1.) INSTALLATION INSTRUCTIONS

IMPORTANT – READ ALL INSTRUCTIONS BEFORE OPERATING
NOTE: For generator measurements, refer to Installation Data Drawing attached. For
interpretation of numbered items, refer to Parts Legend Drawing attached. Ambient
temperature around this unit must not exceed 105°F.
1.1) INSTALLATION INSTRUCTIONS: (CLEANER) (PORTABLE)
Set STEAM GENERATOR on level floor and attach Solution Bucket (#25) into the 2
predrilled holes on right side of generator.
CONNECTIONS:
Periodically check all plumbing and electrical connections for tightness; this should also be done
before initial start-up.
ELECTRICAL:
This generator must be connected to a disconnect switch protected by fuses or
a circuit breaker with the proper size wire by a licensed electrician in
accordance with N.E.C. and your local codes – Voltage, KW, and Phase
requirement are marked on the nameplate.
WATER SUPPLY:
Connect city water line to Y-Strainer (#6).
Purity: NOT to exceed 26,000 OHMS per CM
Temperature Range: 32°F - 140°F or 0°C - 60°C.
Pressure Range: 20PSI - 150PSI.
*CAUTION:
micron cartridge filter should be installed in the water supply line.
STEAM OUTLET:
Connect the 1/4" Union "Female End" (A) on the Steam Hose (I) from the Steam Gun to the
Steam Outlet (1/4" Union "Male End") (#16).
SAFETY VALVE & DRAIN:
Route Safety Valve (#18) and Manual Drain (#19) separately towards the floor.
LITTLE GIANT "LG-SERIES" (Cleaner) (Portable)
The Pump (#8) requires clean tap water. If the water is not free of foreign matter, a 5
4 of 29
Electro-Steam Generator Corp.
rev. 12102018