Carbon Monoxide
Meter
Instruction
Sheet
Introduction
The Carbon Monoxide Meter detects the presence of carbon monoxide
(CO) and measures concentrations
between 1-1000 parts per million (PPM).
The Meter indicates the presence of carbon monoxide in two ways:
.
By a reading on the LCD in PPM.
.
Bya beeper tone.
Safety Information-Read
First
.
Do not use the Meter as a personal safety monitor.
.
Learn and recognize the effects of CQpoisoning.
What the Meter Does
The Meter indicates the presence of CO by a reading on the LCD and a beeper tone.
.
Abov~ 200 PPM, the beeper sounds continuously with the concentration
of CO.
.
From 35 PPM to 200 PPM, the beeper sounds discontinuously with the
concentration
of CO.
eriod
O.C to + 50'C
-30'C to + 60'C
0-99% Relative humidity (non-condensin
0 to 1000PPM
1PPM
1:5% or 1: 10 PPM
<2 seconds
9V, NEDA 1604A or IEC 6LR61, or equivalent.
Meter automatically shuts down after 15 minutes
of inactivity
Stabilized electrochemical
Gas-s
3 years
0-1 PPM
Normal backqround levels.
9PPM
ASH RAE Standard 62-1989 for livinq areas.
50 PPM
OSHA enclosed space 8-hour averaqe level. *
100 PPM
OSHA exposure limit.*
200 PPM
Mild headache, fatique, nausea and dizziness.
800 PPM
Dizziness, nausea and convulsions.
Death within 2 to 3 hours.
*U.S. Department
of Labor, Occupational
Safety & Health Administration
(OSHA) Regulation 1917.24: The CO content in any enclosed space shall be
maintained
at not more than 50 PPM (0.005%).
Remove employees
from
enclosed
space if the CO concentration
exceeds 100 PPM(O.01 %).
Need help?
Do you have a question about the CO1000 and is the answer not in the manual?
Questions and answers