Calculations & Data Sheets; Heater Power & Voltage Ratings; Total Power Rating Calculations - ElectroSteam LB-40(C) User, Installation & Maintenance Manual

Portable cleaner
Table of Contents

Advertisement

LB-40(C) thru LB-60(C) (Portable) - User Manual
4.) CALCULATIONS AND DATA SHEETS
4.1) HEATER POWER & VOLTAGE RATINGS
LB 40-60 Model units use 2 Heaters to meet the required (KW) POWER from the
customer's specified INPUT VOLTAGE. Each heater comes in 3 different (KW) POWER
RATINGS and 4 different VOLTAGE RATINGS.
NOTE: SINGLE PHASE is NOT usually OFFERED for 40KW+ generators, because of
the extra cost to run and build with the higher amp draw requirements. Although not offered, in
some special cases single phase 40KW+ generators can be made.
AVAILABLE HEATER RATINGS
KW
20
208
25
208
30
208
HEATER VOLTAGE RATINGS per INPUT VOLTAGE (VOLTS)
Input Voltage 208 220 230 240 380 400 415 425 440 460 480 550 575 600
LB-40
208
LB-50
208
LB-60
208
NOTE: 380-425V heaters are not usually rated for 380-425V. They are usually 208-240V heaters
that have been re-stamped 380-425V and jumpered in series.

4.2) TOTAL POWER RATING CALCULATIONS

The HEATER POWER RATING and NUMBER OF HEATERS are used to calculate the
TOTAL POWER RATING. Since the HEATER POWER RATINGS are in Kilowatts, they
must be multiplied by 1000 to convert them to Watts.
MODEL UNIT
Heater Power Rating (Watts)
X Number of Heaters
Total Power Rating (Watts)
VOLTAGES
230
480
600
230
480
600
230
480
600
230
230
230
230
230
230
230
230
230
POWER RATINGS per MODEL
MODEL UNIT
208
240
240
240
208
230
230
230
208
230
230
230
DEFINITIONS:
P
= Total Power Rating
T
P
= Heater Power Rating
H
x
= Number of Heaters
H
LB-40
20,000
2
40,000
19 of 29
Electro-Steam Generator Corp.
QUAN.
LB-40
LB-50
LB-60
480
480
480
480
480
480
480
480
480
LB-50
LB-60
25,000
2
50,000
KW
2
20
2
25
2
30
600
600
600
600
600
600
600
600
600
30,000
2
60,000
rev. 12102018