User Manual
RPC-2.92
Verification Kit
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
www.rosenberger.com
02CK050-150
Tel.
Germany
Email : info@rosenberger.com
02CK050-150
: +49 8684 18-0
Page
1 / 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 02CK050-150 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rosenberger 02CK050-150

  • Page 1 User Manual 02CK050-150 RPC-2.92 Verification Kit 02CK050-150 Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.com Email : info@rosenberger.com 1 / 19...
  • Page 2: Table Of Contents

    5. Use, Maintenance and Care Connector Care Interface Dimensions and Gauging Mechanical Specifications Handling and Storage 6. Connections Making a Connection Making an Air Line Connection Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.com Email : info@rosenberger.com...
  • Page 3: General Information

    1. General Information This Verification Kit does not contain gauges. So all gauge related chapters are only applicable if additional gauges are available, e.g. Rosenberger 03GK0KS-010 or comparable ones. 1.1 Verification Kit Normal Use Verification Kits are designed as electrical verification standards. Reference measurement values (calibration results) for transmission and reflection are included.
  • Page 4: Kit Contents

    User Manual 02CK050-150 RPC-2.92 Verification Kit 1.3 Kit Contents Table 1-1 Parts of the 02CK050-150 Verification Kit Device Part number Remarks Quantity 20 dB Attenuator 02AS122-K20S3 plug/jack 40 dB Attenuator 02AS122-K40S3 plug/jack Mismatch Airline 02S102-K075 plug/jack Including 50 Ω Center...
  • Page 5: Specifications

    2.2 Electrical and mechanical Specifications Electrical and mechanical specifications are defined for all verification standards in the specific data sheets. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 6: Vna Calibration

    Interpolation. For checking all frequency points with the S2p files use a sweep setting that covers them all precisely, do not use Interpolation. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 7: Rosenberger Hochfrequenztechnik Gmbh & Co. Kg Tel. : +49 8684

    The same measurement error or uncertainty (in linear units) can result in a significant difference for high and low reflect devices when displayed as Return Loss. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 8 Readout the measurement value The other devices of this verification kit can be used in the same way for different measurement situations. Verification of reflection measurements can be done similarly. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 9 Modern VNAs allow to load measurement results (S2P-files) as an extra trace on the VNA screen besides the actual measurement values. This simplifies the comparison of measured and reference values. The full frequency range can be observed in one step. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 10 In case of re-calibration or repair contact your local Rosenberger sales office. Please inform them about any known problem. If there is no local Rosenberger sales office available a request can be set up on the Rosenberger homepage. Please use the search topic “Calibration Request Form” at www.rosenberger.com 4.4 Extent of Rosenberger Re-Calibration Services...
  • Page 11 It is important to take all necessary safety precautions when using chemicals or solvents. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 12 This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial forces generated. NOTE: At no time should the pin depth of the connector be protruding. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 13 By design the center conductors are slightly shorter or maximum equal in length compared to the corresponding outer conductors. 5.2.2 Gauges The Rosenberger gauges are of screw-on type in plug and jack version. They can be used to gauge calibration standards as well as test ports, test port cables, adapters and DUTs. Naming convention: A “gauge plug”...
  • Page 14 Figure 6-1 shows two sets of gauges and gauge blocks for the 3.50 mm and the 2.92 mm connector. Figure 6-1 Connector gauges and gauge blocks for the 3.50 mm and the 2.92 mm connector NOTE: For further Information see user manual 03GK0KS-010 Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 15 • Keep connectors clean. • Do not touch mating plane surfaces. Natural skin oils and microscopic particles of dirt are easily transferred to a connector interface and are very difficult to remove. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 16 8. Make sure the connectors are properly supported. Relieve any side pressure on the connection from long or heavy devices or cables. 9. Final Connection Using a Torque Wrench 10. Use a torque wrench to make a final connection. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 17 After this is overcome the center Air Line conductor slides until the second resistence can be felt. Stop immediately, the center conductor is now in its final position. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 18 Have a look to the female side of the connected Air Line. Often center and outer conductor are not concentric. Do not connect any device now. Use a thin plastic device to center the inner conductor. Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260...
  • Page 19 Rev. Engineering change number Name Date Herbert Babinger 24/04/12 Markus Hantschel 20/06/23 20-1058 Lars Ramtke 20/06/23 Rosenberger Hochfrequenztechnik GmbH & Co. KG Tel. : +49 8684 18-0 Page P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.com Email : info@rosenberger.com 19 / 19...