 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 10 of 15 III.• PROCESS•DESCRIPTION• III.A• TEST•SET-UP•DESCRIPTON• A 6” flue is connected to a standard 6” diameter vertical single wall pipe and insulated chimney system was installed to 15’...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (11 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 11 of 15 IV.A.(1)• •DILUTION•TUNNEL• Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy Page 212 of 245...
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (12 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 12 of 15 IV.B.• OPERATIONAL•DRAWINGS• IV.B.(1).•••••DILUTION•TUNNEL•SAMPLE•SYSTEMS• IV.B. OPERATIONAL DRAWINGS IV.B.(1).
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (13 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 13 of 15 V.•SAMPLING•METHODS• V.A.••PARTICULATE•SAMPLING• Particulates were sampled in strict accordance with ASTM E2515-2011. This method uses two identical sampling systems with Pall TX-40 binder free, 47-mm diameter filters.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (14 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 14 of 15 VI.A.(2).• STACK•SAMPLE•ROTAMETER• The stack sample rotometer is checked by running three tests at each flow rate used during the test program.
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Test report #103124842MTL-001 (15 of 15) Stove Builder International Inc. Date: 21 July 2017 Project No. G103124842 Page 15 of 15 VI.B.(2).• TUNNEL•VELOCITY/FLOW•MEASUREMENT• The tunnel velocity is calculated from a center point Pitot tube signal multiplied by an adjustment factor.
Page 103
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM COMPONENTS ETL Mark Minimum Labeling Requirements (new Intertek Mark) MINIMUM MARKING REQUIREMENTS FOR PRODUCTS BEARING THE ETL MARK The ETL Listing Mark consists of the following four items: 1.
Page 104
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM manufacture the Listed product(s) in accordance with the specifications information stated herein. The Intertek Field Representative shall determine that the product is manufactured in accordance with this Report and that certification procedures are followed.
Page 105
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Authorized - Authorized by Intertek. All inquiries regarding change to Listed products must be presented to Intertek in writing for consideration and approval. C.S.A. - Canadian Standards Association. Certified - Equipment or material included in a list published by a nationally recognized certification agency that conducts periodic inspections of production of Listed equipment or materials and whose listing stated either that the equipment or material meets recognized standards or has been...
Page 106
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Shipping - As practically as possible, each Listed product is to be shipped completely assembled and incorporate the necessary safety and installation instructions. Standards - The Manufacturer shall have in his possession all the current standards/specifications for the Listed product.
Page 107
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM well as proper handling of the Intertek Certification Mark and the use of log sheets, where applicable. 4. The duties of the Controller of the Intertek Certification Mark are properly understood. Equipment or Supplies Needed 1.
Page 108
Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM Discrepancies - The Intertek Field Representative shall complete his Follow-up Service Inspection sheet detailing the discrepancy and issue a Variance Report. A signature on the Intertek Field Representative's copy shall be obtained from the Applicant's representative, giving evidence that they were issued a copy.