Table of Contents

Advertisement

32

Electrical

The power distribution system used must provide adequate protection against excess line current and
leakage currents to earth.
At 100V AC Input
Parameter
Unit
Input current
Input freq.
Hz
Power
W
Circuit Protection
Each section of the screen should be protected by a Circuit Breaker to protect against high fault currents,
and a Residual Current Device (RCD) to detect earth leakage currents.
Earthing
Each panel is separately connected to the AC power distribution system's earth through the appliance coupler.
All exposed panel metalwork (main frame) is also connected to this earth.
If the framework is earthed only through each panel (i.e. through the panel's mounting bolts), there is a
possibility of electrical damage if a wiring fault occurs, or if an electrical discharge, such as lightning strike,
hits the panels. Under these circumstances, the current discharge path will be through the panel to earth
rather than through the framework to earth. When permanently installed on a metal framework, the framework
itself should be directly connected to earth also.
CE-EMC Statement
This product has been certificated by CE. Installations should be located at least 30 meters from other
sensitive systems or installations and if situated in close proximity to a roadway it may create interference
to vehicle radio communications.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
*Note: Modifications not authorized by the manufacturer may void users authority to operate this device.
Electrical Characteristics for ONE LSAC025 Panel
Rating
Normal
A
16
50-60
1600
Parameter
Max
16
Input current
63
Input freq.
1600
Power
At 240V AC Input
Rating
Unit
Normal
A
16
Hz
50-60
W
3840
B
digital device, pursuant to
Max
16
63
3840

Advertisement